您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 管理学资料 > 结构施工图校审细则(精简版)
结构施工图校审细则目录1编制说明·····················································42审校原则·····················································43常用结构计算分析软件·········································54设计参数(以PMCAD为例)·····································55设计参数(以SATWE为例)······································86地基基础设计(以JCCAD为例)··································137板平法施工图··················································148梁平法施工图··················································169墙、柱平法施工图··············································1710楼梯平法施工图···············································1811基础平面布置图···············································1912地下室结构大样···············································2013结构设计说明·················································2014目录及图签···················································2015计算书·······················································2016归档交验内容·················································211.编制说明:略2.审校原则:略3.常用结构计算分析软件略4.设计参数(以PMCAD为例)4.1▲★设计参数各项正确,与建筑物设计条件相符。4.2▲★楼层组装,总层数和各层层高与建筑核对,特别注意首层层高应算至基础顶(首层地坪有基础拉梁时宜按一标准层计算,拉梁层设为地下室,且拉梁按框架梁设计)。“与基础相连构件最大底标高”数值应正确。4.3▲★计算模型与实际情况相符,模型简化应合理。4.4各标准层梁、柱、墙、洞口等构件布置及截面是否合理;各层混凝土强度是否合理;竖向构件应上下连续、合理分段减小截面(注意建筑立面要求);梁高要考虑建筑外墙窗顶标高和室内净空要求。1)柱布置:柱网布置应力求做到简单、规则、整齐,柱网尺寸应符合经济原则并尽量符合模数。现浇钢筋混凝土民用建筑结构常用柱网6~12米,超过9米不经济。2)梁布置:a、主要承重框架横向布置,可以有效地提高房屋横向的抗侧强度和刚度。这种布置不仅结构上合理,而且建筑上有利于立面处理和室内采光。b、主梁纵横向梁高应区别,截面高度可取跨度的1/10~1/15,且应及时与各专业配合。c、次梁布置尽量将荷载传给主受力框架方向,截面不宜过宽,正常宽度250即可。3)剪力墙布置:a、剪力墙上相关专业预留的较大洞口应按实际计算b、剪力墙的截面厚度应符合墙体稳定验算4)柱、墙、梁的偏心应按实际输入4.5楼板布置,板厚、错层、悬挑板(空调板、雨篷等)、楼板开洞。4.6▲荷载:1)输入荷载是否选取“自动计算板自重”;2)若“考虑活荷载折减”,将与后续SATWE等三维计算、基础导荷所用的活荷载折减同时考虑,因此建议仅在SATWE前处理模块中设置活荷载折减系数;3)楼板恒、活荷载及梁、墙荷载取值正确,人防顶板、非人防顶板荷载区分;4)特殊荷载输入,如吊车、二次装修幕墙、设备安装吊挂、雨棚、网架等。5)楼板上均布的消防车荷载取值见《建筑结构荷载规范》表5.1.1,当楼盖上有覆土时,可对楼面消防车活荷载标准值进行折减,见荷载规范附录B;设计楼面梁时消防车活荷载折减系数见荷载规范5.1.2条;设计基础时可不考虑消防车荷载。6)易遗漏处:a、剪力墙上砌隔墙和门窗洞口隔墙荷载。b、翻边(雨篷、挑檐、下挂板)荷载。c、楼梯多于两跑时应增加恒活荷载、楼梯间按楼板导荷与梯梁梯柱布置是否相符。d、电梯机房层钢梁集中力、电梯机房顶吊钩集中力、多层地下室电梯基坑不落至基础时底坑荷载。e、特殊用途及有重型设备房间荷载(如水箱间、配电间、消防控制室等)。f、板上有集中力(如隔墙、设备基础、屋面台阶、钢梯)时应考虑等效荷载。注意走廊、挑阳台、卫生间、大教室、太阳能屋面等部位的恒、活荷载。如楼板为预制板注意荷载的传导方向。g、地下室顶板覆土荷载,是否应考虑室外景观小品荷载。屋顶花园荷载。h、应考虑屋面、雨篷上积水积雪荷载,对风、雪荷载敏感的结构形式尚应考虑荷载取值的不同及相关参数的放大。i、是否有吊挂荷载。j、屋面为空间网格结构时,不能简单把空间网格结构的支座反力加到主体结构上,应选取合适软件进行组合模型整体计算,判断阵型、位移、扭转、刚度、内力、配筋等参数的合理性并分析采用。5.设计参数(以SATWE为例)5.1▲★设计参数各项取值合理,与统一技术措施相符。1)提前确认建设当地地震局对地震作用计算参数是否有相关要求,如果建设场地有《地震安全性评价报告》,抗震设计时,在小震作用下,分别取规范和“安评”的地震动参数计算,取二者计算所得到的结构底部剪力较大者的楼层水平地震力进行结构抗震验算,中震、大震作用下的结构验算,按规范提供的地震动参数进行。2)建筑物抗震设防及设计要求是否符合特殊行业标准,如中小学校、幼儿园、医院、监狱等。3)注意建筑场地为Ⅲ、Ⅳ类时,对设计基本地震加速度为0.15g和0.30g的地区,宜分别按抗震设防烈度8度和9度时的要求采取抗震构造措施。4)以下情况应考虑竖向地震作用:7.5度(仅高层)、8度、9度时的大跨度和长悬臂结构及9度时的高层建筑。(见高规4.3.2及条文说明、抗规5.1.1及条文说明)。以下情况应考虑以竖向地震为主的荷载组合:7.5度(仅高层)、8度、9度时的大跨度和长悬臂结构。5)建筑物抗震设防类别、设防烈度、设计地震分组、抗震等级;6)校核场地类别、场地土类型;7)是否应考虑重力二阶效应及整体稳定性是否满足要求(见高规5.4节);8)“嵌固端所在层号”,SATWE缺省为地上一层,若±0.00不满足嵌固条件,应调整嵌固端所在层号。满足嵌固条件应符合高规12.2.1条和抗规6.1.14条规定。9)模拟施工和施工次序定义(对一般多、高层建筑采用“模拟施工加载3”;对钢结构及没有层概念的体育场馆类应采用“一次性加载”;对于长悬臂结构或有吊柱结构应采用“一次性加载”进行复核;对全部转换的高层采用模拟施工加载3及在施工次序中把转换层及其以上N层(按高规附录E取)编为一个次序号和模拟施工加载3分别计算取不利;对带转换高层的基础再采用模拟施工加载2的柱底力计算一下。对于悬吊结构与跃层构件按跃层建模时应注意正确的施工顺序);10)“规定水平力”的确定方式,主要计算位移比、倾覆力矩。规范方法适用于大多数结构,节点地震作用CQC组合方法适用于极不规则结构,即楼层概念不清晰,剪力差无法做的结构。11)转换层应指定为薄弱层。12)“对所有楼层强制采用刚性楼板假定”仅用于位移比和周期比计算。13)结构周期应把计算值回代重新计算;14)风荷载和体型系数取值(对风荷载比较敏感的高层建筑,承载力设计时应按基本风压1.1倍采用。门刚规程荷载规范值的1.05倍。舒适度验算风压取十年一遇值);15)计算重力荷载代表值时组合值系数取值(抗规5.1.3条);16)周期折减系数,高规4.3.17条,根据砌体填充墙多少:框架结构0.6~0.7,框架-剪力墙结构0.7~0.8,框架-核心筒结构0.8~0.9,剪力墙结构0.8~1.0;17)结构的阻尼比(根据不同的结构形式取值不同,多遇地震作用下一般钢筋混凝土结构和砌体结构取0.05、不大于12层的钢结构房屋取0.035,大于12层的钢结构房屋取0.02、钢-混凝土混合结构取0.04、预应力混凝土框架结构取0.03、采用隔震或消能技术的结构阻尼比则高于5%有的可以达到10%。详见抗规5.1.5/8.2.2/9.2.5/10.2.8、高规11.3.5/3.7.6、混凝土规范11.8.3、荷载规范8.4.4等);18)活荷载不利布置应考虑;19)考虑柱二阶效应,框架柱按混凝土规范6.2.4条,排架柱按混凝土规范B.0.4,注意排架柱计算长度应按混凝土规范表6.2.20-1调整。20)“梁扭距折减系数”对于现浇楼板结构,采用刚性楼板假定时,可以考虑楼板对梁的抗扭作用而对梁的扭距进行折减,默认折减系数为0.4,但对于结构转换层的边框支梁扭距折减系数不宜小于0.6。如果,单独定义了弹性楼板3、6,可以考虑梁的扭距折减系数0.8左右。21)“考虑P-△效应”对于混凝土结构,待计算完成后,查看结构的质量文件,程序会提示该工程是否计算P-△效应。对于钢结构一般宜考虑P-△效应。22)“按高规或高钢规进行构件设计”高层应勾选,多层不需。勾选则按高规或高钢规进行组合验算,不勾选则按抗规或钢规进行组合验算。5.2▲特殊构件定义校核。1)次梁按主梁输入时,次梁端支座若点铰接计算,应构造上考虑主梁实际受到的扭矩作用予以加强。与剪力墙垂直相交的梁端支座应改铰。2)连梁应判断:跨高比≥5或支承次梁的应指定为普通梁,可考虑调幅。3)局部有转换构件的梁、柱应指定为转换梁、转换柱。4)角柱应定义。5)抗震等级需特殊指定者,如剪力墙结构中转角窗两侧剪力墙、框架结构中局部的大跨度框架、局部转换构件、需提高抗震性能的重点构件等。6)弹性板指定:弹性板6计算楼板平面内和平面外刚度,一般用于板柱-剪力墙结构的;弹性板3假定平面内无限刚,仅计算平面外刚度,一般用于厚板转换层的厚板的;弹性膜计算楼板平面内刚度,平面外刚度为零,其它情况宜采用弹性膜。5.3▲★查看各项结果数据文件,分析其合理性、可靠性、适用性。5.3.1结构设计信息WMASS.OUT1)重点检查前处理信息(见4.1)。2)高层建筑结构的整体稳定是否满足《高层建筑混凝土结构技术规程》JGJ3-2010第5.4.4条。3)框剪结构时,应检查0.2Q0调整是否应分段调整、起止楼层号,(查看结果数据文件,satwe缺省框架柱最大调整系数为2.0、框支柱5.0,按规范要求应按实际剪力比系数调整,如果过大则应考虑结构方案是否合理)。4)检查各楼层单位面积质量分布是否异常,是否存在质量分布明显不均匀或异常的情况。(常规钢筋混凝土结构14~17KN/m2)5)相邻层侧向刚度变化是否符合《高层建筑混凝土结构技术规程》JGJ3-2010中3.5.2规定和《建筑抗震设计规范》GB50011-2010中表3.4.3-2要求,如不符合须采取相应措施。6)多层框架结构应注意《建筑抗震设计规范》5.5.2条第二款之规定,即7~9度时楼层屈服强度系数小于0.5的钢筋混凝土框架和框排架结构,应验算在罕遇地震作用下薄弱层弹塑性变形,弹塑性层间位移角限制1/50。7)检查转换层等效侧向刚度比(该项检查应配合使用高规附录E)。8)检查楼层抗剪承载力比值是否满足《建筑抗震设计规范》第3.4.3-2条,若当结构受剪承载力小于相邻上一楼层的80%时,软件是否已判断为薄弱层,进行地震剪力放大多层1.15(高层1.25)。楼层受剪承载力不应小于其相邻上一层受剪承载力的65%(A级高度建筑)或75%(B级高度建筑)。5.3.2周期震型地震力WZQ.OUT1)检查以扭转为主的第一周期与以平动为主的第一周期之比(A级高度不宜大于0.9,B级高度、混合结构高层和复杂高层不宜大于0.85),第一周
本文标题:结构施工图校审细则(精简版)
链接地址:https://www.777doc.com/doc-6570808 .html