您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > 智能变电站智能控制柜技术规范
ICS29.24029.240.20CEC66-2008国家电网公司企业标准Q/GDW430—2010智能变电站智能控制柜技术规范ThetechnicalspecificationforIntelligentcontrolcabinetinSmartSubstation2010-××-××发布2010-××-××实施国家电网公司发布Q/GDWQ/GDWQ/GDW430—2010I目次前言······························································································································II1范围··························································································································12引用标准····················································································································13使用环境条件··············································································································14技术要求····················································································································15防护等级····················································································································46技术服务····················································································································4编制说明·························································································································5Q/GDW430—2010II前言由于现行国家标准、行业标准、企业标准和IEC标准等未统一智能变电站中智能控制柜的技术要求等内容,为使智能控制柜选型、设备采购等工作有所遵循,特编制本标准。本标准提出的技术性能参数基于国内外变电站智能控制柜的设计、制造和运行经验。由于智能变电站技术仍处于发展阶段,本技术规范的相关技术原则将随着技术的发展与成熟逐步修订和完善。本标准由国家电网公司基建部提出并负责解释。本标准由国家电网公司科技部归口。本规范主要起草单位:四川电力设计咨询有限责任公司,四川电力试验研究院、中国电力工程顾问集团公司、江苏省电力设计院、河南省电力勘测设计院、山东电力工程咨询院有限公司。本规范参与起草单位:浙江省电力设计院、陕西省电力设计院、安徽省电力设计院、国网电力科学研究院、浙江电力试验研究院。本标准主要起草人:吴家林、郑旭、李琪林、陈志蓉、曾健、张国钦、潘峰、秦华、浦知新、李娴、刘中元、张玉军、信珂、黄国方、阮黎翔、刘盛、孝小昂、邵松涛。Q/GDW430—20101智能变电站智能控制柜技术规范1范围本规范规定了智能变电站中智能控制柜的功能要求、安装要求和技术服务等内容。本规范适用于国家电网公司系统内智能变电站的新建工程,其它扩建、改建工程可参照执行。2引用标准下列标准所包含的条文,通过在本规范书中引用而构成本规范书的条文。所示标准均应采用最新有效版本。GB4208—1993外壳防护等级(IP代码)GB/T4797电工电子产品自然环境条件GB/T4798电工电子产品应用环境条件GB/T11022—1999高压开关设备和控制设备标准的共用技术要求GB/T11804电工电子产品环境条件术语GB/T17626电磁兼容试验和测量技术GB/T18663电子设备机械结构公制系列和英制系列的试验GB/T19183电子设备机械结构户外机壳Q/GDW383—2009智能变电站技术导则Q/GDW393—2009110(66)kV~220kV智能变电站设计规范Q/GDW394—2009330kV~750kV智能变电站设计规范IEC61587电子设备机械结构系列3使用环境条件海拔高度:≤1000m;环境温度:−5℃~+45℃(户内);−25℃~+55℃(户外);最大日温差:25K;最大相对湿度:95%(日平均);90%(月平均);大气压力:86kPa~106kPa;抗震能力:水平加速度0.30g,垂直加速度0.15g;注:以上环境条件可根据具体工程调整。4技术要求4.1电源控制柜电源额定电压:AC380/220V,50Hz。4.2控制柜尺寸控制柜尺寸宜按照GB/T19183.2—2003《电子设备机械结构户外机壳第2部分:箱体和机柜的协调尺寸》中尺寸系列的数值选择。控制柜尺寸宜为800(宽度)×600(深度)mm、1000(宽度)×800Q/GDW430—20102(深度)mm,高度视柜内设备情况确定。4.3控制柜结构4.3.1安装于户外的控制柜宜采用双层柜体,两层板材之间距离为25mm。户内控制柜可采用单层柜体。板材厚度不小于1.5mm。4.3.2控制柜应为前后开门,便于设备安装和连接。4.3.3控制柜应留有地脚安装孔。4.3.4控制柜应设有便于产品运输的起吊设施。4.3.5控制柜应设有供调试、检测接线用穿线孔。4.3.6结构组装后应整洁、美观,各焊口应无裂纹、烧穿、咬边、气孔、夹渣等缺陷,并应及时清除焊渣。4.3.7各紧固联接应牢固、可靠,所有紧固件均应具有防腐蚀镀层或涂层,紧固联接应采取防松措施。4.3.8结构各结合处及门的缝隙应匀称,门的开启、关闭应灵活自如,锁紧可靠。门的开启角度应不小于90°。4.3.9控制柜应提供可靠的锁具、铰链及外壳防护。4.3.10控制柜具备防盗性能,所有的装配螺钉应从机柜内部拆卸。4.3.11户外安装的控制柜应安装防雨帽,防止雨水进入柜内。4.4控制柜材料4.4.1控制柜材料宜采用优质冷轧钢板,也可采用复合材料。柜体外表面和内表面宜采用粉末喷涂。对于高污染地区,控制柜材料可采用不锈钢。4.4.2用于控制柜的金属材料应具备抗腐蚀和电化学反应的能力。4.4.3用于控制柜的非金属材料应无脱层、空洞等缺陷。在经腐蚀性液体试验后无应力裂纹、无涂层剥落、无蜕皮、无颜色改变。4.4.4非金属零部件(包括绝缘电线、电缆和发泡材料)应为自熄性材料,其阻燃性应能通过阻燃试验的要求。4.4.5所有外露非金属制件应能抵抗紫外线,经过模拟太阳辐射试验后,无裂纹、针孔、破损等现象。4.5绝缘性能4.5.1绝缘电阻在正常运行条件下,控制柜的外引带电部分和外露非带电金属部分及外壳之间,以及电气上无联系的各回路之间,用1000V直流兆欧表测量其绝缘电阻值,应不低于20MΩ。4.5.2介电强度在正常运行条件下,控制柜能承受交流50Hz、2000V,历时1min工频耐压试验,无击穿闪络及元器件损坏现象。工频试验电压值按表4.5-1选择,也可以采用直流试验电压,其值应为规定工频试验电压的1.4倍。表4.5-1各回路试验电压要求被试回路额定绝缘电压(V)试验电压AC(V)整机引出端子和背板线——地>60~2502000直流输入回路——地>60~2502000信号输出触点——地>60~2501000无电气联系的各回路之间>60~2502000整机带电部分——地≤60500Q/GDW430—201034.5.3冲击电压在正常运行条件下,控制柜的工作电源回路、输出触点等回路对地,以及回路之间,应能承受1.2/50us的标准雷电波的短时冲击电压试验,试验电压为5000V。4.6耐气候性能控制柜应能承受下表中严酷等级1级的气候试验。试验后,用目测检验内部零件,判定是否合格,应无锈蚀、裂纹或其他损坏,无水进入。铰链、锁和把手等应处于工作条件。按照下表中的i项的试验应证明冰霜可能接近内部零件,但没有导致防护等级降低的损坏。表4.6-1环境等级1和等级2的气候条件序号环境参数试验严酷程度持续时间试验方法等级1等级21低温−45℃−65℃16hGB/T2423.12高温80℃90℃16hGB/T2423.23湿热30℃,93%30℃,93%96hGB/T2423.94温度改变速率−50℃~+23℃1℃/min−50℃~+23℃1℃/min2次循环GB/T2423.225太阳辐射1120W/m21120W/m272h,40℃GB/T2423.246凝露40℃90%~100%RH40℃90%~100%RH96hGB/T2423.47降水(雨、雪、冰雹等)IP54IP55-GB42088周围空气运动50m/s60m/s--9冰和霜的形成是是--4.7温湿度调节性能a)控制柜应对柜内温度、湿度具有调节和控制能力。通过调节,柜内最低温度应保持在+5℃以上,柜内最高温度不超过柜外环境最高温度,柜内湿度应保持在90%以下,以满足柜内智能电子设备正常工作的环境条件,避免大气环境的恶劣导致的智能电子设备误动或拒动行为。b)控制柜内应配置加热器,防止柜内出现凝露。c)控制柜顶部应加装隔热材料,阻止太阳辐射对机柜内部的影响。d)控制柜宜采用自然通风方式。柜内空气循环为下进风,上出风。控制柜底座高度应≥100mm,以确保空气流入不受阻。进、出风口内侧应配置可拆卸的滤网。柜内设备布置时应考虑预留风道的位置。在环境温度较高的地区,可配置换气扇进行主动换气。换气扇应采用AC220V供电,振动、噪音及电磁干扰不影响控制柜内智能电子设备的可靠性。e)双层控制柜外壁宜上下不封口,形成自然风冷风道。f)在环境温度寒冷的地区,柜体内六面应铺设阻燃型保温层,保温材料选用导热系数小,比重轻,阻燃,无毒,防水性好和耐腐蚀的产品。f)在环境温度炎热的地区,可在控制柜顶部加装铝散热片,加强传导散热。4.8告警功能控制柜的温度、湿度控制系统应具有告警功能,能够对温度、湿度传感器及控制器执行元件的异常工作状态进行告警。a)报警信号应包括对下述行为的监视:凝露控制器异常、温度控制器异常、加热器异常、换气扇异常等。b)温度控制系统中发生温度传感器、换气扇、低温控制加热器损坏时,温度控制系统应能发出异常告警信息。Q/GDW430—20104c)湿度控制系统中发生湿度传感器、加热器损坏时,湿度控制系统应能发出异常告警信息。4.9机械性能控制柜在经过振动、冲击和碰撞等机械试验后,不应出现下列缺陷:a)出现影响形状、配合和功能的变形或损坏;b)脱层、翘曲、戳穿和永久变形;c)密封部位的膨胀、开裂、脱落;d)安装件、紧固件的弯曲、松动、移位或损坏;e)门、盖板等活动部件转动不灵活、关(锁)不住、卡死。4.10接线、回路布置要求a)控制柜的设计应满足光缆、电缆由柜底引入的要求。b)柜内应配置足够端子排。端子排、电缆夹头、电缆走线槽均应由阻燃型材料制造。端子排的安装位置应便于接线,距柜底不小于300mm,距柜顶不小于150mm。每组端子排应留有不少于端子总量15%的备用端子。端子排上的操作回路引出线与操作电源不能接在相邻的端子上,直流电源正、负极也不能接在相邻端子上。c)控制柜内应留有安装光纤熔接盒的位置。4.11接地控制柜内宜设置截面不小于100mm2的接地铜排,并使用截面不小于100mm2的铜缆和电缆
本文标题:智能变电站智能控制柜技术规范
链接地址:https://www.777doc.com/doc-1297102 .html