1河口水电站2#机组振摆异常原因分析及处理AnalysisandtreatmentaboutvibrationabnormalofUnit2inHekouHydropowerStation孙德敏王仁权湖南五凌电力工程有限公司湖南省长沙市邮编:410004摘要:河口水电站2#机组运行时摆度和振动时大时小,水导瓦温时高时低,噪音较高;上导滑转子盘车位移高达0.14mm(上导抱瓦间隙0.03~0.04mm)。经整体校摆、加工后运行稳定,振摆正常、瓦温正常。Abstract:Theunit2inHekouhydropowerstationthatvibrationsometimesbigsometimessmall,turbineguidebearingpadstemperaturesometimeshighsometimeslowandwithloudnoiseduringunitworking,theupperguidebearingradialdisplacementhighto0.14mmwhenunitrunout(designclearanceis0.03~0.04mm),thevibrationandtemperatureisnormalafteradjustmentandmachining.关键词:振动摆度轴瓦温度上导轴承盘车大轴校摆Keywords:vibrationbearingpadstemperatureupperguidebearingrunoutaxesadjustment1设备简介河口水电站位于四川九龙县子耳乡境内,电站发电机组单机容量18MW,装机台数2台。水轮机型号:HLD358c-LJ-156,转轮直径:1.56m,额定出力18.75MW,额定转速600r/min,额定水头219m。水导轴承承受机组载荷,采用筒式轴承,轴瓦表面采用巴式合金材料,轴瓦表面与轴领间隙为0.15-0.2mm,由油冷器进行冷却,轴承油冷器为分半水箱式结构,位于轴承体下部。发电机采用具有上下两个导轴承的立轴悬式结构,推力轴承置于上机架上,推力轴承与上导轴承共用一个油槽,并采用内循环冷却方式。发电机型号:SF18-10/3250,定子内径2500mm。2缺陷现象2#机组在空转、空载、负荷1.2万kw时,运行平稳,摆度、各部瓦温均在要求范围内,在1.2万kw以上时,机组运行部平稳,摆度、瓦温变化幅度较大,水导瓦温最高达到61℃,下导摆度达到0.27mm。且机组在下午3点~晚上9点运行状态较好,晚上9点以后开始变差。同时,定子铁芯温度单机运行时最高达到91℃,最低也有85℃。表12#机组调试试运行状态表下导摆度水导摆度水导瓦温备注初次开机0.15mm0.22mm56℃空转3小时瓦温稳定试验2初次并网满负荷0.20mm0.24mm56℃(↑上升)18MW并网1h~12h0.27mm0.24mm61℃18MW并网12h之后0.20mm0.22mm58℃18MW并网后4天中(最好)0.18mm(01:00)0.09mm56℃18MW并网后4天中(最差)0.20mm(17:00~18:00)0.20mm58℃18MW3机组主要问题经检查,河口电站2#机主要存在的以下问题:一、机组摆度和振动、水导瓦温时高时低,机组状况不稳定(尤其是上游来浮渣较多时,浮渣冲到水轮机叶片内);二、机组运行声音异常、噪音较大;三、上导滑转子盘车位移过大(盘车时抱上导瓦作为基准,摆度应该在0-0.03mm内,但实际高达0.14mm);四、发电机定子刚进行过重新叠片和下线,可能存在电磁力不平衡。4分析处理过程4.12014年7月,对2#机组进行了轴线检查,发现上导滑转子与轴线不同心。经多次检修盘车,发现上导(盘车时抱上导)的摆度达0.13mm。经测量外径,上导滑转子处直径偏差不大(数据见表2)。初步分析,认为滑转子与轴线不同心,存在倾斜。怀疑产生此现象原因为:滑转子在与大轴热套时,由于配合面毛刺或杂质未清理干净,造成滑转子的中心轴线与大轴轴线交叉不重合。表2上导摆度测量(单位0.01mm)在抱紧上导瓦盘车过程中,上导滑转子倾斜将导致上导出现摆度,并影响其他部位摆度的准确测量。正常情况下,抱瓦部位只存在0.01~0.03mm的径向位移。为验证上导滑转子是否存在倾斜,此次盘车单独测量了上导滑转子上端面的跳动(数据见表3)。跳动值最大达0.27mm,且变化富有规律,基本证实了上导滑转子与轴线不同心,存在倾斜现象。表3上导滑转子上端面跳动(单位0.01mm)4.22014年7月,在未盘车的情况下,以水导瓦为基准,将大轴推到水导瓦中心,重新调整上、下导瓦隙,将上、下导瓦隙以0.15mm进行均放。开机后摆度增大,水导瓦温在61℃稳住,后缓慢下降。4.32014年11月,对2#机组进行了稳定性试验。(1)试验内容:变转速试验、变励磁试验、变负荷试验。点号1#2#3#4#5#6#7#8#+X表数值0694-2-7-8-6+Y表数值-60-1-3-8-13-13-11点号1#2#3#4#5#6#7#8#数值03112227241543(2)试验数据:试验时,上游水位为1944.95m,尾水水位为1700.63m,机组能带100%额定负荷。试验数据详见表4、图1、图2。摆度变化折线图0100200300400500600700初起转25%nr50%nr75%nr空转25%ur50%ur75%ur空载并网1.5MW3MW4.5MW6MW7.5MW9MW10.5MW12MW13.5MW15MW16.5MW18MW推摆+X上摆+Y下摆+Y下摆+X水摆+Y水摆+X图1摆度变化分析图4(3)试验结论:①、机组轴线不太理想。②、机组转动部分存在明显失衡。③、机组存在轻微的磁力不平衡。④、机组在整个带负荷过程中,未发现因水力因素造成的振动、摆度测值增大现象且未发现明显的低频水力振动区。(4)试验结果分析:由上述试验数据可看出,上导摆度无论何种工况摆度值均是最大的,故上导滑转子可能存在问题,与轴线检查结果一致,需进行进一步核实。振动变化折线图0102030405060708090初起转25%nr50%nr75%nr空转25%ur50%ur75%ur空载并网1.5MW3MW4.5MW6MW7.5MW9MW10.5MW12MW13.5MW15MW16.5MW18MW上平+Y上垂+Y上平+X定平+Y下平+Y下平+X顶平+Y顶垂+Y尾压脉动图2振动变化分析图5表4河口电站2号机组运行稳定性试验电测结果汇总表测量值单位:μm工况名称转速(rpm)推摆+X上摆+Y上平+Y上垂+Y上平+X定平+Y下平+Y下平+X下摆+Y下摆+X水摆+Y水摆+X顶平+Y顶垂+Y尾压脉动初起转39.2294.6119.71.55.93.22.33.18.374.569.139.933.86.75.614.825%nr148.5279166.71.63.22.92.33.45.557.56260.255.22.21.515.250%nr302.3379.5249.24.85.15.33.96.211.67382.7102.187.35.4213.875%nr450.6516.1360.1147.614712.422.8109.8113.8154.1131.49.12.913.8空转601.2639.4517.836.615.537.314.730.956.7160.3168.6237209.718.84.8125%ur600609530.837.614.636.413.733.960.9166.3183.1258.8235.220.75.90.850%ur598.7596.8534.737.615.136.313.934.461.2170184258.9238.421.36.9175%ur600591.5534.839.916.238.314.635.461.7176.4187.6259.323722.18.81.1空载600591.5544.340.315.537.113.337.263.8186.9188.9260.4237.423.69.41.4并网600582.8552.442.516.137.914.639.867.4190.9203.2263.6242.225.310.11.71.5MW601.3581.155242.81637.714.439.367.1193.4194.4262.1243.424.7102.13MW600586.4559.943.315.839.514.841.171.3192.4209.7261.823725.710.11.44.5MW601.2581.155843.316.139.714.840.671.2196.7205.8264.8239.425.5102.86MW600584.7558.143.415.639.319.743.271.2190.6211.7258.7236.427.510.61.27.5MW600588.2556.843.415.539.923.343.772.4194.7213.7261.6241.828.310.82.29MW600589.6566.544.116.540.919.545.674.9193.3215.4261.7235.928.811.34.310.5MW600591569.846.816.943.418.544.879.1206.8226.1266.2215.727.710.83.812MW601.3594.1573.54816.844.217.845.281.1214.8223.5269.8208.430.211.73.413.5MW600589.1573.747.716.643.822.249.979.8214.4228269.8210.630.312.32.915MW601.3586.5564.546.416.343.220.446.178212.5219.1275.3218.528.712.3316.5MW600589.7567.344.115.641.619.641.573.5202.3215.6264.5223.224.312.51.118MW600588.9564.844.716.142.319.842.674203.6221.7264.3219.625.412.62.3表5水轮机发电机大轴校摆主要检测数据(单位:0.01mm要求不大于0.03mm)点位部位正面反面1234567812345678推力头端面0000.51.5100.50-1-1010-2-0.5上导滑转子00-0.5-1-1.5-1.5-2-1.500.52-0.5-1-1.510.5下导滑转子-1-1-1-0.50-0.5-0.5-0.500.520.51231水导滑转子000.50.51-0.5-0.5-0.50112111164.42015年2月,由发电机厂家对发电机大轴与水轮机大轴进行了整体校摆。发电机大轴单轴校摆:预先锻造上导滑转子,粗加工后更换上导滑转子,将上导滑转子的紧量值由(+0.06~0.10mm)增加到(+0.15~0.20mm),并在热套后进行配车,配车需要一个较大的车床,满足磁轭直径要求,立车更好,避免在工二次热套出现问题。根据下导滑转子找正,将上导滑转子修车好,并留有0.2mm左右余量,在联轴校摆时修车。同时检测发电机大轴各部位的形位公差符合设计要求,主要包括法兰、法兰止口、法兰外圆,上导下导滑转子。发电机、水轮机大轴联轴校摆:发电机单轴校摆后,主轴热套推力头等部件,装上推力头卡环后,将发电机主轴与水轮机主轴在卧车上连轴找摆,采用一卡两托方式,按相关联轴标准修磨全部跳动到设计要求;主要包括推力头端面、上导滑转子外圆、下导滑转子外圆及大轴联接法兰、水轮机大轴法兰,水轮机与转轮联接止口等进行检测。符合要求后,并重新钻铰连轴法兰处的4个径向销孔,重新配制销钉。尤其要强调的是,端面跳动必须测量轴线的正反两面,且两面均要符合要求。主要检测值见表5
本文标题:河口水电站机组振摆异常原因分析及处理(1120)
链接地址:https://www.777doc.com/doc-2255842 .html