您好,欢迎访问三七文档
目录1概述................................................................11.1编制依据....................................................................11.2工程概况....................................................................11.3换热器明细表.................................................................12试压准备工作........................................................53换热器抽芯..........................................................54换热器清洗..........................................................55试压要求及方法......................................................65.1试压要求....................................................................65.2试压方法....................................................................65.3换热器试压步骤...............................................................76换热器回装、复位....................................................77施工进度计划........................................................88施工手段用料、设备..................................................89安全事项............................................................9中国石油抚顺石化公司原油集中加工、炼油结构调整技术改造工程30万吨/年酮苯脱蜡装置换热器抽芯试压方案第1页共9页1概述1.1编制依据1.1.1中国石油集团工程设计有限责任公司抚顺分公司《30×104t/a酮苯脱蜡装置基础设计》(讨论稿)。1.1.2抚顺石化公司石油一厂30×104t/a酮苯脱蜡装置施工蓝图。1.1.3我公司成功建设过石油一厂40万吨/年酮苯脱蜡装置安装工程及2005年石油二厂60万吨/年酮苯脱蜡脱油装置的施工工艺及经验。1.1.4抚顺石化分公司石油三厂50万吨/年重油催化装置拆迁施工经验。1.1.5《钢制管壳式换热器》GB151-991.1.6《钢制压力容器》GB150-981.2工程概况本装置共有换热器70台,形式为管板式、浮头式和U形管式换热器三种,换热器全部需要抽芯检查,部分管束需要更换新的管束。1.3换热器明细表中国石油抚顺石化公司原油集中加工、炼油结构调整技术改造工程30万吨/年酮苯脱蜡装置换热器抽芯试压方案第2页共9页表1设备明细序号设备位号设备名称设备规格数量试验压力(MPa)备注壳程(设计/试验)管程(设计/试验)1E-104预稀释溶剂加热器BIU400-6.4/6.4-30-6/25-2I16.4/7.856.4/7.852E-105/1~2一次溶剂(一段蜡下油液)-二次冷洗溶剂换热器BIU700-4.0/4.0-120-6/25-2I13.92/4.93.92/4.93E-108一段蜡下油液-脱油稀释冷洗溶剂换热器BIU700-2.5/2.5-120-6/25-4I12.5/3.1252.5/3.1254E-109/1~2脱油稀释冷洗溶剂氨冷器BIS1000-2.5/2.5-270-6/25-4I22.5/3.1252.5/3.1255E-110滤液-滤液一次塔顶二次换热器BIS900-1.6-210-6/25-6I11.6/2.01.6/2.0整体更换6E-111/1~2滤液-滤液一次塔顶一次换热器BIS500-1.6-55-6/25-4I21.57/2.121.57/2.127E-112/1~2滤液-脱蜡油二次换热器BES500-1.6-55-6/25-4I21.57/2.121.57/2.128E-113/1~2滤液-滤液二、三次塔顶二次换热器BES900-1.6-210-6/25-421.57/2.121.57/2.129E-114/1~2滤液-滤液二次塔顶换热器BJS1300-1.6-470-6/25-421.57/2.121.57/2.1210E-115/1~2滤液二次塔进料-脱蜡油换热器BES500-1.6-55-6/25-421.57/2.121.57/2.1211E-116/1~2滤液二次塔进料-滤液三次塔顶换热器BJS1400-1.6-545-6/25-421.57/2.121.57/2.1212E-117/1~2滤液三次塔进料预热器BJS600-2.5-90-6/25-222.45/3.062.45/3.0613E-118/1~3滤液三次塔进料加热器BIU1000-2.5-275-6/25-232.5/3.1252.5/3.12514E-118/4滤液三次塔进料加热器BIU1000-2.5-275-6/25-212.5/3.1252.5/3.125管束更换中国石油抚顺石化公司原油集中加工、炼油结构调整技术改造工程30万吨/年酮苯脱蜡装置换热器抽芯试压方案第3页共9页15E-119滤液四次塔进料加热器BIU600-2.5/2.5-140-6/19-212.45/3.062.45/3.0616E-120蜡液-蜡液一次塔顶二次换热器BJS900-1.6-200-6/25-4I11.57/2.121.57/2.1217E-121/1蜡液-蜡液一次塔顶一次换热器BJS1100-2.5-335-6/25-211.57/2.121.57/2.1218E-121/2蜡液-蜡液一次塔顶一次换热器BJS1100-2.5-335-6/25-211.57/2.121.57/2.12管束更换19E-122蜡液-蜡液、滤液、蜡下油液四次塔顶换热器BJS900-1.6-210-6/25-411.6/2.01.6/2.020E-123/1~2蜡液-蜡液二、三次塔顶二次换热器BJS-1000-1.6-270-6/25-4I21.6/2.01.6/2.021E-124/1蜡液-蜡液二次塔顶二次换热器BJS1300-1.6-470-6/25-411.6/2.01.6/2.0管束更换22E-124/2蜡液-蜡液二次塔顶二次换热器BJS1300-1.6-470-6/25-411.6/2.01.6/2.023E-125/1~2蜡液二次塔进料-蜡换热器BJS600-1.6-90-6/25-2I21.57/2.121.57/2.1224E-126/1蜡液一次塔进料-蜡液三次换热器BJS1500-1.6-640-6/25-411.57/2.121.57/2.12管束更换25E-126/2蜡液一次塔进料-蜡液三次换热器BJS1500-1.6-640-6/25-411.57/2.121.57/2.1226E-127蜡液三次塔进料预热器BJS600-2.5-90-6/25-412.45/3.062.45/3.0627E-128/1~3蜡液三次塔进料加热器BIU1100-2.5-335-6/25-232.5/3.1252.5/3.12528E-128/4蜡液三次塔进料加热器BIU1100-2.5-335-6/25-212.5/3.1252.5/3.125管束更换29E-129蜡液四次塔进料加热器BJS700-2.5-125-6/25-212.5/3.1252.5/3.12530E-130蜡下油液-滤液、蜡油、蜡下油液汽提塔顶换热器BJS800-1.6-160-6/25-412.5/3.1252.5/3.12531E-131/1~2蜡下油液-蜡下油液一次塔顶换热器BJS900-1.6-210-6/25-4I21.6/2.01.6/2.032E-132蜡下油液-蜡下油液二、三次塔顶二次换热器PDU900*6-2.5-21-2511.6/2.01.6/2.033E-133/1~2蜡下油液-蜡下油液二次塔顶换热器BJS1000-1.6-270-6/25-4I21.6/2.01.6/2.0中国石油抚顺石化公司原油集中加工、炼油结构调整技术改造工程30万吨/年酮苯脱蜡装置换热器抽芯试压方案第4页共9页34E-134/1~2蜡下油二次塔进料-蜡下油液换热器AES400-1.6-35-6/25-2I21.6/2.01.6/2.035E-135/1~2蜡下油液二次塔进料-蜡下油液三次塔顶换热器BJS1000-1.6-270-6/25-4I21.6/2.01.6/2.036E-136蜡下油液三次塔进料预热器BJS500-2.5-55-6/25-212.45/3.062.45/3.0637E-137/1~2蜡下油液三次塔进料加热器BJS1100-2.5-335-6/25-222.5/3.1252.5/3.12538E-138蜡下油液四次塔进料加热器BJS500-2.5-55-6/25-212.45/3.062.45/3.0639E-139酮塔进料换热器BJS500-1.6-55-6/25-4I11.6/2.01.6/2.040E-140热化套管加热器BIU600-6.4/6.4-85-6/25-4I16.4/7.856.4/7.8541E-141/1~2脱蜡氮气氨冷器BIU600-2.5-90-6/25-2I22.5/3.1252.5/3.12542E-142脱油氮气氨冷器BIU600-2.5-90-6/25-2I12.5/3.1252.5/3.12543E-143二段蜡下油加热器BES500-2.5-55-6/25-2I12.45/3.062.45/3.0644E-144溶剂氨冷器BIU1000-4.0/2.5-275-6/25-4I12.5/3.1253.92/4.945E-145溶剂氨冷器BIU1000-4.0/2.5-275-6/25-4I12.5/3.1253.92/4.946EW-102脱蜡氮气水冷器BES700-1.6-125-6/25-2I11.57/2.121.57/2.12管束更换47EW-103脱蜡氮气水冷器BES1000-1.6-280-6/25-2I11.6/2.01.6/2.0管束更换48EW-110脱蜡油水冷器BES500-1.6-55-6/25-4I11.6/2.121.6/2.12管束更换49EW-111蜡水冷器BES500-1.6-55-6/25-4I11.6/2.01.6/2.0管束更换50EW-112蜡下油水冷器BES400-1.6-50-6/25-4I11.6/2.01.6/2.0管束更换中国石油抚顺石化公司原油集中加工、炼油结构调整技术改造工程30万吨/年酮苯脱蜡装置换热器抽芯试压方案第5页共9页2试压准备工作4.1收集原设备监检报告,查看设备状况;4.2新的换热器管束应有管束出厂合格证明书4.2试压工机具、盲板制作准备4.3换热器封头拆除3换热器抽芯换热器的抽芯工作是在换热器拆除以后将换热器在抽芯场地集中摆放,对于高温处的螺栓应该提前涂抹松动剂,防止在松卸困难甚至卡死,将换热器管箱拆卸下以后,便可以进行抽芯工作。拆管箱和抽芯过程中,应对管箱标好设备位号,相应设备螺栓拆除后用编织带收集并挂牌标识设备位号,以免设备配件相互混淆,给设备恢复带来困难。另外应保存并记录
本文标题:换热器试压方案全
链接地址:https://www.777doc.com/doc-2451338 .html