您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 工程监理 > 2.10修改临电施工方案
北极阁三条32号翻改建工程【临电施工方案】第第00页页共共1111页页0目录1.编制依据....................................................................................................................................................12.工程概况.......................................................................................................................................................13.初步设计....................................................................................................................................................14.负荷计算....................................................................................................................................................25.变压器容量的选择.................................................................................................................................56.电流计算....................................................................................................................................................57.导线截面的选择和线路的整体布置................................................................................................68.临电平面布置及系统图........................................................................................................................69.各项保证措施...........................................................................................................................................7北极阁三条32号翻改建工程【临电施工方案】第第11页页共共1111页页1概要:本方案主要涉及北极阁三条32号翻改建工程施工现场临时生活、生产用电方案。1.编制依据1.1主要图集、标准、法规、规程、规范类别名称编号图集地方建筑电气通用图集92DQ1、4标准行业建筑电气安装施工工艺标准规范规程国家施工现场临时用电技术规范JGJ46-2005行业电气装置安装工程施工及验收规范GB50254-96建设工程施工现场供电安全规范GB50194-93地方北京市建筑工程施工安全操作规程DBJ01-62-20021.2土建编制的北极阁三条32#翻改建工程现场临建平面图1.3《环境与职业健康安全手册》2.工程概况北极阁三条32号翻改建工程,位于北京市东单北大街北侧。南邻北极阁三条,为公寓式酒店,建筑面积8534m2。地下1层,地上5层。结构形式为钢筋砼框架-剪力墙结构,建筑总高为18.2m。3.初步设计3.1本工程所在地为拆除翻建,现场临时用主变压器由甲方提供1台500KVA变压器。3.2本设计方案只考虑总箱及以下的线路及电器开关的选择。3.3根据《施工现场临时用电安全技术规范》JGJ46-2005规定,本供电系统采用TN-S系统(三相五线制)供电,即工作零线N和专用保护线PE在供电电源处严格分开。3.4在用电较集中处设二级箱,三级箱根据设备位置进行布置,其电源直接由附近二级箱引接。配电电缆采用铜芯聚氯乙烯绝缘聚氯乙烯护套铠装电力电缆供电。北极阁三条32号翻改建工程【临电施工方案】第第22页页共共1111页页23.5根据施工现场临时用电安全规范,施工现场用电设备实行三级配电三级漏电保护。4.负荷计算4.1主要机械设备序号设备名称单机功率(KW)数量合计(KW)备注一混凝土工程系统1砼地泵75175二电焊机及焊接设备95Jc=50%换算到Jc=100%1BX-500电弧对焊机19(kVA)357(kVA)2电渣压力焊机38138(kVA)三钢筋加工系统15.51弯曲机2122切断机3.513.53直螺纹套丝机5210四木工机械11.41电锯4142平刨2.212.23压刨4144砂轮机1.122.2五蛙式打夯机2.224.4六砂轮切割机2.224.4七振捣棒组1.133.3八施工电梯44144九空气压缩机7.517.5十消防泵30130十一塔吊45145十二小型电动工具总计10十三砂浆机37137十四办公室及照明20北极阁三条32号翻改建工程【临电施工方案】第第33页页共共1111页页34.2负荷计算4.2.1塔式起重机组查表KX=0.3cosφ=0.7tgφ=1.02Jc=0.4P1=2×√Jc×KX×P=2×√0.4×0.3×45=17KWQ1=P1×tgφ=17×1.02=17.5KVar4.2.2蛙式打夯机查表KX=0.4cosφ=0.7tgφ=1.02P2=KX×P=0.4×4.4=1.76KWQ2=P2×tgφ=1.76×1.02=1.79KVar4.2.3砼输送泵查表KX=0.6cosφ=0.7tgφ=1.02P3=KX×P=0.6×75=45KWQ3=P3×tgφ=45×1.02=46KVar4.2.4振捣器查表KX=0.65cosφ=0.7tgφ=1.02P4=KX×P=0.65×3.3=2.1KWQ4=P4×tgφ=2.1×1.02=2.2KVar4.2.5外用施工电梯查表KX=0.35cosφ=0.6tgφ=1.33Jc=0.4P5=2×√Jc×KX×P=2×√0.4×0.35×44=19KWQ5=P5×tgφ=19×1.33=26KVar4.2.6钢筋加工机械组查表KX=0.6cosφ=0.7tgφ=1.02P6=KX×P=0.6×15.5=9.3KWQ6=P6×tgφ=9.3×1.02=9.5KVar北极阁三条32号翻改建工程【临电施工方案】第第44页页共共1111页页44.2.7电焊机组查表KX=0.4cosφ=0.45tgφ=1.98Jc=0.65P7=√3×√Jc×KX×cosφ×95=24KWQ7=P7×tgφ=24×1.98=48KVar4.2.8空气压缩机查表KX=0.6cosφ=0.75tgφ=0.88P8=KX×P=0.6×7.5=4.5KWQ8=P8×tgφ=4.5×0.88=4KVar4.2.9消防泵查表KX=0.25cosφ=0.8tgφ=0.75P9=KX×P=0.25×30=7.5KWQ9=P9×tgφ=7.5×0.75=5.65KVar4.2.10其他电动工具查表KX=0.6cosφ=0.75tgφ=0.88P10=KX×P=0.6×10=6KWQ10=P10×tgφ=6×0.88=5.28KVar4.2.11木工加工机械组查表KX=0.4cosφ=0.75tgφ=0.88P11=KX×P=0.4×11.4=4.56KWQ11=P11×tgφ=4.56×0.88=4KVar4.2.12照明查表KX=0.8cosφ=0.95tgφ=0.33P13=KX×P=0.8×20=16KWQ13=P13×tgφ=16×0.33=5.28KVar4.2.13总的负荷计算线路相同系数取KX=0.85北极阁三条32号翻改建工程【临电施工方案】第第55页页共共1111页页5P总=KX×(P1+P2+……+P15)=0.85×156.72≈133KWQ总=KX(Q1+Q2+……+Q15)=0.85×175.2≈149KVarS总=√p总2+Q总2≈200KVA5.变压器容量的选择总计算容量为200KVA,现场市政变压器甲方提供引入。6.电流计算6.1总电流计算I总=S总/(√3×Ue)≈304A查表(部颁规定表4-2-9):电缆选用YJV223×120+2×70mm2即可6.2至塔吊导线电流电流计算至塔吊导线电流计算KX=1;COSθ=0.7Ijs=KxPe/(3ueCOSθ)=1×45/(3×0.38×0.7)=98A6.3至钢筋加工场导线电流计算至钢筋加工场导线电流计算Kx=1;COSθ=0.7Ijs=KxPe/(3ueCOSθ)=1×15.5/(3×0.38×0.7)=34A6.4至木工机械组导线电流计算至木工机械组导线电流计算KX=0.7;COSθ=0.88北极阁三条32号翻改建工程【临电施工方案】第第66页页共共1111页页6Ijs=KxPe/(3ueCOSθ)=1×11.4/(3×0.38×0.88)=20A导线截面选择结合本工地的临电线路计算,根据电力电缆直埋地敷设的载流量表,选用如下导线型号及截面:一级箱至塔吊处二级箱:YJV223×25+2×16mm2一级箱至钢筋场处二级箱:YJV225×10mm2一级箱至木工房处二级箱:YJV225×6mm2(详见现场临电布置图)经验算,线路电压降均未超过标准要求。7.导线截面的选择和线路的整体布置根据目前外线及变压器的常规提供情况,本工程采用具有专用保护零线的TN-S接零保护系统,即三线五线制,并且在总配电柜、各二级箱处、大型用电设备(塔吊、室外电梯)处分别设置重复接地。按照“配电柜→二级配电箱→三级箱(插座箱)→手提配电箱”分级配电、每一级均有漏电保护的形式,配电柜置于临电配电间内,电源由变压器用电缆直接引入;配电线路采用放射式多路主干线送至各用电相对集中区域,然后在每个供电区域内再采用放射和树干式相结合的配电方式。根据施工现场平面布置及用电负荷分布情况,由二级箱深入负荷相对集中区域,插座箱分散供电,施工作业面采用手提箱供细部施工及照明。消防泵房专用配电箱由总配电柜上口引入,以保证供电的可靠性。由于电缆的供电半径不超过700米,电压降不会小于5%,故可以不考虑“按导线允许电压降选择”这一条。所以本工程电缆线路的选择仅按“导线允许长时间通过最大正常工作电流”进行电缆型号的选择,考虑到施工现场条件差、临时性强、变化大等因素,电缆选用YJV型号。8.临电平面布置及系统图临电平面布置及系统详见附图。北极阁三条32号翻改建工程【临电施工方案】第第77页页共共1111页页79.各项保证措施9.1安全用电管理9.1.1建立、健全用电管理机构,组织好运行、维护专业班组,明确管理机构与专业班组的职责。9.1.2建立、健全用电设施的运行及维护操作规定;运行及维护人员必须学习操作规定,熟悉本工程的临电系统。9.1.3建立技术交底制度。向专业电工、各类用电人员介绍临时用电施工组织设计和安全用电技术措施的总体意图、技术内容和注意事项,并应在技术交底文字资料上履行交底人和接受人的签字手续,注明交底日期。9.1.4建立安全检测制度。建立安全检测制度。从临时用电工程竣工开始,定期对临时用电工程进行检测,主要内容是:接地电阻值,电气设备绝缘电阻值,漏电保护器动作参数等,以监视临时用电工程是否安全可靠,并作好检测记录。9.1.5
本文标题:2.10修改临电施工方案
链接地址:https://www.777doc.com/doc-3103567 .html