您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 工程监理 > 临时用电专项施工方案-2011-4-8-
1目录一、编制依据····································2页二、工程概况···································2页三、设计内容和步骤·······························4页四、用电管理·····································10页五、电工·········································11页六、安全距离与外电防护···························11页七、供电路线·····································12页八、电缆线路·····································12页九、配电柜(盘)、配电箱及开关箱·················13页十、电器装置的选择·······························14页十一、使用与维护·································15页十二、照明·······································15页十三、接地·······································16页十四、防雷·······································19页十五、临时用电施工及使用要求·····················19页十六、附图:····································21页2临时用电专项方案一、编制依据1、《施工现场临时用电安全技术规范JGJ46-2005》2、《建设工程施工现场供用电安全规程GB50194-2005》3、《工程建设标准强制性条文》4、《低压配电设计规范》GB50054-95中国建筑工业出版社5、《通用用电设备配电设计规范》GB50055-93中国建筑工业出版社6、《供配电系统设计规范》GB50052-95中国建筑工业出版社7、《建筑施工安全检查标准》JGJ59-998、《基坑平面布置图》二、工程概况1、由杭州ΧΧΧΧ有限公司开发建设的ΧΧ国际广场位于杭州市滨江区。本工程东南侧及西北侧分别布置了一栋230.9米高的塔楼,两栋超高层主体之间由一栋100米高的酒店(场地东北侧)和4层裙房相连、整个场地统设三层地下室,主要功能为车库、人防及设备用房,地下室的长度达126.7米,宽度达105.8米。工程桩采用大直径钻孔灌注桩。地下室顶板标高-2.10、地下一层标高-6.70、地下二层标高-10.40、地下三层标高-14.90。2、本工程建筑用地面积为15161平方米;总建筑面积203785.75平方米(其中地下三层建筑面积43079.75平方米;地上一~六十五层建筑面积160706.60平方米);建筑基底面积为5274.5平方米。本项目A、B型二栋超高层楼,地上共65层,总高度为230.90米,各层层高为5000、4500×3、5100、3400×10、4500、3400×13、4500、3400×35层;C型一栋高层楼地上为26层,总高度为99.2米,各层层高为5000、4500×3、5100、3600×21层;裙房楼地上为四层,总高度为18.5米,各层层高为5000、4500×3层、本大厦由酒店、办公、住宅及含商业和酒店配套服务的裙房多项功能为一体组成。。3、本工程基础设计等级甲级,建筑结构安全等级为二级,建筑耐火等级一级,地下室防水等级二级,混凝土结构抗震等级:地下室一~二层抗震等级为二级,地下室三层抗震等级为三级,地上各栋混凝土结构抗震等级为一~三级;地下人防按甲类核5级、常5级,防化等级乙级。4、工程施工场地已完成平整,甲方提供施工单位用水、用电的接驳点各一个,均设于现场边缘。并要求通往施工范围的道路可通行各种施工车辆,供施工设备及材料进场。3平面位置详见【施工现场总平面布置图】【基坑围护工程施工现场布置图】。(见附图)质量目标:确保“钱江杯”争创“鲁班奖”安全目标:确保省级文明标化工地。施工现场“三通一平”已能满足施工需要,甲方提供400KVA三只变压器作为1#2#配电房施工用电,电压为400V。5、施工现场用电量统计表如下(所有设备用电功率为KW)拟投入的主要施工机械设备表序号机械名称、型号规格(功率)进场数量(台)备注1水泥搅拌桩机ZKD65-3400KW1套步腹式搅拌桩2500L灰浆搅拌机4KW1步腹式搅拌桩39M3空压机VF-12/745KW1步腹式搅拌桩4高压旋喷桩机GY-120150KW1台高压旋喷桩(用电交叉)5围护灌注桩机GPS-15-1865KW8台钻孔灌注桩6工程灌注桩机GPS-15-1865KW8台钻孔灌注桩7水泥罐及输送设备50T2搅拌桩钻孔灌注桩8PC120挖土机2搅拌桩道沟、挖土9PC200挖土机2~6挖土100.4M3小挖土机1挖土1120T自卸汽车20挖土12高压水泵7.5KW2施工供水13泥浆泵7.5KW2基坑排水14泥浆泵22KW3桩机泥浆循环15深井潜水泵1.5KW40基坑排水16BX-300电焊机17KW3格构式钢柱、钢筋焊接17人力翻斗车20挖土18自备柴油发电机200KW1用于工程应急19自备柴油发电机57KW1用于办公室应急20空压机+风镐7.5KW15套凿支撑、凿桩21对焊机UNL-1001台压顶、支撑22调直机GJ85/41台压顶、支撑423切断机DA40-13台压顶、支撑24弯曲机WJ2241台压顶、支撑25切割机D42-12台压顶、支撑26木工圆盘机HB50-6B2台压顶、支撑27砂浆搅拌机HJ2242台压顶、支撑28插入式振动器HZ6-5010台压顶、支撑砼浇捣29平板式振动器2台压顶、支撑砼浇捣30商品砼输送泵HJ-TSB1台商品砼提供31塔吊(QTZ250)ZJ703055KW1台自备32塔吊QTZ6012—40.7KW1台自备三、设计内容和步骤1、现场勘察及初步设计1)施工现场范围内上、下水管道及各种埋地线路径已清除,施工现场已通水电,现场内无一、二级负荷。施工现场由供电部门设一供电总箱内有计量设备。本设计只负责总箱以下的线路、电气开关的选择。2)根据施工现场用电设备布置情况,在场内沿围墙架设电缆,LFG至分配电箱,再由分配电箱引至各用电设备的开关箱。3)根据《施工现场临时用电安全技术规范》JGJ46-2005规定,本供电系统采用TN-S(三相五线制)供电,设置二个回路。2、确定计算负荷(第一回路)1)钢筋机械组Kx=0.7tgψ=1.08cosψ=0.68Pe1=3×2+2×3+2×3+2×7.5=33kwPjs1=Kx×Pe1=0.7×33=23.10kw,Qjs1=Pjs1×tg=23.10×1.08=24.95Kwar2)井架组Kx=0.7tgψ=1.02cosψ=0.7Pe2=7.5×6=45kwPjs2=Kx×Pe2=0.7×45=31.5kw,Qjs1=Pjs2×tgψ=31.5×1.02=32.13Kwar3)塔吊组Kx=0.7tgψ=1.02cosψ=0.7Pe3=55.5kwPjs1=Kx×Pe3=0.7×55.5=38.85kw,Qjs3=Pjs3×tgψ=38.85×1.02=39.63Kwar54)电焊组Kx=0.45tgψ=1.98cosψ=0.45○1将Jc=50%统一换算到Jc=100%时额定容量Pe4=√Jc/Jc100×Pn=√0.5×13=9.19kw○2计算负荷Pjs5=Kx×Pe5=0.45×9.19=4.14kw,Qjs5=Pjs5×tgψ=4.14×1.98=8.20Kwar5)锯木组Kx=0.7tgψ=0.88cosψ=0.75Pe5=3×8=24kwPjs5=Kx×Pe5=0.7×24=16.8kw,Qjs5=Pjs5×tgψ=16.8×0.88=14.78Kwar6)砂浆机组Kx=0.7tgψ=1.08cosψ=0.68Pe6=3×6=18kwPjs6=Kx×Pe6=0.7×18=12.6kw,Qjs6=Pjs6×tgψ=12.6×1.08=13.61Kwar7)振动棒组Kx=0.7tgψ=1.02cosψ=0.7Pe6=1.1×12=13.2kwPjs6=Kx×Pe6=0.7×13.2=9.24kw,Qjs6=Pjs6×tgψ=9.24×1.02=9.42Kwar6)总的计算负荷计算、干线同期系数取Kx=0.9总的有用功率Pjs=Kx×(Pjs1+Pjs2+``````+Pjsn)=0.9×(23.10+31.5+38.85+4.14+16.8+12.6+9.24)=122.6kw总的无用功率Qjs=Kx×(Qjs1+Qjs2+``````+Qjsn)=0.9×(24.95+32.13+39.63+8.2+14.78+13.61+9.42)=128.5Kwar总的视在功率Sjs=√Pjs2+Qjs2=√122.62+128.52=177.6KWA总的计算电流Jjs=Sjs/√3Ve=269A选用90mm2铜芯塑料线,其允许持续电流270A269A3、确定计算负荷(第二回路)1)井架组Kx=0.7tgψ=1.02cosψ=0.7Pe1=7.5×6=45kwPjs1=Kx×Pe2=0.7×45=31.5kw,Qjs1=Pjs2×tgψ=31.5×1.02=32.13Kwar2)电焊组Kx=0.45tgψ=1.98cosψ=0.45○1将Jc=50%统一换算到Jc=100%时额定容量6Pe2=√Jc/Jc100×Pn=√0.5×35=24.75kw○2计算负荷Pjs3=Kx×Pe3=0.45×24.75=11.14kw,Qjs2=Pjs3×tgψ=11.14×1.98=22.06Kwar3)锯木组Kx=0.7tgψ=0.88cosψ=0.75Pe4=3×7=21kwPjs4=Kx×Pe4=0.7×21=14.7kw,Qjs4=Pjs4×tgψ=14.7×0.88=12.94Kwar4)砂浆机组Kx=0.7tgψ=1.08cosψ=0.68Pe5=3×6=18kwPjs5=Kx×Pe5=0.7×18=12.6kw,Qjs5=Pjs5×tgψ=12.6×1.08=13.61Kwar5)振动棒组Kx=0.7tgψ=1.02cosψ=0.7Pe6=1.1×6=6.6kwPjs6=Kx×Pe6=0.7×6.6=4.62kw,Qjs6=Pjs6×tgψ=4.62×1.02=4.71Kwar6)总的计算负荷计算、干线同期系数取Kx=0.9总的有用功率Pjs=Kx×(Pjs1+Pjs2+``````+Pjsn)=0.9×(31.5+24.75+14.7+12.6+4.62)=88.17kw总的无用功率Qjs=Kx×(Qjs1+Qjs2+``````+Qjsn)=0.9×(32.13+22.06+12.94+13.61+4.71)=85.45Kwar总的视在功率Sjs=√Pjs2+Qjs2=√288.172+85.452=122.78KWA总的计算电流Jjs=Sjs/√3Ve=122.78/√3×0.35=201A选用70mm2铜芯塑料线,其允许持续电流210A201A。另外生活用电单独设一个回路,选用25mm2铜芯塑料线,宿舍区供电采用36V电压供电。打桩施工阶段用电目前业主单位提供三台400KW变压器,分别配置1#2#3#三台一级配电柜(工程现场西南角的1#配电房已经配置了二台400KW变压器和1#2#二只一级配电柜,西北角的2#配电房已经配置了一台400KW变压器和3#一只一级配电柜,供本工程使用)。通过各施工片用电总量的计算来验算变压器的供应能力。P总=1.05×(K1∑P1C0SΦ+K2∑P2)×1.10式中:P总——设备总用量需要量K1——电动机同时需要系数∑P1——各种电力设备总功率7C0SΦ——电动平均功率因素,取C0SΦ=0.75K2——电焊机同时需要系数∑P2
本文标题:临时用电专项施工方案-2011-4-8-
链接地址:https://www.777doc.com/doc-3512948 .html