您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > 2804001-0220-00 220kV智能变电站计算机监控系统通用技术规范(范本)
220kV智能变电站监控系统通用技术规范(范本)317318国家电网公司物资采购标准(2009年版·第三批)智能设备卷(三)智能变电站状态监测册本规范对应的专用技术规范目录序号名称编号1220kV智能变电站监控系统专用技术规范(范本)2804001022001220kV智能变电站监控系统通用技术规范(范本)319220kV智能变电站监控系统技术规范(范本)使用说明1.本技术规范分为通用部分、专用部分。2.项目单位根据需求选择所需设备的技术规范,技术规范通用部分条款及专用部分固化的参数原则上不能更改。3.项目单位应按实际要求填写“项目需求部分”。对于项目的一次、二次及土建的接口要求可在专用技术规范中提出。如确实需要改动以下部分,项目单位应填写专用技术规范“项目单位技术差异表”并加盖该网、省公司物资部(招投标管理中心)公章,与辅助说明文件随招标计划一起提交至招标文件审查会:1)改动通用技术规范及专用技术规范固化的参数;2)项目单位要求值超出标准技术参数值;3)需要修正污秽、温度、海拔、覆冰厚度、耐地震能力等条件。经标书审查会同意后,对专用技术规范的修改形成“项目单位技术差异表”,放入专用技术规范中,随招标文件同时发出并视为有效,否则将视为无差异。4.投标人逐项响应专用技术规范中“1标准技术参数”、“2项目单位需求部分”和“3投标人响应部分”三部分相应内容。填写投标人响应部分,应严格按招标文件专用技术规范的“招标人要求值”一栏填写相应的招标文件投标人响应部分的表格。投标人填写技术参数和性能要求响应表时,如有偏差,除填写“投标人技术偏差表”外,必要时应提供相应试验报告。5.本技术规范的页面、标题等均为统一格式,不得随意更改。6.对于保护测控一体化装置,其保护部分的技术要求参见相关保护装置的技术规范。320国家电网公司物资采购标准(2009年版·第三批)智能设备卷(三)智能变电站状态监测册目次220kV智能变电站监控系统技术规范(范本)使用说明·························································3191总则·······················································································································3211.1引言···················································································································3211.2供方职责··············································································································3212技术规范要求···········································································································3212.1使用环境条件·········································································································3212.2工作条件··············································································································3222.3标准和规范············································································································3242.4技术性能要求·········································································································3272.5系统集成··············································································································3412.6屏体及其他要求·······································································································3413试验·······················································································································3423.1工厂试验··············································································································3423.2现场验收试验·········································································································3434技术服务、设计联络、工厂检验和监造··········································································3444.1技术服务··············································································································3444.2设计联络··············································································································3464.3工厂验收··············································································································347附录A计算机监控系统监控范围····················································································348A.1模拟量················································································································348A.2状态量················································································································349A.3控制量················································································································350220kV智能变电站监控系统通用技术规范(范本)3211总则1.1引言投标人应具有ISO9001质量保证体系认证证书,宜具有ISO14001环境管理体系认证证书,宜具有OHSAS18001职业健康安全管理体系认证证书,并具有AAA级资信等级证书,宜具有重合同守信用企业证书并具备良好的财务状况和商业信誉。必须具备国家电网公司检验检测机构检验合格证书。提供的计算机监控系统装置应在国家或电力工业检验检测机构通过DL/T860、动模试验、电磁兼容及型式试验。提供的交换机设备必须是工业级的,且应在国家或电力工业检验检测机构通过电磁兼容及型式试验并具有国家电网公司交换机入网检测A类产品资质。投标人应满足《国家电网公司十八项电网重大反事故措施(试行)》以及《国家电网公司输变电工程通用设备(2009年版)》,满足变电所无人值班的要求。招标方在专用技术规范提出的要求投标人也应满足。提供的产品应有省级鉴定文件或等同有效的证明文件。中标单位应按买方要求开展相关检验测试。(注:第一批招标项目可暂不提供鉴定文件,相关检验测试报告在供货前提供。)1.1.1本技术规范提出了对基于DL/T860(IEC61850)标准的220kV智能变电站计算机监控系统的系统结构、技术参数、功能、试验等方面的技术要求。1.1.2本技术规范提出的是最低限度的要求,并未对一切技术细节作出规定,也未充分引述有关标准和规范的条文,供方应提供符合本技术规范和工业标准的优质产品。1.1.3如果投标人没有以书面形式对本技术规范的条文提出差异,则意味着投标人提供的设备完全符合本技术规范的要求。如有与本技术规范要求不一致的地方,必须逐项在“投标人技术偏差表”中列出。如果没有不一致的地方,必须在“投标人技术偏差表”中写明为“无偏差”。1.1.4本技术规范所使用的标准如遇与投标人所执行的标准不一致时按较高的标准执行。1.1.5本技术规范将作为订货合同的附件,与合同具有同等的法律效力。本技术规范未尽事宜,由合同签约双方在合同谈判时协商确定。1.1.6本技术规范中涉及有关商务方面的内容,如与招标文件的商务部分有矛盾时,以商务部分为准。1.1.7本通用技术规范各条款如与专用技术规范有冲突,以专用技术规范为准。1.2供方职责供方的工作范围将包括但不限于下列内容。1.2.1提供标书内所有设备及设计说明书及制造方面的说明。1.2.2提供国家或电力工业检验检测机构出具的型式试验报告,以便确认供货设备能否满足所有的性能要求。1.2.3提供设备安装、使用的说明书。1.2.4提供试验和检验的标准,包括试验报告和试验数据。1.2.5提供图纸、制造和质量保证过程的一览表以及标书规定的其他资料。1.2.6提供设备管理和运行所需有关资料。1.2.7所提供设备应发运到规定的目的地。1.2.8如标准、规范与本技术规范的条文有明显的冲突,则供方应在制造设备前用书面形式将冲突和解决办法告知需方,并经需方确认后,才能进行设备制造。1.2.9现场服务。2技术规范要求2.1使用环境条件2.1.1海拔:≤3000m。322国家电网公司物资采购标准(2009年版·第三批)智能设备卷(三)智能变电站状态监测册2.1.2环境温度(室内):最高气温:45℃。最低气温:-5℃。最大日温差:25℃。2.1.3最大相对湿度:日平均:95%。月平均:90%。2.1.4工作温度:间隔层设备:-25℃~55℃。站控层设备:-5℃~45℃。交换机设备(户内):-5℃~45℃。交换机设备(户外):-25℃~55℃。2.1.5抗地震能力水平加速度0.3g,垂直加速度0.15g,同时作用。2.1.6安装方式室内安装,为无专设屏蔽、无抗静电措施的房间,室内设有空调。开关场就地安装,为无屏蔽、无抗静电措施的室外空间。2.2工作条件2.2.1额定值2.2.1.1站控层工作电源额定值额定交流电压:220V。额定直流电压:220V/110V。UPS电压:
本文标题:2804001-0220-00 220kV智能变电站计算机监控系统通用技术规范(范本)
链接地址:https://www.777doc.com/doc-3633308 .html