序号节能施工单位名称项目细部能源别投资金额:元节约率:%改善前费用:元年节减金额:元T8-T5照明灯电52,70143%69,08629,707智能模糊控制电357,14215%1,705,107255,766冷凝器加装清晰装置电218,70010%809,01080,901制冷剂电264,3208%1,203,73896,299玻璃贴膜电680,00014%1,566,964219,375用热泵取代燃油锅炉油446,52572%396,821285,711炉灶用防空少节能器LPG171,86415%1,188,000178,200加装节水花洒水90,45030%244,00073,2002,281,70217%7,182,7251,219,159智能模糊控制、泵变频电807,00010%681,22068,122用热泵取代燃油锅炉油375,84081%439,157355,7171,182,84038%1,120,377423,839T8-T5照明灯电150,29144%352,998156,731冷凝器自动清洗装置电230,00015%564,97384,746380,29126%917,971241,477相控技术和红外感应监控电76,80043%79,61934,236TISH-MAN NIGR-60#纳米吸收隔热膜电400,000126,000采用水源热泵油375,840100%162,607162,607中央空调系统智能模糊自动控制油130,79010%795,07079,507983,43039%1,037,296402,350T8-T5照明灯电119,40051%181,17592,399采用水源热泵油500,000100%455,688455,688中央空调系统智能模糊自动控制电210,00030%402,510120,753829,40064%1,039,373668,840深圳节能协会(SESA)酒店类客户节能案例汇总深圳帝都酒店深圳富丽华酒店21深圳深华国宾大酒店深圳长城酒店博林诺富特酒店543项目中央空调系统照明系统手扶梯玻璃贴膜热水系统厨房燃油空调系统小计小计小计小计小计照明系统热水系统中央空调热水系统照明系统空调系统建筑节能热水系统灶具用水系统采用水源热泵电230,12064%193,014123,529炉灶用防空少节能器油77,00010%694,62069,462307,12022%887,634192,991采用水源热泵LNG273,76064%349,875223,920智能模糊控制、泵变频电420,00015%1,746,667262,000693,76023%2,096,542485,920T8-T5照明灯电174,26067%136,75791,354加装能量回馈器电82,70025%121,54430,386TISH-MAN NIGR-60#纳米吸收隔热膜电570,000100,800用热泵取代燃油锅炉油712,32042%1,178,861499,837加装节水花洒水150,34812%1,118,400134,208炉灶用防空烧节能器LPG82,50015%258,39338,7591,772,12832%2,813,956895,344加装系统节电器电1,782,0005%11,447,300572,365T8-T5照明灯电329,76059%347,727204,116中央空调变频技术电2,091,31715%7,337,9531,100,693冷凝器加装清洗装置电322,7607%1,329,70093,079加装末端风机无机调速电261,90025%650,752162,688加装有源能量回馈器电168,30037%224,63883,790玻璃贴膜(Sterling60)电216,9803%2,782,25886,250用热泵取代燃油锅炉油2,782,03249%3,923,8871,938,400加装节水花洒水1,192,48030%3,294,000988,2009,147,52917%31,338,2165,229,581T8-T5照明灯电298,96950%427,099213,549智能模糊控制电330,00030%647,059194,118玻璃贴膜(Sterling60)电240,000133,000133,000用热泵取代燃油锅炉油356,16057%390,526222,600加装节水装置水70,00030%106,06131,818厨房采用节能厨具LPG88,00030%162,96348,8891,383,12945%1,866,707843,974T8-T5照明灯电108,99248%98,75647,403智能模糊控制电25,00025%383,41695,854冷凝器加装清洗装置电69,57510%232,78023,278加装末端风机无极调速电57,12069%45,98031,726加装有源能量回馈器电29,88030%34,56010,368玻璃贴膜电300,00072,00035,000加装节水装置水40,80030%60,91318,274856,36728%928,405261,903小计小计11深圳新洲酒店照明系统中央空调系统电梯系统建筑节能用水系统深圳市庐山酒店玻璃贴膜热水系统用水系统燃气系统深圳彭年酒店深圳维也纳酒店8910小计小计小计空调系统小计建筑节能热水系统用水系统燃气系统电梯系统建筑节能中央空调系统热水系统供水系统照明系统热水系统空调系统照明系统电梯系统供电系统照明系统深圳景明达酒店7深圳景轩酒店6热水系统厨房燃油T8-T5照明灯电254,37742%332,303139,235冷凝器加装清洗装置电448,8005%2,590,440129,522加装末端风机无极调速电231,00010%587,02058,702更换环保制冷剂电638,0005%2,590,440129,522加装有源能量回馈器电209,10027%281,03474,755玻璃贴膜电646,1846%3,682,900220,974用热泵取代燃油锅炉电845,26249%1,655,101817,620加装节水花洒水256,36030%454,680136,404厨房采用节能灶具LPG27,50023%41,7139,5943,556,58314%12,215,6311,716,328T8-T5照明灯电116,02853%238,487125,921中央空调系统智能模糊自动控制电47,5207%545,90038,213冷凝器加装清洗装置电226,51210%789,42078,942加装末端风机无极调速电133,34410%716,39071,639加装有源能量回馈器电58,80025%90,24022,560热泵代替原锅炉供热LPG326,48043%502,663217,653加装节水花洒水261,76830%480,000144,000加装高效蒸汽发生器LPG60,72025%79,00019,7501,231,17221%3,442,100718,678小计小计深圳粤海酒店深圳阳光酒店1312照明系统中央空调系统电梯系统热水系统供水系统燃气系统中央空调系统电梯系统建筑节能热水系统用水系统燃气系统照明系统T8-T5照明灯电169,29755%130,55872,068智能模糊控制电910,80017%2,746,902475,214冷凝器加装清洗装置电417,4508%1,752,713140,217加装末端风机无极调速电208,51630%179,66353,899加装有源能量回馈器电172,32033%373,644121,808玻璃贴膜(Sterling60)电1,867,800511,098用热泵取代燃油锅炉油356,16025%1,040,564260,141加装节水装置水142,80030%325,45797,637厨房采用节能灶具LPG209,00029%242,37770,7744,454,14327%6,791,8771,802,856智能模糊控制电256,4004%462,110184,844用热泵取代燃油锅炉油132,00083%102,33484,937388,40048%564,444269,781T8-T5照明灯电390,50038%599,754235,759增加200冷吨螺杆机(带热回收器)电1,600,00043%535,427229,443冷凝器加装清洗装置电360,00015%1,411,765211,1162,350,50027%2,546,946676,318加装系统节电器电927,9605%5,320,140266,007T8-T5照明灯电165,01549%144,69370,307泵的变频技术电1,390,18115%4,914,880737,232冷凝器加装清洗装置电235,0367%1,329,70093,079加装末端风机无极调速电209,61666%148,16298,083更换一台650RT主机电1,360,00025%2,441,555598,181加装有源能量回馈器电134,75012%677,15881,259用热泵取代燃油锅炉油1,560,43254%1,585,185856,000加装节水装置水194,40030%268,41780,5258,527,89018%19,377,1063,556,99140,326,38420%96,167,30519,606,330小计深航锦江国际酒店14深圳新都酒店17深圳名兰苑酒店15深圳五洲宾馆16燃气系统热水系统照明系统中央空调系统电梯系统用水系统供热系统小计小计照明系统中央空调系统电梯系统建筑节能热水系统用水系统合计中央空调系统空调系统供电系统小计照明系统序号节能施工单位名称项目项目细部能源别投资金额(元)节约率:%改善前费用:元年节减金额(元)照明系统T8→T5照明灯电631,68445%465,437208,981冷冻冷却泵组变频电154,00031%238,46473,924冷凝器自动清洗装置电220,00015%350,00052,5001,005,68432%1,053,901335,405配电系统使用Sentinel 160K节能器电753,2409%4,080,000367,200照明系统T8→T5照明灯电502,42537%1,022,495378,323R418A置换R22制冷剂电208,64015%253,28737,993变频设备电584,16015%1,198,053179,708电梯系统能量回馈器电118,00015%285,92742,889热水系统两台13kw智能热泵热水机组电430,00056%167,42593,758玻璃贴膜电406,3706%1,171,76770,306水系统加装节水花洒水78,60025%264,60066,1503,081,43515%8,443,5531,236,327照明系统T8→T5照明灯电373,61743%355,227152,037冷冻机组冷媒蒸气的利用柴油400,00024%628,561151,483冷凝器自动清洗装置电240,00010%802,40080,2401,013,61721%1,786,187383,760照明系统T8→T5照明灯电244,35432%425,76091,423空调系统置换制冷剂电563,59810%5,560,834378,136电梯系统加装能量回馈器电55,70030%73,31015,000配电系统加系统节电器电689,5008%6,059,904329,659热水系统空调废热利用电1,725,50031%2,547,939544,192建筑节能玻璃贴膜电459,00015%1,657,107169,025恒压供水加供水补压装置电162,00085%70,51868,000用水系统加装节水花洒水78
本文标题:深圳节能协会(SESA)酒店类客户节能案例汇总
链接地址:https://www.777doc.com/doc-368010 .html