您好,欢迎访问三七文档
当前位置:首页 > 办公文档 > 招标投标 > 贝朗血透机维修手册自检
1Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020SelfTestSW7.5xServiceManual-Chapter3维修手册第三章2Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020常规通常每次开机后进入治疗前都必须进行自检。所有关系到安全的功能都将被测试,确保治疗安全进行。治疗开始前不可跳过自检。仅在自检程序完全通过后开始治疗程序才是安全可靠的。3Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020安全第一-自检程序步骤1.开机后软件和定标数据检查上次消毒记录检查2.治疗前自检safetysystem安全报警系统internalhydraulic进水bloodleak漏血传感器Heater加热器Temperature温度传感器Conductivity电导度传感器Ultrafiltration超滤部分SAD空气传感器pressuresensors血路压力4.消毒冲洗消毒:温度、浓度达到要求+冲洗ok3.治疗同时传感器不间断的监测并由独立的监测系统处理器计算报警临界值自动或手动开机4Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020开机初始化开机信号发送到SMPSLLC初始化硬件装载程序装载定标数据LLS初始化硬件装载程序装载定标数据启动Diabus通讯检查检测板开关K1位置0-2-3启动与开关位置相应的程序Therapy-TSM-SoftwareUpdate报警信息:RAM/ROMError或CRCcalibrationError如果自检失败TLC主板BIOS程序启动从硬盘启动程序5Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020治疗之前•冲洗水路填充水箱,冲洗整个水路6Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020自检•所有测试步骤都由控制板控制完成•监测板通过自己的传感器监测整个过程。•监测板测试D24V和B24V电压继电器各3秒。•打开24V继电器,给控制板进行下一步测试提供电压。•任一自检步骤如失败将自动循环监测该步骤。•维修界面有自检程序代码,显示自检程序进度。7Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020自检–维修界面chapter3page36-38自检代码8Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020自检–自检代码总览CodeTestCode00xxxNotestsorrinsing16xxxSoundandLEDtest(fromSW7.51)17xxxLLCDFSTest18(analogvoltagetestfromSW7.51andsup.version3)11xxxBloodleakdetector12xxxDFSleakagetest15xxxHDFonline完整性测试(onlyforDialogHDFonline)20xxxUFpump21xxxConductivity22xxxTemperatureTSD30xxxSAD:leveltest31xxxSAD:countertest32xxxPressuresensorsbloodside:equalitytestforbloodsidepressuresensors33xxxPressuresensorsbloodside:bloodsidepressuretest34xxxSubstitutionpumpHDFbag(onlyforDialogHDFbag)35xxxFlowdetectorHDFbag(onlyforDialogHDFbag)36xxxLoadcellHDFbag(onlyforDialogHDFbag)37xxxDisinfectionvalveVD40xxxLeakagetestsubstitutionlineSonlineHDFonline9Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020自检状态chapter3page36子代码格式TTSSx:TTSSxLLCtestcodetoLLS测试步骤Performedteststep执行测试进度Numberofperformedrepeats循环测试次数0xrepeatsuntilerrormessage失败后即重复自检举例:10020DuringthefirsttestoftheheaterrelaytestLLSdidnotanswerin10swiththetestcode10.23050Bloodleakdetectorcompensation:2minnowaterbeforeteststart.33701SecondBSpressuretestterminated,becauseduringautopriming,e.g.anLFerroroccured.37991VDtestpassedafterthesecondtime.10Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.14/02/2020TTSSS:TTSSSLLStestcodetoLLCPerformedteststepLLCSubcodeThird(x=0,1,2)bloodleakdetectortest:Sendsignaltobloodleakdetectortask(Seetable,LLCcodecolumn.)LLSSubcodeBloodleakdetectortest:Measurementofredandgreenlevel(Seetable,LLScodecolumn.)CodeLLCLLSCode1.1102xPrerequisitesforTest:UplinetankmustbefilledTimeout2min2.Testcode=11toLLSTestcode=11backtoLLC3.1110xEV_TEST_BLOODLEAK_ONONBloodleakTaskIDTestinitialisation(VGDON)11000–4.Singlemeasurementofgreen,Singlemeasurementofred,thencomparisonof:redgreen+0.2Vnotimeout11003110045.Acknowledgewithswitch-offVGD11005–6.1120xWaitforD24OFF(timeout30s)110117.VGDON110128.1130xWaitforD24ON(timeout30s)9.1199xCompleted(TTSSx)(TTSSS)1110211004自检–显示状态11Authors:GuenterNissenHeikoRiemenschneiderTrainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyor
本文标题:贝朗血透机维修手册自检
链接地址:https://www.777doc.com/doc-3754768 .html