600MW汽轮发电机运行参数电气参数有功(出力)MWTRL铭牌工况MCR最大连续VWO阀门全开设计值600632.96603#试验值6006504#试验值600640电气参数功率因数COSΦ和无功MVar滞相0.9无功291MVar视在功率667MVA进相0.95无功-197MVar视在功率631MVA限制进相能力的主要因素:发电机端部发热(和氢压有关)厂用电压(6kV和380V的最低值)静稳定极限,最大功角70º(等值机90º)珠海3号600MW-70MVar限制因素380V下降珠海4号600MW-100MVar限制因素380V下降出力曲线(P-Q图)电压和频率偏差电压偏差±5%19kV~21kV频率偏差-3%~2%48.5Hz~51Hz电压和频率偏差对发电机和汽轮机的危害频率Hz允许时间每次(s)累计(min)51~51.5303048.5~4830030048~47.5606047.5~47201047~46.552电压和频率同时偏差国标7064的规定:电机应能在区域A内连续运行,并实现本标准所规定的基本功能,但其性能不必与额定电压和频率(见图1中的额定点)时的性能完全相符,可能呈现某些差异,温升可比额定电压和频率时高。电机应能在区域B内运行,并实现基本功能,但性能与额定电压和频率时的差异将大于在区域A内运行的电机,温升可较额定电压和频率时高,并很可能高于区域A。不推荐在区域B的边界上持续运行。定子电流额定值19245A允许短时过电流倍数(I2-1)t=37.5st-10~60秒不对称运行(负序)能力连续I2/IN≥10%短时(I2/IN)2t≥10s提高负序能力的措施(1)大齿三个阻尼槽(2)嵌线槽内的阻尼负序电流的计算对称分量法I(倍数)t(秒)1.5301.39401.32501.27601.160负序电流对转子的危害励磁电压和电流额定励磁电压407V额定励磁电流4145A负载励磁电流的确定(1)查V形曲线:按设计参数计算,必须进行电压折算(电压平方)(2)采用程序计算:按测量参数计算(3)判断转子匝间短路:测量值大于计算值,差值大于2%以上机号日期有功P无功QcosΦ电压U电流I励磁电流A(MW)(Mvar)(V)(A)测量值DCS程序计算查V形曲线36-128:52528159.80.962203731555033133340332046-129:23529.5166.10.9552044215659336233833342发电机V形曲线(设计值)励磁电流的数值计算计算原理见《中国电力》2003年第8期《汽轮发电机负载运行下励磁电流的数值计算方法和程序》一文转子绕组平均温度计算(电阻法)转子热电阻R2=Uf/If(不考虑电刷压降)15℃转子冷电阻3号机R15=0.0757Ω(出厂试验值)4号机R15=0.0755Ω(出厂试验值)转子绕组平均温度T2=(R2/R15)×250-235机号日期UfIfR2R15T2允许温度VAΩΩ℃℃36-12304.633130.091940.075768.611046-12309.533620.092060.075569.8110温度参数定子铁心温度:铜-康铜热电偶16支对称分布:限值120℃。氢气温度:Pt-100铂电阻4支汽端和励端冷热风温各一支冷风46℃(限值40-48℃)两台冷却器出风温差不超过2k。空气温度:Pt-100铂电阻4支励端集电环进出风温各一支进风温度45℃(最大50℃)。集电环温度:限值120℃(红外热像仪测量)励端端部中部铁心汽端端部部位磁屏蔽齿压板铁心齿铁心齿铁心轭磁屏蔽齿压板铁心齿数量22222222铁心温度分布机号时间负荷电压2007-6-13MWkV冷风热风珠海1号机684.122.072.276.483.3****79.7****90.589.3****84.884.871.284.071.082.081.083.084.038.065.0珠海2号机590.522.063.960.069.267.965.962.680.077.864.171.573.774.776.573.366.767.266.369.837.760.02007-6-26珠海1号机679.922.072.075.083.0****78.0****94.092.0****87.087.073.085.072.080.079.085.086.037.066.9珠海2号机699.922.168.065.077.073.072.067.092.090.072.081.085.086.092.087.079.080.079.085.037.067.92007-6-18负荷电压MWkV齿部齿部齿部轭部齿部轭部齿部齿部冷风热风冷风热风珠海3号机600.020.452.053.068.069.067.068.055.053.041.040.043.044.042.041.043.044.040.047.040.045.0珠海4号机600.020.453.053.072.072.073.073.053.055.039.040.041.042.042.041.043.044.038.046.039.045.0台电1号机49.047.796.091.895.590.952.551.943.344.246.245.744.945.850.950.242.550.742.451.0台电2号机43.543.268.868.984.684.042.043.242.742.844.645.343.442.744.246.042.350.142.246.9台电3号机46.245.881.481.279.880.846.945.642.042.043.644.844.043.244.445.041.846.241.446.6台电4号机48.348.282.082.883.484.246.447.444.844.847.647.445.044.245.845.643.253.242.049.7台电5号机47.148.080.281.680.481.845.446.643.643.846.446.643.643.245.847.042.047.542.647.8汽端铁心温度℃汽端磁屏蔽温度℃集电环端磁屏蔽温度℃汽端中部定子铁心温度℃端部磁屏蔽齿压板温度℃风温℃汽端励端风温℃汽端statorcore(turbineend)temp磁屏蔽励端齿压板statorcore(turbineend)shieldtemp励端磁屏蔽齿压板statorcore(collectorend)shieldtemp定子线圈温度定子线圈层间温度Pt-100铂电阻42支(备用42支)限值:90℃或温差10k报警温差14k跳闸定子线圈出水温度:铜-康铜热电偶线圈84支(上下层各42支),并联环-主引线-出线套管6支线圈出水温度:同层85℃或温差8k报警90℃或温差12k跳闸出线套管出水温度:85℃报警90℃跳闸定子总进出水温度:镍铬-康铜热电偶4支进水温度大于冷氢温,在45-50℃之间总出水温度大于85℃或对进水的温升大于31k报警定子冷却水运行参数流量:总流量大于105m3/h80%报警出线盒流量大于12m3/h80%报警水压:0.3~0.35MPa小于氢压35kPa总进出水管压差:0.205MPa(105m3/h时)超过值大于35kPa报警水电导率:小于1.5μs/cm大于5μs/cm报警PH值:7.0~9.0硬度:小于2μmol/L600MW时定子温度典型值定子进水40℃线圈出水55℃套管出水48℃线圈层间58℃冷氢温度40℃热氢温度47℃中部铁心72℃端部铁心55℃磁屏蔽42℃齿压板45℃氢气参数氢气纯度:95%以上(低于90%报警)氢气纯度测量氢气压力额定氢压:0.4MPa(额定负载小于0.38MPa,大于0.44MPa报警)氢气湿度湿度高(1)降低氢气纯度,增加损耗,效率降低(2)降低电气绝缘强度(3)加速转子护环应力腐蚀湿度过低:绝缘材料收缩,干裂降低湿度的设备:LQS-ⅡCS型冷冻式氢气干燥器(设置两台:一台干燥运行,一台化霜)氢气温度绝对湿度露点相对湿度℃g/m3℃%期望值402-114允许范围404-0.550~-2510-1氢气湿度计漏氢监测装置漏氢监测8点:封闭母线A,B,C,中性点O,O,定冷水箱,励端轴承回油,汽端轴承回油。仪器:JKL-8型可编程漏氢自动检测装置报警值:3.2%(空气中的氢气含量)JKL-8型可编程漏氢自动检测装置油水捡漏器:5支(励侧3支,汽侧2支),设置报警信号FJR-ⅡA型发电机绝缘过热监测装置密封油参数进油温度:45℃(40~49℃)振动大时(46~48℃空侧和氢侧油温差:2k(振动大时1k)氢油压差:0.084MPa(0.056~0.097MPa)氢侧和空侧油压差:小于490Pa氢侧出油温度:小于65℃空侧出油温度:小于56℃轴承运行参数轴承润滑油进油温度:38℃(27~49℃)出油温度:65℃(60~71℃)77℃报警润滑油压力:0.1MPa(0.08~0.12MPa)轴瓦温度:70℃(65~77℃)(99℃报警)7瓦8瓦相对轴振:80μm(127μm报警254μm跳闸)9瓦相对轴振:100μm(127μm报警254μm跳闸)X(相对轴振)Y(相对轴振)轴承座振动转向45º45º从汽机机头方向看电涡流位移传感器复合传感器KΦ(键相传感器)轴承振动传感器布置
本文标题:汽轮发电机教材-4运行参数
链接地址:https://www.777doc.com/doc-4002366 .html