您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 家电行业 > 导线力学计算书110kV上层出线
软导线力学计算报告工程名称:设计阶段:单位:设计人:资料编号:计算时间:一.设计参数:最大放线弧垂fmax:0.9(m)短路电流有效值I:(kA)次导线分裂间距:(cm)次导线初始张力:(kgf)左跨编号:右跨编号:跨编号:-导线型号:LGJ-630/55导线档距:10.150(m)导线高差:0.000(m)导线cosγ:1.000导线计算直径D(mm):34.320导线计算截面S:696.220(mm^2)导线温度线膨胀系数ax:20.500(1/℃)xE-6导线弹性模量E:65000.000左绝缘子串型号:XW-4.5(8)左绝缘子串长度:1.620右绝缘子串型号:XW-4.5(8)右绝缘子串长度:1.620三相上人位置:0.000(m)三相上人荷载:100.000(kgf)单相上人位置:0.000(m)单相上人荷载:150.000(kgf)序号状态温度℃风速(m/s)覆冰厚度(mm)1最高温度:80002最低温度:-5003最大风速:103504最大荷载:-51005施工安装:401006施工安装:351007施工安装:301008施工安装:251009施工安装:2010010施工安装:1510011施工安装:1010012施工安装:510013施工安装:010014施工安装:-510015施工安装:-1010016施工安装:-1510017施工安装:-2010018施工安装:-2510019施工安装:-3010020施工安装:-3510021施工安装:-4010022三相上人:010023三相上人:1010024单相上人:010025单相上人:10100二.导线和绝缘子串的单位荷重主导线在各工作况下的单位荷重(1)导线自重q1=2.209(kgf/m)(2)导线冰重q2=0.00283*b*(d+b)=0.0283*0*(34+0)=0.000kg(f/m)(3)导线自重及冰重q3=q1+q2=2.209+0.000=2.209(kgf/m)(4)导线所受风压q4=0.075*Vf^2*d*1.0e-3=0.075*35^2*34*1.0e-3=3.153(kgf/m)q4'=0.075*Vf'^2*d*1.0e-3=0.075*10^2*34*1.0e-3=0.257(kgf/m)(5)导线覆冰时所受风压q5=0.075*Vfb^2*(d+2b)*1.0e-3=0.075*10^2*(34+2*0)*1.0e-3=0.257(kgf/m)(6)导线无冰时自重与风压的合成荷重q6=sqrt(q1^2+q4^2)=sqrt(2.209^2+3.153^2)=3.850(kgf/m)q6'=sqrt(q1^2+q4'^2)=sqrt(2.209^2+0.257'^2)=2.224(kgf/m)(7)导线覆冰时自重、冰重与风压的合成荷重q7=sqrt(q3^2+q5^2)=sqrt(2.209^2+0.257^2)=2.224(kgf/m)左绝缘子串在各种工况下的荷重(1)绝缘子串自重:q1=56.000(kgf)(6)绝缘子串无冰时,自重与风压的合成荷重q6=56.581(kgf)q6p=56.004(kgf)(7)绝缘子串覆冰时自重、冰重与风压的合成荷重q7=56.004(kgf)右绝缘子串在各种工况下的荷重(1)绝缘子串自重:q1=56.000(kgf)(6)绝缘子串无冰时,自重与风压的合成荷重q6=56.581(kgf)q6p=56.004(kgf)(7)绝缘子串覆冰时自重、冰重与风压的合成荷重q7=56.004(kgf)左跳线在各工作况下的单位荷重(1)导线自重q1=2.209(kgf/m)(2)导线冰重q2=0.00283*b*(d+b)=0.0283*0*(34+0)=0.000kg(f/m)(3)导线自重及冰重q3=q1+q2=2.209+0.000=2.209(kgf/m)(4)导线所受风压q4=0.075*Vf^2*d*1.0e-3=0.075*35^2*34*1.0e-3=3.153(kgf/m)q4'=0.075*Vf'^2*d*1.0e-3=0.075*10^2*34*1.0e-3=0.257(kgf/m)(5)导线覆冰时所受风压q5=0.075*Vfb^2*(d+2b)*1.0e-3=0.075*10^2*(34+2*0)*1.0e-3=0.257(kgf/m)(6)导线无冰时自重与风压的合成荷重q6=sqrt(q1^2+q4^2)=sqrt(2.209^2+3.153^2)=3.850(kgf/m)q6'=sqrt(q1^2+q4'^2)=sqrt(2.209^2+0.257'^2)=2.224(kgf/m)(7)导线覆冰时自重、冰重与风压的合成荷重q7=sqrt(q3^2+q5^2)=sqrt(2.209^2+0.257^2)=2.224(kgf/m)右跳线在各工作况下的单位荷重(1)导线自重q1=2.209(kgf/m)(2)导线冰重q2=0.00283*b*(d+b)=0.0283*0*(34+0)=0.000kg(f/m)(3)导线自重及冰重q3=q1+q2=2.209+0.000=2.209(kgf/m)(4)导线所受风压q4=0.075*Vf^2*d*1.0e-3=0.075*35^2*34*1.0e-3=3.153(kgf/m)q4'=0.075*Vf'^2*d*1.0e-3=0.075*10^2*34*1.0e-3=0.257(kgf/m)(5)导线覆冰时所受风压q5=0.075*Vfb^2*(d+2b)*1.0e-3=0.075*10^2*(34+2*0)*1.0e-3=0.257(kgf/m)(6)导线无冰时自重与风压的合成荷重q6=sqrt(q1^2+q4^2)=sqrt(2.209^2+3.153^2)=3.850(kgf/m)q6'=sqrt(q1^2+q4'^2)=sqrt(2.209^2+0.257'^2)=2.224(kgf/m)(7)导线覆冰时自重、冰重与风压的合成荷重q7=sqrt(q3^2+q5^2)=sqrt(2.209^2+0.257^2)=2.224(kgf/m)三.各状态下的荷载:主导线:LGJ-630/551最高温度:2.209(kgf/m)2最低温度:2.209(kgf/m)3最大风速:3.850(kgf/m)4最大荷载:2.224(kgf/m)5施工安装:2.224(kgf/m)6施工安装:2.224(kgf/m)7施工安装:2.224(kgf/m)8施工安装:2.224(kgf/m)9施工安装:2.224(kgf/m)10施工安装:2.224(kgf/m)11施工安装:2.224(kgf/m)12施工安装:2.224(kgf/m)13施工安装:2.224(kgf/m)14施工安装:2.224(kgf/m)15施工安装:2.224(kgf/m)16施工安装:2.224(kgf/m)17施工安装:2.224(kgf/m)18施工安装:2.224(kgf/m)19施工安装:2.224(kgf/m)20施工安装:2.224(kgf/m)21施工安装:2.224(kgf/m)22三相上人:2.224(kgf/m)23三相上人:2.224(kgf/m)24单相上人:2.224(kgf/m)25单相上人:2.224(kgf/m)左绝缘子:XW-4.5(8)1最高温度:56.000(kgf)2最低温度:56.000(kgf)3最大风速:56.581(kgf)4最大荷载:56.004(kgf)5施工安装:56.004(kgf)6施工安装:56.004(kgf)7施工安装:56.004(kgf)8施工安装:56.004(kgf)9施工安装:56.004(kgf)10施工安装:56.004(kgf)11施工安装:56.004(kgf)12施工安装:56.004(kgf)13施工安装:56.004(kgf)14施工安装:56.004(kgf)15施工安装:56.004(kgf)16施工安装:56.004(kgf)17施工安装:56.004(kgf)18施工安装:56.004(kgf)19施工安装:56.004(kgf)20施工安装:56.004(kgf)21施工安装:56.004(kgf)22三相上人:56.004(kgf)23三相上人:56.004(kgf)24单相上人:56.004(kgf)25单相上人:56.004(kgf)右绝缘子:XW-4.5(8)1最高温度:56.000(kgf)2最低温度:56.000(kgf)3最大风速:56.581(kgf)4最大荷载:56.004(kgf)5施工安装:56.004(kgf)6施工安装:56.004(kgf)7施工安装:56.004(kgf)8施工安装:56.004(kgf)9施工安装:56.004(kgf)10施工安装:56.004(kgf)11施工安装:56.004(kgf)12施工安装:56.004(kgf)13施工安装:56.004(kgf)14施工安装:56.004(kgf)15施工安装:56.004(kgf)16施工安装:56.004(kgf)17施工安装:56.004(kgf)18施工安装:56.004(kgf)19施工安装:56.004(kgf)20施工安装:56.004(kgf)21施工安装:56.004(kgf)22三相上人:56.004(kgf)23三相上人:56.004(kgf)24单相上人:56.004(kgf)25单相上人:56.004(kgf)左跳线:LGJ-630/55荷载=单位荷载*长度+线夹重1最高温度=2.209*5.000+10.000=21.0452最低温度=2.209*5.000+10.000=21.0453最大风速=3.850*5.000+10.000=29.2504最大荷载=2.224*5.000+10.000=21.1205施工安装=2.224*5.000+10.000=21.1206施工安装=2.224*5.000+10.000=21.1207施工安装=2.224*5.000+10.000=21.1208施工安装=2.224*5.000+10.000=21.1209施工安装=2.224*5.000+10.000=21.12010施工安装=2.224*5.000+10.000=21.12011施工安装=2.224*5.000+10.000=21.12012施工安装=2.224*5.000+10.000=21.12013施工安装=2.224*5.000+10.000=21.12014施工安装=2.224*5.000+10.000=21.12015施工安装=2.224*5.000+10.000=21.12016施工安装=2.224*5.000+10.000=21.12017施工安装=2.224*5.000+10.000=21.12018施工安装=2.224*5.000+10.000=21.12019施工安装=2.224*5.000+10.000=21.12020施工安装=2.224*5.000+10.000=21.12021施工安装=2.224*5.000+10.000=21.12022三相上人=2.224*5.000+10.000=21.12023三相上人=2.224*5.000+10.000=21.12024单相上人=2.224*5.000+10.000=21.12025单相上人=2.224*5.000+10.000=21.120右跳线:LGJ-630/55荷载=单位荷载*长度+线夹重1最高温度=2.209*0.000+0.000=0.0002最低温度=2.209*0.000+0.000=0.0003最大风速=3.850*0.000+0.000=0.0004最大荷载=2.224*0.000+0.000=0.0005施工安装=2.224*0.000+0.000=0.0006施工安装=2.224*0.000+0.000=0.0007施工安装=2.224*
本文标题:导线力学计算书110kV上层出线
链接地址:https://www.777doc.com/doc-4075904 .html