您好,欢迎访问三七文档
防撞墙施工方案编制:校对:审核:二○一○年三月1目录一、概况...........................................................................................................................................11.1主要工程量........................................................................................错误!未定义书签。1.2结构形式............................................................................................................................1二、工期安排及施工准备...............................................................................................................12.2人员组织............................................................................................................................22.3机械设备配置....................................................................................................................2三、施工组织...................................................................................................................................33.1、防撞墙施工工艺.............................................................................................................33.2样板段选择........................................................................................................................33.3施工方法及质量标准........................................................................................................33.3.1施工前准备....................................................................................................................43.3.2钢筋制作与安装............................................................................................................43.3.3预埋件安装....................................................................................................................53.3.4模板安装........................................................................................................................53.3.5砼浇筑与养护................................................................................................................63.4质量标准............................................................................................................................7四、质量保证措施...........................................................................................................................7五、安全、文明施工及环境保护措施...........................................................................................85.1安全保证措施....................................................................................................................85.2文明施工和环境保护措施................................................................................................9六、附:挂篮验算.........................................................................................................................106.1挂篮的结构形式..............................................................................................................106.2挂篮的稳定性验算..........................................................................................................116.3挂篮三维效果图..............................................................................................................121防撞墙施工方案一、概况1.2结构形式本工程采用墙式防撞墙结构,两种结构形式其横断面形式见下图:二、工期安排及施工准备2.1工期安排根据总体施工计划的安排,本部将充分考虑到各种影响工期的不确定要素,科学合理地安排施工进度,保证按业主计划在合同期内完工。具体开、竣工日期为:序号桥梁名称计划开工计划完工备注1K3桥2010-3-202010-5-103K4+166桥2010-3-182010-4-204K6+624桥2010-3-182010-4-155K7+302桥2010-6-12010-6-206K9+070桥2010-3-152010-4-57A匝道桥2010-3-182010-5-31墙式护拦断面1墙式护拦断面228B匝道桥2010-4-202010-5-209C匝道桥2010-4-102010-5-3110D匝道桥2010-4-52010-4-3011E匝道桥2010-3-182010-5-3112F匝道桥2010-4-202010-5-252.2人员组织防撞墙砼施工,配置管理人员9人,钢筋工60人,木工15人,泥水工及杂工75人。主要管理人员表序号岗位姓名备注1施工负责人沈健2技术负责人王昕政6现场施工负责袁璞2工区3质量负责人张良文4测量负责人马际5专职安全员瞿志云7现场施工员黄胜8现场施工员高阳9测量员金易2.3机械设备配置主要机械设备表序号机械名称规格型号额定功率(KW)或容量或吨位数量1钢筋加工机械4套3木工机械4套5插入振动棒3、5cm各10套3三、施工组织3.1防撞墙施工工艺施工工艺流程图3.2样板段选择本项目部选择K9+070桥作为防撞墙样板段施工,防撞墙长度360米,有3个路灯基础,防撞墙形式为墙式护栏1。将本桥作为防撞墙的首次施工段落,合理组织施工,严格履行监理验收制度,验证施工工艺的合理性,发现和解决施工中存在的问题,总结和优化施工工艺,为后续大面积施工提供了技术依据,确保防撞墙施工质量满足设计及规范要求。3.3施工方法及质量标准在防撞墙施工前一定要安装好桥面排水口。防撞墙采用定制钢模分段拼装浇注,模板安装采用无支架吊篮作业,节约工时,安全可靠,快捷便利。模板安装砼浇筑预埋件加工拆模养身测量放样钢筋加工及安装施工准备模板加工预埋件安装43.3.1施工前准备(1)桥面排水口及桥面铺装施工在防撞墙施工前一定要安装好桥面排水口第一节管道,排水管四周应将砂浆填塞密实并将表面砂浆受水压光,排水口要有一定的坡度利于汇水与排水。如果桥面铺装砼在防撞墙之前施工,则注意要在离防撞墙内侧底部30cm不浇筑混凝土,在施工防撞墙时浇筑砂浆,用于控制模板底标高,待防撞墙施工完毕后,铲除重新浇筑C40混凝土。(2)模板制作根据设计要求的尺寸、线形,选择有经验、有资质、信得过的生产厂家加工钢模板。模板加工要有足够的刚度和强度,不易变形,钢板转角处应采用压模处理,以保证板面光滑、线形圆顺,面板钢材厚度应大于4mm,加工时不允许采用碎钢板拼接板面,确保浇筑的砼表面光洁。为了保证曲线段防撞墙线形顺畅,应适当加工一些短模板来调整线形。本工程单块长度主要为1.5m,在弧度比较小的地方制作几个长度比较小的单块。模板制作好之后,预拼装,验收合格后,在模板上注上显目的编号。(3)测量放样在施工前先应根据设计要求测量放出的护栏内边线,并分别向桥面内引出20cm作为校核模板和做调整的基准线。外引线用墨线弹出明确的线形,作为控制模板的标志线。对模板局部出现反向线形现象时,应该调整对应点位尺寸(在保证桥面净宽的前提下),使得护栏线型圆顺、美观。3.3.2钢筋制作与安装护栏的钢筋与梁体内预埋的钢筋焊接,满足焊接长度5d(双面焊),10d(单面焊)要求,焊缝饱满。在加工护栏钢筋时一定注意要保证防撞墙的钢筋净保护层厚3cm。在焊接一段钢筋时在钢筋顶部拉一条线,控制好钢筋顶面,防止护栏顶部钢筋出现波浪状,并且护栏的通长钢筋应在桥面连续缝和伸缩缝位置断开。53.3.3预埋件安装在绑扎防撞墙钢筋的同时,要特别注意防撞墙内的预埋件,本工程预埋件包括照明及通讯穿管、路灯基础预埋件、接线箱等。要按照设计要求施工,电力与通讯施工单位配合,现场跟踪指导,保证预埋件位置的准确,在安装模板之前必须特别检查,还要注意桥面排水通道位置。钢筋绑扎后在立模时应设置垫块,保证防撞墙砼保护层厚度为3cm。3.3.4模板安装模板采用无支架挂篮法施工。模板安装加固采取“夹、拉、顶、压”的方法对模板进行加固,确保模板稳固不变形。模板安装根据弹出的墨线恢复护栏内边线,先安装和加固好内侧模板,内模安装时底部面板内侧和内边墨线相吻合,内模加固采用在内模内侧用Ф16的钢筋做定位钢筋焊在底部主筋上顶住内模,外侧采用钢管顶住模板,形成内外双夹的形式卡住模板
本文标题:防撞护栏施工方案3
链接地址:https://www.777doc.com/doc-4241176 .html