您好,欢迎访问三七文档
公用实验平台仪器操作规程与注意事项目录1.GG79-EasypureBarnstead超纯水器..........................................................................................22.YX-280型手提式压力蒸汽灭菌器.............................................................................................33.HH-W600数显三用恒温水箱....................................................................................................44.VORTEX-5旋涡混合器.............................................................................................................55.SKG-02型电热恒温干燥箱........................................................................................................66.JJ-1(A)型精密定时电动搅拌器...................................................................................................87.TG16-WS台式高速离心机........................................................................................................98.GL-1800型干式恒温器.............................................................................................................119.DYCP-6C型电泳仪....................................................................................................................1410.GL-3250A型磁力搅拌器.........................................................................................................1611.流式细胞仪操作规程..............................................................................................................1712.LEICACM1900型冰冻切片机..............................................................................................2113.实时定量PCR仪(7300)......................................................................................................2314.BeckmanAllegra64R高速冷冻离心机...................................................................................2815.SONICSVCX750超声波破碎仪...........................................................................................3016.TS-1脱色摇床..........................................................................................................................3117.UNICOUV-2800型紫外可见分光光度计............................................................................3218.YP6002型电子天平(600g/0.01g)............................................................................................3519.梅特勒-托利多AL104型电子天平........................................................................................3820.凝胶成像系统..........................................................................................................................4021.美国NUAIRE公司蓝色冰川系列低温冰箱...........................................................................4122.DL-CJ-1ND超净工作台...........................................................................................................4223.96通道高级锋电位分拣系统..................................................................................................4324.NeuroscanEEG/ERP系统.......................................................................................................4425.虚拟实验系统..........................................................................................................................4726.高架十字迷宫..........................................................................................................................4827.操作性条件反射箱..................................................................................................................5128.Morris水迷宫............................................................................................................................5311.GG79-EasypureBarnstead超纯水器操作方法:1、检查注水桶内原水(蒸馏水或去离子水)是否浸没仪器进水管;2、将电源插头插入带有接地线的220V电源插座上;3、开机:依次按下电源开关,纯水机启动产水开关(START/STOP);4、取纯水:打开纯水机的出口阀门,则可获得相应水质的纯水。当高纯水出口阀门打开时,检测仪表显示高纯水电导率或电阻值。为了获得高质量的高纯水,可以先放掉一杯水后再取新鲜水。待出水阻力为18.2MΩ/cm时,可从出水口采高纯水;5、采水完毕,按START/STOP;6、将纯水机的出口阀门关上;7、关闭电源。22.YX-280型手提式压力蒸汽灭菌器一、使用方法:1、加水:取出内灭菌筒,在外灭菌筒内加水3.5升即可使用,循环使用必须补足额定水量,以防缺水烧坏电热管;2、堆放:把灭菌物放入内菌筒的筛板上,包扎的灭菌物品之间要留有空隙,以利蒸汽渗透,提高灭菌质量;3、密封:将内灭菌筒放入容器内,然后把容器盖上的软管插入灭菌筒内半圆槽中,容器盖与容器上的翼形螺母对称旋紧,使盖与容器密合;4、加热:将电源接线插于电源座上,打开开关加热开始,此时应将放气阀及安全阀汽帽板起,使灭菌器桶内冷空气逸出,桶内温度达100℃以上(压力0.05MPa),待有较急的蒸气喷出,将二阀汽帽复原;5、冷却:当灭菌终了后,应先关闭电源,待其冷却到压力表读数回复到零位后再打开放气阀和容器盖。切勿在灭菌终了时立即打开放气阀或容器盖,以免沸腾的溶液溢出,造成事故。二、注意事项1、每次使用前,应检查主体内有足够水量,使水位超过电热管。2、在开始加热时,应将放气阀塞子置于垂直“放气”位置,使桶内的冷空气随着加热逸出。3、灭菌液体时,应将溶液灌装在硬质的耐热玻璃瓶中,应不超过3/4体积为好。瓶口用棉花、纱布塞好,并用纱绳扎在瓶颈上,在加热时使瓶内的空气能自然泄出,切勿使用未打孔的橡胶塞和硬木塞。昀好能将玻璃瓶放在容积比较大的搪瓷或金属盘内,以防万一瓶子爆裂时液体流失和损坏灭菌器内壁。4、应特别注意:灭菌终了时切勿立即释放蒸汽,应按程序操作以免发生事故。5、灭菌终了时,若压力表指针已回复零位,而不易启时,将放汽阀塞子置于“放汽”方位,使外界空气进入灭菌器内,真空消除后,盖即可开启。6、橡胶密封垫圈使用日久会老化,应及时检查并定期更换。7、使用结束应立即关闭电源。33.HH-W600数显三用恒温水箱尺寸600×300×210,室温~100℃,加热功率1500W一、操作前检查1、摆放是否平稳,锅内是否加入水;2、电源是否正常。二、使用方法使用时必须先加水于锅内,再接通电源,然后把温度选择开关拨向设置,调节温度选择按钮同时观察数显读数所需的温度值(精确到0.1℃),当设置温度值超过水温时,加热指示灯亮,表明加热器开始工作,此时把选择开关拨向测量端,数显即显示实际水温,当水温达到你所需温度时,恒温指示灯亮,加热指示灯熄,此时,加热已停止工作,由于锅内水是静止的,故水温上下之间有一定差别,需经过几次加热、恒温转换后才能达到均刀恒定(此过程不需要进行任何操作,即能自动完成),锅内不可加水过多,以免沸腾时水量溢出锅外,并应注意锅内水不能使电热管露出水面,以免烧坏电热管,造成漏水。三、注意事项1、昀低水位不能低于电热管,以免烧毁,亦不可加水过多,以免溢出锅外;2、控温系统控温仪如有损坏,应更换同规格型号的控温仪;3、锅内须保持清洁,不用时应放在通风干燥处;4、该产品使用220V交流电,电源采用三脚安全插头,其中一只昀长的脚,为安全接地脚,为此应使用的三眼插座应妥善接地;5、由于水箱内加温时水温上下温度较大,所以当需要温度计测量时,一定要待水温在稳定状态时测量;6、加热管之间有一根不锈钢金属管作温度传感器,切勿碰撞,以免控
本文标题:仪器操作说明
链接地址:https://www.777doc.com/doc-4276994 .html