您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 给排水/暖通与智能化 > 供热系统调试方案
郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-1-河南第一火电建设公司调试所1编号:8080-HNHY-TSJ-A05-23河南第一火电建设公司调试所调试作业指导书工程名称:郑东新区一期2×200MW机组工程项目名称:供热系统调试方案编制单位:河南第一火电建设公司调试所出版日期:2007年07月19日郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-2-河南第一火电建设公司调试所2工程名称郑东新区热电厂一期2×200MW机组工程文件名称供热系统调试方案文件类别分系统试运批准年月日审核年月日编制年月日郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-3-河南第一火电建设公司调试所3目录1目的···························································································(04)2依据···························································································(04)3设备及系统简介·······································································(04)4调试内容及验评标准·······························································(06)5组织分工··················································································(06)6使用仪器设备··········································································(06)7调试应具备的条件··································································(06)8调试步骤··················································································(07)9优化措施及建议····································································(09)10联锁保护···············································································(09)11安全注意事项········································································(09)郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-4-河南第一火电建设公司调试所41目的为了检验热网系统运行可靠性,保证系统试运顺利进行,为供热打下良好的基础,特制定本措施。2依据2.1《火电机组达标投产考核标准(2001年版)》。2.2《火力发电厂基本建设工程启动及竣工验收规程(1996年版)》。2.3《火电工程调整试运质量检验及评定标准(1996年版)》。2.4《电力建设施工及验收技术规范(汽轮机组篇)》2.5《火电工程启动调试工作规定》。2.6《电力基本建设工程质量监督规定》。2.7《电力建设安全健康与环境管理工作规定(2002年版)》。2.8《郑东新区热电厂2×200MW机组工程调试大纲》。2.9《工程建设强制性条文(电力工程)》。2.10《电业建设安全工作规程(热力机械部分)》。2.11设备厂家、设计单位提供的有关图纸资料。3设备及系统简介郑东新区热电厂2×200MW工程设计为两台双抽汽供热机组,向热网用户供热。每台机组从汽轮机的五段抽汽引出一路作为供热抽汽,额定抽汽压力为0.245MPa。供热抽汽送至热网加热器加热热网循环水,通过热网循环水向热用户供热。系统设计有4台热网加热器,用于汽水换热;4台热网循环水泵,向热用户供热水;4台热网疏水泵,将热网加热器内蒸汽凝结的水送到除氧器。3.1主要设备技术参数3.1.1热网疏水泵热网疏水泵热网疏水泵电机型号250NW—47*3型号Y2-315L1-4转速(r/min)1480转速(r/min)1478流量(m3/h)260电压(V)380/660扬程(m)140功率(KW)185郑东新区热电有限公司一期2×200MW机组工程5汽蚀余量(m)2.9电流(A)32.7/189功率因数0.89生产厂家上海凯泉泵业有限公司生产厂家佳木斯电机股份有限公司3.1.2热网循环水泵热网循环水泵热网循环水泵电机型号KQSN400—M6/725(T)型号YKK5602—4转速(r/min)1480转速(r/min)1480流量(m3/h)3000电压(V)6000扬程(m)168功率(KW)1400必需汽蚀余量(m)5.0电流(A)160.6效率(%)85功率因数0.883.1.3热网加热器型号RJBL—1500—1.8—4换热面积1500m2设计温度设计压力耐压试验压力设计流量介质℃MPaMPaT/H管程1801.92.851600水壳程2600.450.675180水蒸汽3.1.4电动除污器型号QLS—36L—0.6管径DN900工作压力MPa0.35设计压力MPa0.6工作温度℃100设计温度℃120生产厂家武汉华源电力设备有限公司3.2系统流程:3.2.1热网循环水化学水补水热网循环水泵进口热网循环水泵热网加热器水侧热网回水母管热用户热网供水母管供热系统调试方案-5-河南第一火电建设公司调试所郑东新区热电有限公司一期2×200MW机组工程63.2.2供热抽汽供热抽汽热网加热器汽侧热网疏水泵除氧器定排4调试内容及验评标准4.1调试内容4.1.1热网循环水泵电机单体试转。4.1.2热网循环水泵试转及投运。4.1.3热网疏水泵单体试转及投运。4.1.4热网加热器投入运行。4.2验评标准4.2.1泵轴承振动小于80um。4.2.2电流指示不大于额定电流。4.2.3泵组轴承温度小于90℃。4.2.4供热抽汽参数满足要求。4.2.5质量验评表。5组织分工5.1调试人员负责编写方案,指导运行人员操作,检查系统应具备的条件。5.2安装单位负责设备、系统安装及维护。5.3运行人员负责检查、倒系统、设备的操作。6使用仪器设备设备名称型号数量用途备注1便携测振仪VM-63A1振动测量2红外线测温仪Raymx2c1温度测量7调试应具备的条件7.1热网系统设备及管道已安装完毕,并经验收合格,具备通水通汽条件。7.2系统内所有水管道冲洗干净,热网加热器水侧冲洗干净。7.3系统上的各电动门、抽气逆止阀、快关阀调试完毕,各手动门应开关灵活,所有安供热系统调试方案-6-河南第一火电建设公司调试所郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-7-河南第一火电建设公司调试所7全门冷态整定完毕。7.4通过热网补水管路向热网管道补水,空气放净,检查无泄漏。7.5冷却水系统试运正常,排污管道畅通。7.6各热工仪表、就地表计及信号音响装置安装齐全,并经校验调整准确,联锁保护装置试验正常。7.7电机单体试转4小时正常,与泵连接完毕,对轮防护罩完好。7.8试运现场道路畅通、照明充足,通讯设施完善,可靠。7.9参加试运人员应分工明确,统一指挥。7.10试运现场已清扫干净,孔洞盖好,护栏、梯子、扶手齐全。7.11试运现场安全及消防设施落实到位。7.12系统所有管道应挂牌并标注名称。7.13动力、仪控电源具备投入条件。7.14夏季试运应有防暑降温措施;冬季试运应有相应的防冻措施。8调试步骤8.1热工信号及联锁保护检查试验热工信号及联锁保护试验合格后,协调热工专业人员、运行人员和监理对该试验记录进行合格检查,并做好检查记录。8.2热网循环水泵试运转及投运8.2.1确保以上试运检查项目都已做出,并检查系统完整性。8.2.2检查热网循环水泵轴承润滑油脂正常,工业冷却水正常投入。8.2.3检查填料压紧程度应均匀,不要过紧或过松;手盘转子应灵活,无摩擦和卡涩现象。8.2.4热网管道系统充满水,热网加热器及管道排空气。8.2.5系统回路正常,与外围管道的负责单位联系完毕。8.2.6启动热网循环水泵,稍开热网循环水泵出口门,注意泵电流、振动、泵出口压力、加热器水侧压力。8.2.7观察热网循环水泵进口压力,若下降太多,应及时向热网系统补水;当此压力升高并稳定后,才可缓慢打开热网循环水泵出口门。8.2.8检查热网系统各设备和管道有无泄漏,一切正常后,运行8小时以上。8.3供热抽汽试运郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-8-河南第一火电建设公司调试所88.3.1汽侧投入前,加热器水侧必须投入且运行正常。8.3.2热网供热汽源来自汽轮机五段抽汽,当汽轮机启动运行后,负荷带到70%(140MW)时,抽气供热投入运行,向热网加热器汽侧供汽。8.3.3抽汽供热投入时,抽汽点压力经调压器调整后,应略高于与供热相联的阀门后的压力方可投入。8.3.4供汽前,打开热网加热器紧急放水门,使热网加热器疏水通过放水管道排至锅炉定排罐。8.3.5供汽前先打开供热抽汽管道疏水门,充分疏水,然后打开供热抽汽快关阀和逆止阀,对供热抽汽管道暖管。8.3.6稍开热网加热器进汽门,向热网加热器汽侧供汽暖体,待热网加热器汽侧充分暖热后,再开大热网加热器进汽门,正式供汽。8.3.7供汽时注意观察热网加热器汽侧和水侧温度,要控制热网加热器进汽量,使热网供水温度达到90~120℃即可。8.3.8若五段抽汽压力过低,可投入抽汽压力调节,通过DEH系统控制汽机供热蝶阀开度,调节供热抽汽压力,注意供热蝶阀后的压力不得低于0.049MPa,以保证足以通过低压缸冷却流量2×44t/h,确保低压末级叶片安全运行。8.3.9注意汽侧水位情况。8.4热网疏水泵试运8.4.1热网加热器汽侧投用后,疏水先经过紧急放水管道排向定排疏水扩容器,待水质合格后才可经热网疏水泵打回汽机凝结水管道,予以回收。8.4.2打开热网疏水泵进、出口门。8.4.3启动热网疏水泵,打开热网疏水至除氧器手动门和调节门,回收热网凝结水。8.4.4运行时,用热网疏水至除氧器管道上的调节门控制热网加热器水位。8.5抽汽供热工况的切除8.5.1将供热工况切换到纯冷凝工况运行,应将供热蝶阀逐渐开启,热负荷逐渐减小。待供热蝶阀全开后,关闭热网加热器进汽电动截止阀、供热抽汽逆止阀、供热快关阀,机组转为纯冷凝工况运行。8.5.2机组在供热工况下甩负荷时关闭供热抽汽逆止阀、供热快关阀、热网加热器进汽电动阀切除供热压力调节系统,关闭供热蝶阀至全关位置持续2~4秒,控制程序确认供热阀门关闭后,缓慢开启供热蝶阀至全开,机组维持空转,整个过程由调节系统自动控制。郑东新区热电有限公司一期2×200MW机组工程供热系统调试方案-9-河南第一火电建设公司调试所9甩负荷后2分钟内供热蝶阀不能开启时应立即打闸停机。8.5.3机组在供热工况下紧急停机。切除供热压力调节系统;关闭供热蝶阀;关闭热网加热器进汽电动阀、供热抽汽逆止阀、供热快关阀。8.5.4机组负荷低于70%额定负荷时,应切除热负荷。9优化措施及建议9.1热网水侧管道在冲洗过程中,由于外围管道较长,杂物较多,必须经过电动除污器后才可以进入加热器。根据除污器前后压差,及时清理除污器内杂物。9.2加热器汽侧投入前暖管疏水要充分,加热温升不能太快,防止管道膨胀不充分。10联锁保护10.1机组停机时联关热网加热器进汽电动截止阀、供热抽汽逆止阀、供热快关阀、供热蝶阀。10.2甩负荷时联关热网加热器进汽电动截止阀、供热抽汽逆止阀、供热快关阀。关闭供热蝶阀至全关位置持
本文标题:供热系统调试方案
链接地址:https://www.777doc.com/doc-4487612 .html