您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 商业计划书 > 富士通DX60-80安装手册正式
1ETERNUSETERNUSETERNUSETERNUSDX60/80DX60/80DX60/80DX60/80安装与维护手册2009-1-121.DX60和DX80介绍................................................................................................................21.1DX60外观:.....................................................................................................................21.2DX80外观..........................................................................................................................21.3ACOutlet......................................................................................................................31.4技术规格和电源规格........................................................................................................31.5电源确认............................................................................................................................42.ETERNUSDX60/80安装.......................................................................................................52.1安装前准备工作.................................................................................................................52.2存储上架............................................................................................................................62.2存储挡板的拆卸和安装....................................................................................................82.3硬盘安装打开硬盘锁定杆后平行插入存储槽位内。..........................................102.4ACOutlet上架...............................................................................................................102.5线缆连接..........................................................................................................................143.DX60/DX80状态...................................................................................................................203.1面板介绍...........................................................................................................................203.2控制柜去掉面板后的操作:.........................................................................................223.3控制柜和磁盘硬盘槽位:..............................................................................................223.4控制柜后视图:.............................................................................................................233.6Web管理方式..................................................................................................................233.7系统状态检查.................................................................................................................274.RAID配置和主机联调(RAID介绍参考相关资料).........................................................304.1创建RAID组....................................................................................................................304.2创建卷..............................................................................................................................313.日常维护..................................................................................................................................35注意事项.........................................................................................................................................3721.1.1.1.DX60DX60DX60DX60和和和和DX80DX80DX80DX80介绍介绍介绍介绍1.11.11.11.1DXDXDXDX60606060外观:DX60基本配置为一个控制柜(包括两个控制器),最多可以扩容一个磁盘柜。(控制柜:有能与主机连接的HBA的柜子为控制柜。)1.21.21.21.2DX80DX80DX80DX80外观DX80基本配置为一个控制柜(包括两个控制器),最多可以扩容9个磁盘柜。1.31.31.31.3ACACACACOutletOutletOutletOutlet外观分为两种:1U和2U。根据到货情况不同1U:1U:1U:1U:2U2U2U2U:31.41.41.41.4技术规格和电源规格技术规格:物理规格:支持RAID级别:41.51.51.51.5电源确认设备电源线规格长度功率DX60/DX804米ACOutlet(1U)4米ACOutlet(2U)4米2.2.2.2.ETERNUSETERNUSETERNUSETERNUSDX60/80DX60/80DX60/80DX60/80安装安装安装安装2.12.12.12.1安装前准备工作1.1.1.1.工具的准备请在设备安装前,准备好以下工具。2.2.2.2.FSTFSTFSTFST(CE(CE(CE(CETerminal)Terminal)Terminal)Terminal)请准备好控制终端或笔记本FST以便访问存储设备。3.3.3.3.交叉线5需要准备交叉线一条用于FST对存储设备的访问配置。4.4.4.4.设备上机架工具由于存储设备都需要安装在机架上,请准备好螺丝刀等上机架常用工具。5.5.5.5.设备开箱和外观检查在设备拆开包装后,进行以下的外观检查:去除设备上的塑料外罩,检查下列各项:表面是否损坏或比较脏;设备上的螺丝是否松动;在设备接头上是否有损坏;设备接头上是否松动;设备上的开关是否正常。检查设备包装中是否有钥匙,请妥善保存。如果发现外观损坏,请联系工程负责人员6.6.6.6.检查设备部件和附件在设备拆开包装后,请按照清单检查部件和附件是否齐全。7.7.7.7.检查设备输入电源存储设备输入电源如下:M100电压:AC200V-AC240VM200电压:AC200V-AC240V请用万用表检查设备输入电源是否接地,所需电压是否满足要求。2.22.22.22.2存储上架上架规则:6DX60/DX80的宽度和深度参见上面的规格参数,导轨有一定的幅度可以前后调整。1)存储导轨安装位置:DX系列控制柜和磁盘柜高度相同都为2U,导轨需要安装1U的位置,螺丝安装在机柜1U位置最上和最下位置,中间的孔需要安装卡子用来固定存储柜。2)固定存储导轨:[左侧]DX控制器或磁盘柜[右侧]M5螺丝第一个M5螺丝第一个M5螺丝M5螺丝柜子的底部存储柜安装位置DX80满配共10个柜子DX60满配只能增加一个磁盘柜173)存储上架安装导轨的时候中间空的那个孔需要安装卡子就是为“固定螺丝”用的。8安装磁盘扩展的时候要根据柜子上的数字ID,按照从下向上的顺序安装2.22.22.22.2存储挡板的拆卸和安装1)拆卸挡板拉住扣环并向外拉,就可以拆卸掉挡板。固定螺丝机柜后侧磁盘柜ID92)安装挡板注意Slot为两个卡槽,安装的时候要把挡板卡子插进卡槽内。向内推挡板知道卡住,安装完成。扣环102.32.32.32.3硬盘安装打开硬盘锁定杆后平行插入存储槽位内。锁定:注意锁定杆的钩子一定要挂住槽位的内壁。2.42.42.42.4ACACACACOutletOutletOutletOutlet上架(随机有配置的话,参看安装步骤,如没有配置可以忽略。)1)1UACOutlet导轨安装11ACOutlet上架前,需要安装固定螺丝的卡子,如下图:122)1UACOutlet上架4)1UACOutle前挡板安装5)2UACOutle导轨安装136)2UACOutlet上架7)2UACOutlet前挡板安装142.52.52.52.5线缆连接1)miniSAS数据线连接数据线连接分为两种,一种是单控制器模式和双控制模式。MiniSAS两头分为IN和OUT,请根据插头上的符号确认。菱形标记的是OUT接口圆形形标记的是IN接口控制柜只有OUT接口,下图为连接图:15磁盘柜包括OUT和IN接口,下图为连接图:单控制器线缆连接图:16双控制器miniSAS线缆连接图:17MiniSAS线缆拔出:182)电源线连接固定电源线:
本文标题:富士通DX60-80安装手册正式
链接地址:https://www.777doc.com/doc-4570910 .html