您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 工程监理 > 3#安全用电施工方案
1安全用电施工方案2目录一、工程概况.................................................................................................1二、设计内容和步骤.....................................................................................3三、用电管理.................................................................................................6四、电工.........................................................................................................7五、安全距离与外电防护.............................................................................7六、供电路线.................................................................................................8七、电缆线路.................................................................................................8八、配电柜(盘)、配电箱及开关箱.........................................................8九、电器装置的选择...................................................................................10十、使用与维护...........................................................................................10十一、照明....................................................................................................11十二、接地与防雷.......................................................................................12十三、防雷...............................................................................................123一、工程概况1、****工程位于盐平路,由****兴建,设计单位为***,施工单位为****。本工程为五层框架结构,建筑面积约40326平方米。工程施工场地已完成平整,甲方提供施工单位用水、用电的接驳点各一个,均设于现场边缘。并要求通往施工范围的道路可通行各种施工车辆,供施工设备及材料进场。2、施工现场用电量统计表如下(所有设备用电功率为KW)序号机具名称规格型号单位数量使用动力(KW/台)1塔吊QT80A台155.52潜水泵台101.13卷扬机JK1.5t台147.54锯木机台1535插入式振动机ZN50支121.16平板式振动机ZF150-50台61.17砂浆搅拌机ROOL台1238钢筋弯曲机台239钢筋切割机台2310电弧焊机台61311电渣压力焊机台23512砂轮切割机台2313洗车设备套2214照明台10l二、设计内容和步骤1、现场勘察及初步设计1)施工现场范围内上、下水管道及各种埋地线路径已清除,施工现场已通水电,现场内无一、二级负荷。施工现场由供电部门设一供电总箱内有计量设备。本设计只负责总箱以下的线路、电气开关的选择。42)根据施工现场用电设备布置情况,在场内沿围墙架设电缆,LFG至分配电箱,再由分配电箱引至各用电设备的开关箱。3)根据《施工现场临时用电安全技术规范》JGJ46-88规定,本供电系统采用TN-S(三相五线制)供电,设置二个回路。2、确定计算负荷(第一回路)1)钢筋机械组Kx=0.7tgψ=1.08cosψ=0.68Pe1=3×2+2×3+2×3+2×7.5=33kwPjs1=Kx×Pe1=0.7×33=23.10kw,Qjs1=Pjs1×tg=23.10×1.08=24.95Kwar2)井架组Kx=0.7tgψ=1.02cosψ=0.7Pe2=7.5×6=45kwPjs2=Kx×Pe2=0.7×45=31.5kw,Qjs1=Pjs2×tgψ=31.5×1.02=32.13Kwar3)塔吊组Kx=0.7tgψ=1.02cosψ=0.7Pe3=55.5kwPjs1=Kx×Pe3=0.7×55.5=38.85kw,Qjs3=Pjs3×tgψ=38.85×1.02=39.63Kwar4)电焊组Kx=0.45tgψ=1.98cosψ=0.45○1将Jc=50%统一换算到Jc=100%时额定容量Pe4=√Jc/Jc100×Pn=√0.5×13=9.19kw○2计算负荷Pjs5=Kx×Pe5=0.45×9.19=4.14kw,Qjs5=Pjs5×tgψ=4.14×1.98=8.20Kwar5)锯木组Kx=0.7tgψ=0.88cosψ=0.75Pe5=3×8=24kwPjs5=Kx×Pe5=0.7×24=16.8kw,Qjs5=Pjs5×tgψ=16.8×0.88=14.78Kwar6)砂浆机组Kx=0.7tgψ=1.08cosψ=0.68Pe6=3×6=18kwPjs6=Kx×Pe6=0.7×18=12.6kw,Qjs6=Pjs6×tgψ=12.6×1.08=13.61Kwar7)振动棒组Kx=0.7tgψ=1.02cosψ=0.7Pe6=1.1×12=13.2kwPjs6=Kx×Pe6=0.7×13.2=9.24kw,Qjs6=Pjs6×tgψ=9.24×1.02=9.42Kwar56)总的计算负荷计算、干线同期系数取Kx=0.9总的有用功率Pjs=Kx×(Pjs1+Pjs2+``````+Pjsn)=0.9×(23.10+31.5+38.85+4.14+16.8+12.6+9.24)=122.6kw总的无用功率Qjs=Kx×(Qjs1+Qjs2+``````+Qjsn)=0.9×(24.95+32.13+39.63+8.2+14.78+13.61+9.42)=128.5Kwar总的视在功率Sjs=√Pjs2+Qjs2=√122.62+128.52=177.6KWA总的计算电流Jjs=Sjs/√3Ve=269A选用90mm2铜芯塑料线,其允许持续电流270A269A3、确定计算负荷(第二回路)1)井架组Kx=0.7tgψ=1.02cosψ=0.7Pe1=7.5×6=45kwPjs1=Kx×Pe2=0.7×45=31.5kw,Qjs1=Pjs2×tgψ=31.5×1.02=32.13Kwar2)电焊组Kx=0.45tgψ=1.98cosψ=0.45○1将Jc=50%统一换算到Jc=100%时额定容量Pe2=√Jc/Jc100×Pn=√0.5×35=24.75kw○2计算负荷Pjs3=Kx×Pe3=0.45×24.75=11.14kw,Qjs2=Pjs3×tgψ=11.14×1.98=22.06Kwar3)锯木组Kx=0.7tgψ=0.88cosψ=0.75Pe4=3×7=21kwPjs4=Kx×Pe4=0.7×21=14.7kw,Qjs4=Pjs4×tgψ=14.7×0.88=12.94Kwar4)砂浆机组Kx=0.7tgψ=1.08cosψ=0.68Pe5=3×6=18kwPjs5=Kx×Pe5=0.7×18=12.6kw,Qjs5=Pjs5×tgψ=12.6×1.08=13.61Kwar5)振动棒组Kx=0.7tgψ=1.02cosψ=0.7Pe6=1.1×6=6.6kwPjs6=Kx×Pe6=0.7×6.6=4.62kw,Qjs6=Pjs6×tgψ=4.62×1.02=4.71Kwar66)总的计算负荷计算、干线同期系数取Kx=0.9总的有用功率Pjs=Kx×(Pjs1+Pjs2+``````+Pjsn)=0.9×(31.5+24.75+14.7+12.6+4.62)=88.17kw总的无用功率Qjs=Kx×(Qjs1+Qjs2+``````+Qjsn)=0.9×(32.13+22.06+12.94+13.61+4.71)=85.45Kwar总的视在功率Sjs=√Pjs2+Qjs2=√288.172+85.452=122.78KWA总的计算电流Jjs=Sjs/√3Ve=122.78/√3×0.35=201A选用70mm2铜芯塑料线,其允许持续电流210A201A。另外生活用电单独设一个回路,选用25mm2铜芯塑料线,宿舍区供电采用36V电压供电。三、用电管理⒈临时用电必须按“《施工现场临时用电安全技术规范》JGJ46-88”编制用电施工组织设计制定安全用电技术措施和电气防火措施。⒉临时用电工程图纸必须单独由电气工程技术人员绘制,经技术负责人审批后作为临时施工的依据。⒊临时用电施工组织设计的内容和步骤:⑴现场勘探,确定电源进线总配电箱(柜),分配电箱的位置及线路走向。⑵进行负荷计算,选择导线截面和电器的类型、规格。⑶绘制电气平面图,立面图和接线系统图。⑷制定安全用电技术措施和电气防火措施。⒋施工现场临时用电安全技术档案:⑴临时用电施工组织设计及修改施工组织设计的全部资料。⑵技术交底资料。⑶临时用电工程检查验收表。⑷接地电阻测定记录。⑸定期检(复)查表(工地每月,公司每季进行一次)。⑹电工维修工作记录。7⒌安装、维修或拆除临时用电工程,必须由电工完成,电工等级应同工程的难易程度和技术复杂性相适应。四、电工⒈电工必须经过专业及安全技术培训,经(地)市劳动部门考试合格发给操作证,方准独立操作。⒉电工应掌握用电安全基本知识和所有设备性能。⒊上岗前按规定穿戴好个人防护用品。⒋停用设备应拉闸断电,锁好开关箱。⒌负责保护用电设备的负荷线,保护零线(重复接地)和开关箱。⒍移动用电设备必须切断电源,在一般情况下不许带电作业,带电作业要设监护人。⒎按规定定期(工地每月、公司每季)对用电线路进行检查,发现问题及时处理,并做好检查和维修记录。⒏应懂得触电急救常识和电器灭火常识。五、安全距离与外电防护外电线路:指施工现场临时用电线路以外的任何电力线路。⒈不得往高、低压线路下方施工、搭设临时设施或堆放物件、架具、材料及其他杂物。⒉安全距离:⑴在建工程(包括脚手架)的外侧与架空线路之间的最小安全距离1kv不小于4m,1~10kv不小于6m,35~110kv不小于8m。架空导线最大弧垂与施工现场地面最小距离≥4.0m与机动车道≥6.0m。⑵起重臂或被吊物边缘与10kV的架空线路水平距离≥2m。⑶机动车道与外电架空线路交叉的最小距离1kv以下为6m,10kv以下为7m。⒊外电防护:⑴达不到安全距离要求,必须采取防护措施,增设屏障、遮栏、围栏或保护网,并悬挂醒目的警告标志牌。⑵带电体至遮栏的安全距离10kv应大于95cm,35kv应大于115cm.⑶带电体至栅栏(封闭)的安全距离10kv应大于30cm,35kv应大于50cm。⑷在架设防护设施时,应有电气技术人员或专职安全员监护。8⑸无法防护时必须采取停电,迁移线路或更改工程位置,否则不准施工。六、供电路线架空线路必须架设在专用电杆上,严禁架设在树木上或脚手架上等不稳固的地方。⒈架空线路最少截面:为满足机械强度要求,铝线≥1
本文标题:3#安全用电施工方案
链接地址:https://www.777doc.com/doc-4831294 .html