30020000.65%0.20%50桩直径(mm)桩截面面积(mm2)1号纵筋根数1号纵筋直径(mm)2号纵筋根数2号纵筋直径(mm)纵筋面积(mm2)配筋表达60028274381601616088φ167003848451016016201110φ168005026541018018254510φ189006361721218018305412φ1810007853981418018356314φ1811009503311618018407216φ18120011309721818018458018φ18130013273222018018508920φ181400153937910201018568610φ20+10φ18150017671442418018610724φ18160020106182418018610724φ18170022697992418018610724φ18180025446882618018661626φ18190028352852618018661626φ18200031415902818016712528φ18210034636033018018763430φ18220038013243218018814332φ18230041547533020018942530φ202400452389032200181005332φ202500490873434200181068134φ202600530928736200201131036φ202700572554838200201193838φ202800615751642200201319542φ20桩身配筋选用表(非广东、浙江地区)规范推荐的构造要求(“可”条文)桩直径(mm)截面配筋率纵筋保护层(mm)2)高边坡建筑;多层建筑桩身构造配筋选用表(一)建议适用范围:1)高度大于80m的高层建筑,且承受水平力较大(如7度、8度区或强台风地区w65)、且地下室外围土地约束及桩侧土体很差;3)较高的超高层(但基坑较深、且土质较好的超高层可选用表二);2900660519344200201382344φ2030007068578222222201527422φ22+22φ20备注:1)桩身直径600~700时,箍筋直径取φ6;桩身直径800~1500时,箍筋直径取φ8,桩身直径大于1500时取φ10。对于桩侧土体较好、理论上基本不承受水平力、且不考虑钢筋受压的桩,箍筋间距@250;2)桩顶箍筋加密长度2~3m,间距@100。对于受水平荷载较大、承受水平地震作用、以及计算计入受压钢筋作用的桩,加密长度为5倍桩身直径;3)加劲箍直径可参照浙江规定选取。桩身直径1600~2500时,建议取φ18;桩身直径2600~3000时,建议取φ20。但对于井下绑扎钢筋的人工挖孔桩,加劲箍最大不宜超过φ16,不应超过φ18。实际配筋率最小配筋率配筋率是否满足要求纵筋处圆周长(mm)纵筋中心距(mm)0.57%0.57%不满足要求15211900.52%0.54%不满足要求18351830.51%0.52%不满足要求21432140.48%0.49%不满足要求24572050.45%0.46%不满足要求27711980.43%0.44%不满足要求30851930.41%0.41%不满足要求33991890.38%0.39%不满足要求37131860.37%0.36%满足要求40212010.35%0.33%满足要求43421810.30%0.31%不满足要求46561940.27%0.28%不满足要求49702070.26%0.25%满足要求52842030.23%0.23%满足要求55982150.23%0.20%满足要求59122110.22%0.20%满足要求62272080.21%0.20%满足要求65412040.23%0.20%满足要求68492280.22%0.20%满足要求71632240.22%0.20%满足要求74772200.21%0.20%满足要求77912160.21%0.20%满足要求81052130.21%0.20%满足要求8419200桩身配筋选用表(非广东、浙江地区)2)高边坡建筑;多层建筑桩身构造配筋选用表(一)建议适用范围:1)高度大于80m的高层建筑,且承受水平力较大(如7度、8度区或强台风地区w65)、且地下室外围土地约束及桩侧土体很差;3)较高的超高层(但基坑较深、且土质较好的超高层可选用表二);0.21%0.20%满足要求87341980.22%0.20%满足要求90412051)桩身直径600~700时,箍筋直径取φ6;桩身直径800~1500时,箍筋直径取φ8,桩身直径大于1500时取φ10。对于桩侧土体较好、理论上基本不承受水平力、且不考虑钢筋受压的桩,箍筋间距@250;2)桩顶箍筋加密长度2~3m,间距@100。对于受水平荷载较大、承受水平地震作用、以及计算计入受压钢筋作用的桩,加密长度为5倍桩身直径;3)加劲箍直径可参照浙江规定选取。桩身直径1600~2500时,建议取φ18;桩身直径2600~3000时,建议取φ20。但对于井下绑扎钢筋的人工挖孔桩,加劲箍最大不宜超过φ16,不应超过φ18。30020000.65%0.20%50桩直径(mm)桩截面面积(mm2)1号纵筋根数1号纵筋直径(mm)2号纵筋根数2号纵筋直径(mm)纵筋面积(mm2)配筋表达实际配筋率最小配筋率配筋率是否满足要求纵筋处圆周长(mm)纵筋中心距(mm)60028274381601616088φ160.57%0.57%不满足要求15211907003848451016016201110φ160.52%0.54%不满足要求18351838005026541018018254510φ180.51%0.52%不满足要求21432149006361721218018305412φ180.48%0.49%不满足要求245720510007853981418018356314φ180.45%0.46%不满足要求277119811009503311618018407216φ180.43%0.44%不满足要求30851931200113097282081845498φ20+8φ180.40%0.41%不满足要求3393212130013273222018018508920φ180.38%0.39%不满足要求37131861400153937910201018568610φ20+10φ180.37%0.36%满足要求40212011500176714410201018568610φ20+10φ180.32%0.33%不满足要求4335217160020106182418018610724φ180.30%0.31%不满足要求4656194170022697992418018610724φ180.27%0.28%不满足要求4970207180025446882618018661626φ180.26%0.25%满足要求5284203190028352852618018661626φ180.23%0.23%满足要求5598215200031415902818016712528φ180.23%0.20%满足要求5912211210034636033018018763430φ180.22%0.20%满足要求6227208220038013243218018814332φ180.21%0.20%满足要求6541204230041547533020018942530φ200.23%0.20%满足要求68492282400452389032200181005332φ200.22%0.20%满足要求71632242500490873434200181068134φ200.22%0.20%满足要求74772202600530928736200201131036φ200.21%0.20%满足要求77912162700572554838200201193838φ200.21%0.20%满足要求81052132800615751642200201319542φ200.21%0.20%满足要求84192002900660519344200201382344φ200.21%0.20%满足要求873419830007068578222222201527422φ22+22φ200.22%0.20%满足要求9041205备注:1)对一般高层建筑,特别是多层结构,实际配筋率略小于最小配筋率时,比如差1个percent(但不小于0.2%),一般可认为满足要求;2)非常重要部位、或者较高的超高层建筑,地下室层数较少或者桩侧土体很差时,实际配筋率不应小于最小配筋率。3)桩身直径600~700时,箍筋直径取φ6;桩身直径800~1500时,箍筋直径取φ8,桩身直径大于1500时取φ10。对于桩侧土体较好、理论上基本不承受水平力、且不考虑钢筋受压的桩,箍筋间距@250;4)桩顶箍筋加密长度2~3m,间距@100。对于受水平荷载较大、承受水平地震作用、以及计算计入受压钢筋作用的桩,加密长度为5倍桩身直径;5)加劲箍直径可参照浙江规定选取。桩身直径1600~2500时,建议取φ18;桩身直径2600~3000时,建议取φ20。但对于井下绑扎钢筋的人工挖孔桩,加劲箍最大不宜超过φ16,不应超过φ18。二、桩身配筋构造要求计算表国家桩基规范要求桩身最小配筋率计算表格一、请输入构造要求桩直径(mm)截面配筋率纵筋保护层(mm)30020000.65%0.20%50一、高层建筑桩基安全等级为一级(A1)时桩身配筋构造要求计算表桩直径(mm)桩截面面积(mm2)纵筋根数纵筋直径(mm)纵筋面积(mm2)配筋表达实际配筋率60028274381820368φ180.72%7003848451018254510φ180.66%8005026541218305412φ180.61%9006361721220377012φ200.59%10007853981420439814φ200.56%11009503311620502716φ200.53%120011309721820565518φ200.50%130013273222020628320φ200.47%140015393792220691122φ200.45%150017671442420754024φ200.43%原图集注:桩顶5D范围内箍筋加密,间距为150mm。二、高层建筑桩基安全等级为二级(A2)时桩身配筋构造要求计算表桩直径(mm)桩截面面积(mm2)纵筋根数纵筋直径(mm)纵筋面积(mm2)配筋表达实际配筋率60028274381616088φ160.57%7003848451016201110φ160.52%8005026541216241312φ160.48%9006361721218305412φ180.48%10007853981418356314φ180.45%11009503311618407216φ180.43%120011309721818458018φ180.41%130013273222018508920φ180.38%140015393792218559822φ180.36%150017671442418610724φ180.35%原图集注:桩顶5D范围内箍筋加密,间距为150mm。浙江省图集-钻孔灌注桩配筋表请输入构造要求桩直径(mm)截面配筋率纵筋保护层(mm)备注:1)本表格按照浙江省标准图集《2004浙G23钻孔灌注桩》第11页“配筋表(一)”编制;该图集解释为本表适应于高层建筑。2)本表采用的原图集中“安全等级”,应为对应旧的桩基规范,现应理解为对应甲级、乙级基础设计等级。三、多层建筑桩基安全等级为一级(B1)时桩身配筋构造要求计算表桩直径(mm)桩截面面积(mm2)纵筋根数纵筋直径(mm)纵筋面积(mm2)配筋表
本文标题:灌注桩桩身构造配筋计算原始表格-按国家规范
链接地址:https://www.777doc.com/doc-5080768 .html