您好,欢迎访问三七文档
当前位置:首页 > 办公文档 > 规章制度 > HoneywellSensepointXCD基本操作培训-共40页PPT资料
基础培训SensepointXCD2TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD概述端子底板模块天气保护罩传感器固定环插入式智能传感器防爆外壳M20(x2)或¾”NPT(x2)电缆进线接口罩体显示器模块不锈钢堵头标定用磁棒集成安装底板认证铭牌3TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD机械参数•材质-LM25型喷塑铝合金适用于一般工业应用场合-316不锈钢喷塑材质适用于海上平台及其他更恶劣的环境食品和饮料行业•防爆认证-ATEX,IECEx,UL,Ex(中国防爆认证)•安装-4个集成安装孔-适用于直径M8的螺栓-可选立柱安装和管道安装附件•进线接口-2xM20(ATEX/IECEx版本)-2x¾”NPT(UL/CSA版本)-1个标配不锈钢堵头•外观尺寸:图中单位是mm4TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCDRTD机械参数*AvailablewithphaseBreleaseM20HolesforATEXandIECExVersions.5TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD选配附件•立柱式安装附件-探测器本体必须固定在水平或垂直立柱上-适用于Ø40.0-80.0mm的立柱•风道安装附件(仅适用于CO,H2和H2S气体)-传感器置于风道内,而变送器置于风道外-适用于方形或矩形的风道风道壁厚至少1mm-标定气体接口仅适用于bumptest标定时还是推荐使用标定帽适用于内径6mm的软管6TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD附件•遮阳/防雨罩:-保护XCD过分暴露在过热或干燥的环境里。-增强XCD在热带地区的耐受性-与XCD集成安装底板可以契合•带进气口的标准天气保护罩-户外适用于推荐使用-进气口仅适用于bumpTest适用于内径6mm的软管7TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD附件•标定磁棒-用于XCD的标定和参数设置•标定帽-标定探测器用-适用于内径6mm的软管对于红外传感器,毒气和氧气传感器,流量为500ml/分钟。1Ltr/minforcatalytic对于催化燃烧传感器,流量为1L/分钟。•集气罩(适用于CO和H2)-帮助探测器更好的捕捉和检测轻质气体-不适用于墙面安装和顶部安装8TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD安装方式CeilingMountedDuctMountedWallMountedPipeMountedSamplingSystem9TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD接线XCD端子底板模块内置接地点123456789101112131415RearViewof‘Puck’注意:端子块是插拔式的,拆卸前请先把导线取下10TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCDRTD接线11TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCDRTD远程传感器SensepointXCD远程氨气传感器是一种专门为SensepointXCDRTD变送器设计的远程氨气传感器.它包含两个部件:1.XCD传感器腔2.插座式外罩传感器接口螺纹M25典型安装方式是使用Bartec盒(00780-A-0100)12TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD电气参数及接线示意图•信号输出-标准工业4-20mA信号可通过选择开关选择源电流或漏电流输出-信号超量程22mA-仪表故障≥0.01.0mA-仪表抑制(可选)可燃气/毒气:2mA或4mA(氧气2mA或17.4mA)•工作电压-16至32Vdc(标准值24Vdc)•功耗(max)-催化燃烧:4.9W,电化学:3.7W,红外:3.7W•接线-合适的屏蔽电缆和进线格兰头-3芯屏蔽电缆最好是90%覆盖率-线径0.5mm2到2.5mm2(Approx.20to14AWG)请确保输送到探测器侧的电压达到至少16Vdc源电流接线方式示意图漏电流接线方式示意图特别注意:屏蔽层一定要单点接地13TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD电缆长度计算电缆参数最长电缆长度Cablesize(crosssectionalarea)CableresistanceCatalyticECCIRΩ/kmΩ/miMetresFeetMetresFeetMetresFeet0.5mm2(20AWG*)36.859.23561167478156842013791.0mm2(17AWG*)19.531.46712201902295679325991.5mm2(16AWG*)12.720.41031338713844549121740002.0mm2(14AWG*)10.116.31296423917415694153150062.5mm2(13AWG*)812.9163653562197719419326326*Nearestequivalent以下参数是根据控制器和探测器之间的单程回路电压降4V来计算的最长电缆长度。电缆长度与电缆的直径有关。详细的计算方法和更多的参数参见XCD用户后侧14TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD各种各样的传感器*ContactHAforAvailabilityof%Vol.IRFlammable1to8*20.0to100.0%LEL100%LEL10%LEL50%LELMethane20.0to100.0%LEL100%LEL10%LEL50%LELMethane20to100%Vol*100%Vol10%Vol50%VolCarbonDioxide2%Volonly2%Voln/a1%VolHydrogenSulfide10.0to100.0ppm50.0ppm0.1ppm10ppmCarbonMonoxide100to1,000ppm300ppm10ppm100ppmHydrogen1,000ppmonly1,000ppmn/a500ppmO2Oxygen25.0%Volonly25.0%Voln/a20.9%Vol(Fixed)20.9%VolSensorFamilySensepointXCDSensorFamilies,GasesandRangesStepsSelectableCalGasRangeDefaultCalPointGasmVEC30to70%ofselectedfullscalerangeElectrochemicalSensorsInfraredSensorsCatalyticBeadSensorsUserSelectableFullScaleRangeDefaultRange15TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD面板显示•三色LCD背光•易识别状态灯,且显示及时•远距离同样清晰显示独特的状态显示和友好的菜单操作界面测量单位UP磁性开关报警图标抑制图标报警/故障图标测试通过图标磁棒激活图标MENU/ENTER磁性开关满量程条线图气体类型气体读数DOWN磁性开关标定图标16TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD操作面板•工作状态图标-:测试通过图标-:故障+错误代码-:抑制模式-:标定模式•气体读数-数字-柱状图-绿色背光•气体配置-气体类型-测量量程-测量单位•磁性开关-菜单/确认键-增加键-下降键柱状图(安比例显示读数)气度读数测量单位气体类型测试图标满量程17TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD状态输出SystemStatusRelayStatusDisplayCurrentOutputA1A2FaultBackLightFault:CircuitorsensorerrorF-XXfaultnumberwithfaulticonblinking0-1.0mASystemFaultN/A0-0.15mAYellow,flashingNote:Intheeventofprocessorfailurethewatchdogwillautomaticallyresetthesystemforrecovery.WarningW-XXwarningnumberwithfaulticonblinkingDependentonsystemstatusGreenSteadyNormal0.0Gasconcentration4-20mAGreenSteadyAlarm1Gasconcentration.1stalarmiconblinking4-20mARed,flashingAlarm2Gasconcentration.2ndalarmiconblinking4-20mA1Red,flashingOver-rangeFullscaleiconandreadingblinking22mA2Red,flashingInhibitInhibiticondependentonMenucommand.Ifanyrelayissettoinhibitrelay,theninhibitrelaywillbeactivated.2or4mAdependingonconfiguration.Note:2or17.4mAforOxygenversionGreenSteadyNote:1.ForOxygen,A1relaywillnotbeactivatedbecauseAL1isconfiguredtoactivateabove23.5%Vol(inRisingAlarmconfiguration).2.ForOxygen,A2relaywillnotbeactivatedbecauseAL2isconfiguredtoactivatebelow19.5%Vol(inFallingAlarmconfiguration).18TrainingPresentationSensepointXCDrev1HONEYWELL-CONFIDENTIALSensepointXCD预故障代码(WarningCodes)故障代码故障描述修正措施W-01标定超期重新表订探测器取消预故障W-02探测器内温度超标当探测器内温度回复到正常区间后,点击‘’W-03报警设定值需要确认部分报警设定值超过用户量程,重新设定报警值W-04
本文标题:HoneywellSensepointXCD基本操作培训-共40页PPT资料
链接地址:https://www.777doc.com/doc-5364622 .html