您好,欢迎访问三七文档
当前位置:首页 > 临时分类 > 无人值守变电站及监控中心技术导则
ICS29.240国家电网公司企业标准Q/GDW231—2008无人值守变电站及监控中心技术导则Thetechnicalguidelineofunattendedsubstationandthesupervisoryandcontrolcenter2009-06-22发布2009-06-22实施国家电网公司发布Q/GDWQ/GDW231—2008I目次前言···································································································································································II1范围·····························································································································································12规范性引用文件··········································································································································13定义和术语··················································································································································14无人值守变电站基本要求··························································································································25无人值守变电站的技术要求······················································································································26监控中心的基本要求··································································································································57监控中心的技术要求··································································································································5附录A(资料性附录)····································································································································8附录B(资料性附录)··································································································································10编制说明·························································································································································13Q/GDW231—2008II前言随着国民经济的快速发展,电网规模迅速扩大,新建变电站尤其是220kV及以上电压等级的新建变电站大量投运。为适应变电站无人值守发展形势,提高变电站技术水平和运行管理水平,各地区陆续开展和实施了无人值守变电站及监控中心的建设和改造。为贯彻国家电网公司“两型一化”战略,规范无人值守变电站及监控中心的建设和技术改造,提高运行维护水平,保障无人值守变电站安全、可靠运行,促进无人值守变电站及监控中心实施过程的规范化和资源节约,在总结无人值守变电站及监控中心设计、建设、调试、运行维护和改造经验以及相关专业领域研究成果基础上,制定本标准。本标准由国家电网公司科技部归口。本标准由国家电网公司生产技术部提出并负责解释。本标准主要起草单位:华东电网有限公司,华东电力试验研究院有限公司本标准参与起草单位:上海市电力公司,浙江省电力公司,江苏省电力公司,天津市电力公司,河南省电力公司,北京市电力公司,辽宁省电力公司,河北省电力公司本标准主要起草人:杨国庆杨凌辉周健陆文宇李宝兴冒烨颖傅晨钊赵海生高凯付艳华王锐李胜川马峰贾志辉Q/GDW231—20081无人值守变电站及监控中心技术导则1范围本技术导则规定了无人值守变电站及监控中心设计、施工、运行应遵循的技术原则和技术要求,适用于国家电网公司系统内的无人值守变电站及配套监控中心。本技术导则主要针对无人值守变电站及监控中心特点,未述及的技术要求仍然参照常规变电站的规程规范执行。本技术导则主要适用于220kV及以上无人值守变电站及监控中心,220kV以下的无人值守变电站参照执行。2规范性引用文件下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。GB/T13729—2002远动终端设备GB/T14285—2006继电保护和安全自动装置技术规程GB50054—1995中华人民共和国国家标准低压配电设计规范GB50229—2006火力发电厂与变电所设计防火规范DL5003—2005电力系统调度自动化设计技术规程DL/T5103—199935~110kV无人值班变电所设计规程DL/T5218—2005220kV~500kV变电所设计技术规程DL/T5149—2001220kV~550kV变电所计算机监控系统设计技术规程DL/T5155—2005220kV~500kV变电所所用电设计技术规程DL/T860变电站网络通信和系统DL/T634.5101远动设备及系统:第5-101部分传输规约基本远动任务配套标准国家经贸委第30号令电网和电厂计算机监控系统及调度数据网络安全防护规定电监会第5号令电力二次系统安全防护规定Q/GDW161-2007线路保护及辅助装置标准化设计规范Q/GDW175-2008变压器、高压并联电抗器和母线保护及辅助装置标准化设计规范国家电网生技(2005)400号十八项电网重大反事故措施国家电网安监(2007)699号反事故斗争25条重点措施国家电网安监(2006)904号国家电网公司防止电气误操作安全管理规定国家电网生(2006)512号变电站管理规范国家电网调继(2005)222号国家电网公司十八项电网重大反事故措施(试行)继电保护专业重点实施要求国家电网公司变电站安全技术防范配置指导意见(试行)3定义和术语3.1无人值守变电站unattendedsubstation在监控中心(集控站)的管辖范围内,能够向监控中心(集控站)上传相关设备及其运行情况的遥测、遥信、遥视等信息,具备接收并执行监控中心(集控站)下发的遥控、遥调指令等功能。站内不设Q/GDW231—20082置固定运行维护值班岗位,由监控中心(集控站)负责完成运行工作的变电站。3.2监控中心supervisoryandcontrolcenter具备对所辖各集控站或无人值守变电站相关设备及其运行情况进行远方遥控、遥测、遥信、遥调、遥视等功能的监测控制中心,其管辖的范围可按电压等级或区域进行划分。也可称为集控中心。3.3集控站gather-controlstation具备对所辖各变电站相关设备及其运行情况进行远方遥控、遥测、遥信、遥调、遥视等功能的中心变电站,可设在与所辖变电站相关的某一变电站,其管辖的范围可按电压等级或区域进行划分。3.4程序化控制programcontrol利用计算机系统等自动化设备,根据编制的程序或预设的条件所进行的控制行为。4无人值守变电站基本要求无人值守变电站的技术和设备选择应遵循“安全、高效、环保”原则,优先采用技术成熟、结构简单、自动化程度高、少维护的高可靠性产品。无人值守变电站应保留必要的基本生活设施,具备完善的防火、防盗等措施。站内建筑应满足安全工器具等的存放需要。应适当考虑变电站检修、保电、防灾等特殊需要。在保证电网可靠运行的基础上,应适当简化接线方式。同一地区在同一电压等级上宜采用统一的接线方式和设备配置原则。无人值守变电站的继电保护及安全自动装置应选用性能稳定、质量可靠的微机型产品,满足继电保护反措、设备标准化企业标准和有关规程规定要求,并应具备信息远传功能。无人值守变电站的自动化系统,应采用变电站计算机监控系统。变电站的信息采集应满足无人值守的运行要求。无人值守变电站的通信配置应能支撑无人值守站各分系统对通信的需要。原则上至调度和监控中心的通信配置应满足双通道的要求。无人值守变电站的交直流电源设备应根据无人值守站的实际地理和交通条件考虑适当提高配置,应具备远方监视和控制功能。无人值守变电站应配置相应的视频安防、消防、环境监测等系统,并应能够实现远方监视和控制。5无人值守变电站的技术要求无人值守变电站的技术要求首先需要满足常规变电站标准规范的规定,各项技术指标应不低于相关标准中的规定,无人值守变电站需着重提出的技术要求如下:5.1建筑无人值守变电站在保留必要的基本生活设施前提下,可适当简化原常规变电站内的为人服务设施。变电站内建筑面积和功能设置应适当考虑变电站检修等特殊情况的需要。无人值守变电站监控中心、操作队所在变电站应考虑适当增加建筑面积,满足生产和生活所需设施要求。无人值守变电站的建筑物一楼应少设门窗,对于必要的门窗,应考虑实体防护措施。5.2一次设备在保证电网可靠运行的基础上,应适当简化接线方式。所有一次设备必须安全可靠。应选用设计完善、工艺优良、运行业绩优异的产品。同一地区在同一电压等级上宜采用统一的接线方式和设备配置原则。设备的外绝缘配置应以污区分布图为基础,并考虑环境污染变化因素。对需要加强防污措施的,应采用大爬距定型设备。无人值守变电站变压器在满足电网运行需要的情况下择优选取调压方式。500kV主变压器宜选用无励磁调压变压器。主变压器和站用变压器采用有载调压开关的应具备远方调节功能。主变压器冷却系统Q/GDW231—20083等应可靠性高,维修量少,具备自动控制功能。无人值守变电站的断路器、隔离开关、接地开关的主回路应接触良好,操动机构、储能机构、辅助接点应可靠,电动机回路等应故障率低。有条件的应优先选择气体绝缘组合电器(GIS)设备。无人值守变电站的断路器应具备远控和近控功能,隔离开关、接地开关宜具备手动和电动功能,有条件的应优先选择电动操作。电动操作应具备受控站就地、远方操作和监控中心远方操作功能,受控站操作和监控中心远方操作应能相互闭锁。断路器应选用无油化产品,真空断路器应选用本体和机构一体化产品。投切无功设备的断路器应选用无重燃及适合频繁操作的产品。隔离开关宜采用垂直或水平开启式(包括组合型式),操动机构宜采用电动操作。隔离
本文标题:无人值守变电站及监控中心技术导则
链接地址:https://www.777doc.com/doc-5482937 .html