您好,欢迎访问三七文档
石膏板吊顶施工方案XX工程公司年月日2目录1.主要编制依据........................................................42.工程概况............................................................42.1标准层卫生间:.................................................42.2地下室卫生间:.................................................42.3标准层走廊:...................................................42.4标准层会议室:.................................................52.5消防电梯厅、贵宾电梯厅:.......................................53.施工安排............................................................53.1主要机具投入...................................................53.2施工工期.......................................................54.施工准备............................................................64.1材料准备.......................................................64.1.1卫生间石膏板吊顶体系组成.......................................64.1.2走廊及其他房间石膏板吊顶体系组成...............................64.2材料进场要求...................................................74.2.1材料验收.......................................................74.2.2材料搬运.......................................................74.2.3材料码放及标志.................................................74.2.4注意事项.......................................................74.3技术准备.......................................................85.主要施工方法及技术措施..............................................95.1卫生间石膏板吊顶施工流程.......................................95.1.1隔墙测量放线...................................................95.1.2顶棚标高弹线...................................................95.1.3墙体顶棚钢骨架施工.............................................95.1.4墙体施工......................................................105.1.5边龙骨的安装..................................................105.1.6副龙骨安装....................................................1135.1.7顶棚内机电的安装..............................................115.1.8横撑龙骨安装..................................................125.1.9石膏板的安装..................................................125.1.10接缝处理......................................................125.1.11涂料施工......................................................135.2走廊及其它房间石膏板吊顶施工流程..............................135.2.1顶棚标高弹线..................................................135.2.2在地面上划龙骨分档线..........................................135.2.3按照弹线安装吊杆..............................................135.2.4边龙骨安装....................................................145.2.5主龙骨安装....................................................145.2.6次龙骨安装....................................................145.2.7横撑龙骨安装..................................................145.2.8开洞制作......................................................155.2.9管线安装......................................................155.2.10石膏板的安装..................................................165.2.11接缝处理......................................................165.2.12涂料施工......................................................166.质量保证措施.......................................................176.1主控项目......................................................176.2一般项目......................................................176.3质量控制标准及允许偏差........................................177.成品保护措施.......................................................188.其它应注意的事项...................................................187.1场地条件......................................................187.2应注意事项....................................................187.3安全文明施工保证措施..........................................1841.主要编制依据《建筑装饰装修工程质量验收规范》(GB50210-2001)《建筑工程施工质量验收统一标准》(GBJ50300-2001)《民用建筑工程室内环境污染控制规范》(GBJ50325-2001)《建设工程项目管理规范》(GBJ50326-2001)《北京****大厦施工组织设计》(CL4/A138/C/2002)《高级建筑装饰工程质量检验评定标准》(DBJ01-27-96)《北京市建筑工程施工现场安全管理标准》(DBJ01-62-2002)《建筑安装分项工程施工工艺规程》(DBJ01-26-96)北京****大厦装修深化图纸2.工程概况层高标准层H=3.96m,地下室HB4=4.80m,HB3=4.80m,HB2=6.00m.施工部位标准层卫生间、地下室卫生间、标准层走廊、标准层会议室、、消防电梯厅、贵宾电梯厅2.1标准层卫生间:由于建筑师设置卫生间与机电设备管井相邻,管井中分支出很多管道;且大量的机电设备从卫生间吊顶中穿过,机电设备下底面标高只有+2.400m。建筑师与机电协调后将卫生间吊顶完成面标高定为+2.300m。由于机电有尺寸很大的风管从吊顶内部穿过,采用常规吊杆体系支撑吊顶已无法实现,故只能用槽钢和角钢代替原常规吊杆体系。由于卫生间吊顶为非常规吊顶体系,根据其自身特点及实际情况,靠近管井一侧墙体及整个卫生间吊顶采用钢架体系。2.2地下室卫生间:地下室卫生间吊顶体系的吊杆采用内迫胀栓。其它工艺同常规石膏板吊顶体系。2.3标准层走廊:走廊及其它房间(卫生间除外)吊顶体系的吊杆采用内膨胀形式胀栓。5由于走廊纵向有尺寸很大的风管穿过吊顶,且风管位置并不在走廊的中间,故现场需要做增加吊杆或其它措施进行处理。2.4标准层会议室:标准层会议室吊顶体系的吊杆采用内迫胀栓。其它工艺同常规石膏板吊顶体系。会议室两侧设条形金属板,板内设条形风口。2.5消防电梯厅、贵宾电梯厅:消防电梯厅、贵宾电梯厅吊顶体系的吊杆采用内迫胀栓。其它工艺同常规石膏板吊顶体系。3.施工安排3.1主要机具投入机具计划投入表机具名称型号数量备注电锯4X2台用于切割石膏板无齿锯6X2台用于切割龙骨电动螺丝枪4X2把用于将螺丝打入石膏板铅锤、靠尺4X2把用于弹线、检查平整度等射钉枪4X2把3.2施工工期本工程施工时间拟于2004年8月开工,2005年3月结束。具体时间以项目经理部每月、每周、每日的施工计划为准。64.施工准备4.1材料准备4.1.1卫生间石膏板吊顶体系组成石膏板吊顶体系组成序号名称规格型号备注1槽钢80*432角钢50*53边龙骨DU20拉法基4副龙骨DF50拉法基5W型边龙骨W21*25铝合金6横撑龙骨DF50拉法基7卡件DCLIP50-50拉法基8挂件DCN50拉法基9副龙骨连接件DFC50拉法基10自攻螺丝25拉法基11石膏板12厚防潮纸面石膏板拉法基12吊杆Φ164.1.2走廊及其他房间石膏板吊顶体系组成石膏板吊顶体系组成序号名称规格型号备注1内迫胀栓吊杆Φ8、Φ10吊杆2m以上采用Φ102主龙骨DM38拉法基3边龙骨DU20拉法基4副龙骨DF50拉法基5横撑龙骨DF50拉法基76卡件DCLIP50-50拉法基7W型边龙骨W21*25铝合金8挂件DCN50拉法基9主龙骨连接件DMC38拉法基10副龙骨连接件DFC50拉法基11自攻螺丝25拉法基12石膏板12厚普通纸面石膏板拉法基4.2材料进场要求4.2.1材料验收材料运到指定地点后进行验收,核对材料出厂证明、品种、规格、数量。石膏板应干燥、平整、面纸完整无伤,受潮、弯曲变形、板中断裂、面纸起鼓等均不得使用;轻钢龙骨应平整、光滑、无锈蚀、无变形。4.2.2材料搬运材料搬
本文标题:石膏板吊顶施工方案
链接地址:https://www.777doc.com/doc-5840278 .html