您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > TCEC2262019直流配电网DCDC变换器试验方法
ICS29.240F20准T/CEC226—2019直流配电网DC/DC变换器试验方法TestmethodsforDC/DCconvertersofDCdistributiongrid2019-04-02发布2019-07-01实施中国电力企业联合会发布中国电力企业联合会标准直流配电网DC/DC变换器试验方法T/CEC226—2019*中国电力出版社出版、发行(北京市东城区北京站西街19号100005)北京九天鸿程印刷有限公司印刷*2019年8月第一版2019年8月北京第一次印刷880毫米×1230毫米16开本1印张27千字*统一书号155198·1463定价0.00元版权专有侵权必究本书如有印装质量问题,我社营销中心负责退换T/CEC226—2019T/CEC226—2019I目次前言···································································································································································II1范围······························································································································································12规范性引用文件··········································································································································13试验要求······················································································································································14试验方法······················································································································································25检验规则····················································································································································10T/CEC226—2019II前言本标准按照GB/T1.1—2009《标准化工作导则第1部分:标准的结构和编写》给出的规则起草。请注意本标准的某些内容可能涉及专利。本标准的发布机构不承担识别这些专利的责任。本标准由中国电力企业联合会提出。本标准由全国微电网与分布式电源并网标准化技术委员会(SAC/TC564)归口。本标准起草单位:江苏省电力有限公司宿迁供电分公司、江苏和网源电气有限公司、中国电力科学研究院有限公司、国网山东省电力公司电力科学研究院、陆军工程大学、东莞理工学院、常州中海电力科技有限公司、北京中电建投微电网科技有限公司、北京群菱能源科技有限公司。本标准主要起草人:王秀茹、李江、刘刚、焦道海、阮喻、李立生、蔺圣杰、郑楠、张进滨、王训金、林永清、江忠耀、代鹏、张科、邱冬、马建、黄华峰、张志、李华、赖勇、万新强、凌万水、邢晓敏、徐静、侯宝峰、李乐、马振川、张立路。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。T/CEC226—20191直流配电网DC/DC变换器试验方法1范围本标准规定了1500V及以下直流配电网用双极、双向DC/DC变换器的试验要求及试验方法。本标准适用于1500V及以下直流配电网用双极、双向DC/DC变换器。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB/T2423.1—2008电工电子产品基本环境试验第2部分:试验方法试验A:低温GB/T2423.2—2008电工电子产品基本环境试验第2部分:试验方法试验B:高温GB/T2423.4—2008电工电子产品基本环境试验第2部分:试验方法试验Db:交变湿热(12h+12h循环)GB/T2423.5—1995电工电子产品环境试验第2部分:试验方法试验Ea和导则:冲击GB/T2423.6—1995电工电子产品环境试验第2部分:试验方法试验Eb和导则:碰撞GB/T2423.10—2008电工电子产品环境试验第2部分:试验方法试验Fc:振动(正弦)GB/T3859.2—2013半导体变流器通用要求和电网换相变流器第1-2部分:应用导则GB/T4208外壳防护等级(IP代码)GB4824工业、科学和医疗(ISM)射频设备骚扰特性限值和测量方法GB/T12325电能质量供电电压偏差GB/T14549—1993电能质量公用电网谐波GB/T15543电能质量三相电压不平衡GB/T15945—2008电能质量电力系统频率偏差GB/T16935.1—2008低压系统内设备的绝缘配合第1部分:原理、要求和试验GB/T17626.2—2006电磁兼容试验和测量技术静电放电抗扰度试验GB/T17626.3—2016电磁兼容试验和测量技术射频电磁场辐射抗扰度试验GB/T17626.4—2008电磁兼容试验和测量技术电快速瞬变脉冲群抗扰度试验GB/T17626.5—2008电磁兼容试验和测量技术浪涌(冲击)抗扰度试验GB/T17626.6—2017电磁兼容试验和测量技术射频场感应的传导骚扰抗扰度GB/T17626.11—2008电磁兼容试验和测量技术电压暂降、短时中断和电压变化的抗扰度试验GB/T17626.12—2013电磁兼容试验和测量技术振荡波抗扰度试验GB/T17626.14—2015电磁兼容试验和测量技术电压波动抗扰度试验3试验要求3.1环境条件设备试验环境应符合下列条件:a)除环境试验条件外,其他试验均在测量和试验用标准大气条件下进行:T/CEC226—201921)环境温度:+15℃~+35℃。2)相对湿度:25%~75%。3)大气压力:86kPa~106kPa。4)周围环境:使用地点不得有爆炸危险介质,周围介质不含有腐蚀金属和破坏绝缘的有害气体及导电介质。b)在每一项目的试验期间,试验环境条件应相对稳定。3.2供电条件试验电源除有特殊要求外,需满足以下要求:a)公用电网谐波电压不应超过GB/T14549—1993中第4章规定的限值,电压总谐波畸变率不大于5%,奇次谐波电压含有率不大于4%,偶次谐波电压含有率不大于2%。b)三相电压不平衡度不应超过GB/T15543规定的数值,允许值为2%,短时不大于4%。c)交流输出端口20kV及以下三相电压的允许偏差为额定电压的10%,220V单相电压的允许偏差为额定电压的-15%、+10%;其他情况电网电压允许偏差应符合GB/T12325的规定。d)公用电网的频率不超过GB/T15945—2008中第4章中规定的限值,频率偏差不超过0.5Hz。3.3测量设备精度要求除另有规定外,试验中所使用的仪器仪表准确度应满足下列要求:a)测量温度仪表的误差不超过±1℃。b)测量时间用仪表:当测量时间大于1s时,相对误差不大于0.5%;测量时间小于1s时,相对误差不大于5ms。c)所有测试仪器、仪表应在计量认证的有效期内。一般使用的仪表准确度应根据被测量的误差等级按表1进行选择。表1测试仪表准确度的选择误差(0,0.5%](0.5%,1.5%](1.5%,5%](5%,7.5%]仪表最大允许误差0.1级0.2级0.5级1.0级数字仪表准确度等级6位半5位半4位半4位半3.4试验负载推荐使用无源负载。在检测电路中应使用无感阻抗、低耗电感和具有低串联有效内阻和串联有效电感的电容器。4试验方法4.1环境适应性测试4.1.1低温严酷等级试验按照GB/T2423.1—2008的“试验Ad:散热试验样品温度渐变的低温试验”进行,产品无包装,在试验温度为(-5±3)℃环境下,产品放置2h后应能够正常启动;启动在额定工况下运行保持2h后断电,在标准大气条件下恢复2h后,设备应能正常工作。注:正常工作指负载馈能装置的性能指示、显示功能都应正常,不允许有功能丧失。T/CEC226—201934.1.2高温严酷等级试验按照GB/T2423.2—2008中“试验Bd:散热试验样品温度渐变的高温试验”进行。产品无包装,在试验温度为(40±2)℃环境下,产品放置2h后应能够正常启动;启动在额定工况下运行保持2h后断电,在标准大气条件下恢复2h后,设备应能正常工作。4.1.3交变湿热严酷等级试验按照GB/T2423.4—2008的“试验Db:交变温热(12h+12h循环)”,试验温度:40℃,相对湿度:90%~100%,循环次数:2次。按照方法2给定温度条件下,无包装,不通电,试验后,取出样品,在正常环境条件下恢复2h后,设备应能正常工作。4.2性能指标检验4.2.1电压控制精度测试电压控制精度测试流程如下:a)低压侧电压误差测试。设备高压侧使用直流源分别接入75%、100%、120%额定电压,设定低压侧输出电压值,待系统处于稳定运行状态后,使用示波器对设备的低压侧进行电压值检测,并记录低压侧屏显电压值。b)高压侧电压误差测试。设备低压侧使用直流源分别接入75%、100%、120%额定电压,设定高压侧输出电压值,待系统处于稳定运行状态后,使用示波器对设备的高压侧进行电压值检测,并记录高压侧屏显电压值。4.2.2电流控制精度测试电流控制精度测试流程如下:a)低压侧电流误差测试。设备高压侧接入直流源并调至额定电压,低压侧接入负载。改变负载值,使低压侧电流设定在额定电流值的50%、75%和100%。记录低压侧屏显电流值;使用功率分析仪对设备的低压侧进行电流值检测。b)高压侧电流误差测试。设备低压侧接入直流源并调至额定电压,高压侧接入负载,改变负载值,使高压侧电流设定在额定电流值的50%、75%和100%。记录高压侧屏显电流值;使用功率分析仪对设备的高压侧进行电流值检测。电压、电流控制精度测试合格后才能进行以下测试。4.2.3低压侧恒流输出测试设备高压侧接入直流源,通入10%额定电流,低压侧接入直流负载。将功率分析仪接入设备低压侧。高压侧输入电流值以额定电流的10%为跨度上调直至额定电流,记录功率分析仪上显示的电流值。4.2.4高压侧恒流输出测试设备低压侧接入直流源,通入10%额定电流,高压侧接入直流负载。将功率分析仪接入设备高压侧。低压侧输入电流值以额定电流的10%为跨度上调直至额定电流,记录功率分析仪上显示的电流值。高、低压测恒流输出工作测试合格后才能进行恒功率输出工作测试。4.2.5低压侧恒功率输出测试设备高压侧接入直流源,通入额定电压,低压侧接入直流负载。将功率分析仪接入设备低压侧端T/CEC226—20194子。低压侧输出功率以额定功率的10%为跨度上调直至额定功率,记录功率分析仪显示的功率值。4.2.6高压侧恒功率输出测试设备低压侧接入直流源,通入额定电压,高压侧接入直流负载。将功率分析仪接入设备高压侧端子。高压侧输出功率以额定功率的10%为跨度上调直至额定功率,记
本文标题:TCEC2262019直流配电网DCDC变换器试验方法
链接地址:https://www.777doc.com/doc-6303133 .html