您好,欢迎访问三七文档
当前位置:首页 > 机械/制造/汽车 > 电气技术 > 常见氧化锌避雷器型号及参数
常见型号氧化锌避雷器0.22~0.38kV低压避雷器类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)低压(H)Y1.5WS-0.28/1.30.280.220.240.60----1.30----5010(H)Y1.5WS-0.50/2.60.500.380.421.20----2.60----50103kV配电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)配电(H)Y5WS-3.8/153.833.07.517.315.012.87540(H)Y5WS-5/15534.07.517.315.012.87540电站(H)Y5WZ-3.8/13.53.833.07.215.513.511.520065(H)Y5WZ-5/13.5534.07.215.513.511.5200653kV配电型/电站型(带脱离装置)配电(H)Y5WS-3.8/15L3.833.07.517.315.012.87540(H)Y5WS-5/15L534.07.517.315.012.87540电站(H)Y5WZ-3.8/13.5L3.833.07.215.513.511.520065(H)Y5WZ-5/13.5L534.07.215.513.511.5200656kV配电型/电站型类别避雷器型号避雷器额系统标称持续运行直流U1mA陡波冲击雷电冲击操作冲击2mS方波电4/10μs冲击电定电压kV(有效值)电压kV(有效值)电压kV(有效值)参考电压≮kV电流残压≯kV(峰值)电流残压≯kV(峰值)电流残压≯kV(峰值)流A(峰值)流kA(峰值)配电(H)Y5WS-7.6/307.666.015.034.630.025.67540(H)Y5WS-10/301068.015.034.630.025.67540电站(H)Y5WZ-7.6/277.666.014.431.027.023.020065(H)Y5WZ-10/271068.014.431.027.023.0200656kV配电型/电站型(带脱离装置)配电(H)Y5WS-7.6/30L7.666.015.034.630.025.67540(H)Y5WS-10/30L1068.015.034.630.025.67540电站(H)Y5WZ-7.6/27L7.666.014.431.027.023.020065(H)Y5WZ-10/27L1068.014.431.027.023.02006510kV配电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)配电(H)Y5WS-12/35.8(1)12109.618.041.235.830.67540(H)Y5WS-15/45.6(2)151012.023.052.545.639.07540(H)Y5WS-12.7/5012.71010.225.057.550.042.57540(H)Y5WS-16.5/5016.51013.225.057.550.042.57540(H)Y5WS-17/50171013.625.057.550.042.57540电站(H)Y5WZ-12/32.4(1)12109.617.437.232.427.620065(H)Y5WS-15/40.5(2)151012.021.846.540.534.520065(H)Y5WZ-12.7/4512.71010.224.051.845.038.320065(H)Y5WZ-16.5/4516.51013.224.051.845.038.320065(H)Y5WZ-17/45171013.624.051.845.038.32006510kV配电型/电站型(带脱离装置)配电(H)Y5WS-12/35.8L(1)12109.618.041.235.830.67540(H)Y5WS-15/45.6L(2)151012.023.052.545.639.07540(H)Y5WS-12.7/50L12.71010.225.057.550.042.57540(H)Y5WS-16.5/50L16.51013.225.057.550.042.57540(H)Y5WS-17/50L171013.625.057.550.042.57540电站(H)Y5WZ-12/32.4L(1)12109.617.437.232.427.620065(H)Y5WS-15/40.5L(2)151012.021.846.540.534.520065(H)Y5WZ-12.7/45L12.71010.224.051.845.038.320065(H)Y5WZ-16.5/45L16.51013.224.051.845.038.320065(H)Y5WZ-17/45L171013.624.051.845.038.320065注:(1)—此型避雷器用于中性点经低电阻接地的电网;(2)—此型避雷器用于中性点经消弧线圈接地的电网。3~10kV并联补偿电容器型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)并联补偿(H)Y5WR-5/13.5534.07.2----13.510.540065电容器型(H)Y5WR-10/271068.014.4----27.021.040065(H)Y5WR-12/32.41269.617.4----32.425.240065(H)Y5WR-15/40.5151012.021.8----40.531.540065(H)Y5WR-17/46171013.624.0----46.035.04006520kV配电型/电站型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)配电(H)Y5WS-26/68262020.834.078.268.057.87540(H)Y5WS-26/72262020.836.082.872.061.27540电站(H)Y5WZ-30/80302024.043.092.080.068.020065(H)Y5WZ-32/84322027.245.096.784.071.52006520kV配电型/电站型(带脱离装置)配电(H)Y5WS-26/68L262020.834.078.268.057.87540(H)Y5WS-26/72L262020.836.082.872.061.27540电站(H)Y5WZ-30/80L302024.043.092.080.068.020065(H)Y5WZ-32/84L322027.245.096.784.071.52006535kV电站型/35kV并联补偿电容器型类别避雷器型号避雷器额定电压kV系统标称电压kV(有效持续运行电压kV(有效直流U1mA参考电压陡波冲击电流残压雷电冲击电流残压操作冲击电流残压2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)(有效值)值)值)≮kV≯kV(峰值)≯kV(峰值)≯kV(峰值)电站(H)Y5WZ-42/134423533.673.015413411440065(H)Y5WZ-51/134513540.873.015413411440065(H)Y5WZ-52.7/13452.73542.273.015413411440065(H)Y5WZ-54/134543543.273.015413411440065并联补偿电容器用(H)Y5WR-42/134423533.673.0----13410540065(H)Y5WR-51/134513540.873.0----13410540065(H)Y5WR-52.7/13452.73542.273.0----13410540065(H)Y5WR-54/134543543.273.0----134/,DIV105,/DIV40065注:以上型号避雷器上端均可采用硅橡胶高压软电缆引出(默认长度0.6M)。发电机型/电动机型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)外形尺寸发电机用(H)Y5WD-4/9.543.153.25.710.79.57.640065同10kV电容器型(H)Y5WD-8/18.786.36.311.221.018.715.040065(H)Y5WD-13.5/3113.510.510.518.634.731.025.040065(H)Y5WD-17.5/4017.513.813.824.444.840.032.040065同10kV电容器型(H)Y5WD-20/452015.815.828.050.445.036.040065(H)Y5WD-23/512318.218.031.957.251.040.840065(H)Y5WD-25/56.22520.220.035.462.956.245.040065电动机用(H)Y2.5WD-4/9.5433.25.710.79.57.620065同3kV电站型(H)Y2.5WD-8/18.7866.311.221.018.715.020065同6kV电站型(H)Y2.5WD-13.5/3113.51010.518.634.731.025.020065同10kV电站型电机中性点型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压≯kV(峰值)雷电冲击电流残压≯kV(峰值)操作冲击电流残压≯kV(峰值)2mS方波电流A(峰值)4/10μs冲击电流kA(峰值)外形尺寸电机中性点用(H)Y1.5WD-2.4/62.43.151.93.4----6.05.020065同10kV电容器型(H)Y1.5WD-4.8/124.86.33.86.8----12.010.020065(H)Y1.5WD-8/19810.56.411.4----19.015.920065同10kV电容器型(H)Y1.5WD-10.5/2310.513.88.414.9----23.019.220065(H)Y1.5WD-12/261215.89.617.0----26.021.640065同10kV电容器型(H)Y1.5WD-13.7/29.213.71811.019.5----29.224.340065(H)Y1.5WD-15.2/31.715.22012.221.6----31.726.440065变压器、电抗器中性点型类别避雷器型号避雷器额定电压kV(有效值)系统标称电压kV(有效值)持续运行电压kV(有效值)直流U1mA参考电压≮kV陡波冲击电流残压
本文标题:常见氧化锌避雷器型号及参数
链接地址:https://www.777doc.com/doc-6337098 .html