您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > DLT9132005火电厂水质分析仪器质量验收导则
DL/T913—2005I目次前言··································································································································································Ⅱ1范围·····························································································································································12规范性引用文件··········································································································································13验收条件······················································································································································14验收规则······················································································································································25验收内容······················································································································································4附录A(资料性附录)火电厂水质分析仪器质量验收报告格式······························································7附录B(资料性附录)火电厂水质分析仪器与上位机通信协议····························································10附录C(资料性附录)水质分析仪器异常与故障的判定········································································17DL/T913—2005II前言本标准是根据原国家经济贸易委员会《关于下达2002年度电力行业标准制、修订计划项目的通知》(国经贸电力[2002]937号文)的安排编制的。本标准与GB/T19022.1—1994(idtISO10012-1:1992)《测量设备的质量保证要求第一部分测量设备的计量确认体系》相一致。本标准提出了建立火电厂水质分析仪器质量检查验收的主要要素,而且提供了实现这些要素的具体规定和方法,以满足电厂化学仪表检验/校准实验室计量确认工作。力求对新购置水质分析仪器的质量检查验收标准达到统一,从而规范质量控制、质量检查验收与质量保证。实践证明水质分析仪器的质量检查验收工作,是提高测量结果的准确性、应用的可靠性,提高化学技术监督水平、保障发电机组安全、经济生产的重要措施之一。本标准可以为水质分析仪器采购提供技术依据。本标准的附录A、附录B、附录C为资料性附录。本标准由中国电力企业联合会提出。本标准由电力行业电厂化学标准化技术委员会归口并解释。本标准起草单位:北京大唐发电股份有限公司、河北省电力研究院、河北瑞特电力科技有限公司。本标准主要起草人:王二福、吴仕宏、安洪光、张辰光。DL/T913—20051火电厂水质分析仪器质量验收导则1范围本标准规定了火电厂常用的水质分析仪器*,包括:电导率仪、酸度计、钠离子监测仪、溶解氧分析仪、硅酸根分析仪五种水质分析仪器的质量验收条件、验收规则与验收内容。本标准适用于新购置的国产与进口水质分析仪器的质量验收,也适用于已投产使用的水质分析仪器在应用中的质量检查验收。2规范性引用文件下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。GB191包装储运图示标志GB/T4026—2004人机界面标志标识的基本方法和安全规则设备端子和特定导体终端标识及字母数字系统的应用通则GB9969.1工业产品的使用说明书总则GB/T15464仪器仪表包装通用技术条件DL/T677火力发电厂在线工业化学仪表检验规程国家计量局[1987]量局法字第231号中华人民共和国依法管理计量器具目录国家计量局1987-07-10国家技术监督局[1989]第3号中华人民共和国进口计量器具监督管理办法国家技术监督局1989-11-043验收条件3.1定货合同应符合我国相关法律、法规及标准并有明确质量要求的条款或技术协议。3.2供货方应随同产品向用户提供符合要求的随机文件、资料。3.3对于外购进口水质分析仪器应按照《中华人民共和国进口计量器具监督管理办法》的规定进行。3.4对于购买已列入《中华人民共和国依法管理计量器具目录》中的产品,供货方应向用户提供产品所取得的法定资质证明材料。3.5新购入的分析仪器所进行的测量应能溯源到国家标准或国际基准,对于无法开展量值传递或量值溯源的仪器,不宜进入质量验收程序。3.6供货方所提供的配套传感器一般不超过一年,电位式分析仪器中应用的离子选择性电极的生产日期距向用户供货的时间:国产电极不宜超过6个月,进口电极不宜超过8个月,对于没有生产日期或已超过期限的电极都不能进入质量检查验收程序。*以测量物质的化学组成、结构及某些物理特性的仪器称为分析仪器,本标准中对火电厂用于水汽质量监测的在线式工业化学仪表与离线式实验室仪器统称水质分析仪器。DL/T913—200524验收规则4.1新购置水质分析仪器的质量检查验收程序见图1。图1新购置水质分析仪器质量检查验收操作程序4.2形式检验4.2.1符合验收条件各项规定的分析仪器可以进入形式检验操作程序。4.2.2以外观检查为主的形式检验程序由用户单位进行,形式检验结束后应填写形式检验报告,报告格式参见附录A中的表A.1。4.2.3形式检验要求1)到货仪器的标志、包装、运输、贮存应符合GB191、GB/T15464的规定。2)随机文件应与实际供货仪器相符,说明书应符合GB9969.1的规定。4.3性能测试4.3.1形式检验合格的分析仪器可以进入性能测试操作程序。4.3.2性能测试应由已通过电力行业化学仪表实验室计量确认评审合格的检验机构和具有电力行业化学仪表检验员计量确认资质证书的人员进行。用户单位可按照电力技术监督网和就近原则主动送检,检验机构在收到送检仪器后应在两个月内向用户提供检验测试报告,报告格式见DL/T677。4.3.3测试项目与技术要求安全性能测试项目与技术要求见表1,技术指标测试项目与技术要求见表2~表7。表1分析仪器安全性能测试项目与技术要求测试项目技术要求绝缘电阻1kV/20MΩ耐压试验2kV50Hz/1min,无击穿、无飞弧表2电导率分析仪器的测试项目与技术要求测试项目技术要求仪表级别级3210.5基本误差δJ%FS±3.00±2.00±1.00±0.50整机配套检验温度补偿附加误差δt×10−2/10℃±1.50±1.00±0.50±0.25DL/T913—20053表2(续)测试项目技术要求引用误差δY%FS±1.50±1.00±0.50±0.25示值重复性δC1.501.000.500.25二次仪表示值稳定性δD×10−2/d±1.50±1.00±0.50±0.25电极常数误差aδw%±1.50±1.00±1.00±1.00a对于具有电极常数修正设定功能的分析仪器,其电极常数误差(δw)指标允许扩展一倍表3酸度计分析仪器的测试项目与技术要求测试项目技术要求仪表级别级0.20.10.050.01pH示值误差δW±0.20±0.10±0.05±0.01每变化10℃pH补偿附加误差±0.10±0.05±0.03±0.005整机配套测试示值重复性S0.100.050.030.005pH引用误差(ΔpH)±0.10±0.05±0.03±0.005二次仪表测试输入阻抗引起的pH示值误差(pHR)±0.06±0.03±0.01±0.005表4酸度计分析仪器电极的测试项目与技术要求技术要求测试项目复合电极玻璃电极甘汞电极电极内阻RNMΩ≤5005~20(低阻电极)100~250(高阻电极)≤0.1百分理论斜率PTS%≥95(工业电极)≥97(实验室电极)≥95—与标准甘汞电极比较电位差(绝对值)≤3mV/8h(0.375mV/h)电极电位稳定性≤±2mV/8h或0.25mV/h液络部位渗透速度—可检出/5min或≤0.005mL/min表5钠离子监测分析仪器的测试项目与技术要求测试项目技术要求仪表级别级0.050.01pNa分度值或最小有效显示值±0.050±0.010pNa示值误差δW±0.050±0.010每变化10℃pNa补偿附加误差δt±0.025±0.005整机配套测试重复性误差S0.0250.005pNa引用误差(ΔpNa)±0.025±0.005二次仪表测试输入阻抗Ω≥3×1011≥1×1012DL/T913—20054表6溶解氧分析仪器的测试项目与技术要求测试项目技术要求仪表级别级10531整机基本误差δJ%FS±10.0±5.0±3.01.0整机示值稳定性δD×10−2/d±5.0±2.5±1.50.5整机示值重复性S5.02.51.50.5传感器流路系统严密性能在充0.29MPa风压下,压力下降速度不大于0.0098MPa/h表7硅酸根分析仪器的测试项目与技术要求测试项目技术要求仪表级别级3.02.01.0整机基本误差δJ%FS±3.0±2.0±1.0整机示值稳定性δD×10−2/d±1.5±1.0±0.5整机示值重复性δC1.51.00.5抗磷酸盐干扰性能a在磷酸盐含量为5mg/L时,产生的正向误差≤2μg/L;在磷酸盐含量为30mg/L时,产生的正向误差≤4μg/La抗磷酸盐干扰性能测试只适用于测量炉水的“大硅表”,对用于测量蒸汽或化学净水处理的“小硅表”可以不检此项4.4实用性考核4.4.1性能测试合格的分析仪器可以进入实用性考核操作程序。4.4.2实用性考核就是在现场以检查分析仪器实用性为目的的一项考核内容,实用性考核由已取得电力行业化学仪表检验员计量确认资质证书的人员进行,实用性考核结束后应填写实用性考核报告,报告格式参见附录A中的表A.2。4.4.3考核时间与技术要求。实用性考核时间与技术要求见表8。表8实用性考核时间与技术要求分析仪器形式考核时间技术要求在线式工业分析仪器连续运行168h离线式实验室分析仪器7d,每天开机时间不少于6h不同性质的异常次数不大于2次且无故障发生4.5质量验收结束4.5.1在进行形式检验、性能测试与实用性考核程序验收全部合格的分析仪器,可以进入质量验收结束操作程序。4.5.2质量验收结束程序是对质量验收全过程的书面总结,将质量验收报告上报有关部门并存档,质量验收结束操作程序由用户单位负责,报告格式参见附录A中的表A.3。5验收内容5.1形式检验验收内容5.1.1标志、包装、运输、贮存5.1.1.1供货方所提供产品的包装、运输、贮存应符合GB191
本文标题:DLT9132005火电厂水质分析仪器质量验收导则
链接地址:https://www.777doc.com/doc-6535881 .html