您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 质量控制/管理 > NPW150manual简体中文
NPW-150型1开始(a)真诚感谢使用本产品。氮·磷/COD自动测量装置—NPW-150,该仪器可以自动测量工矿企业的排水以及河川、湖泊的排水中含氮·磷/COD浓度。例:氮·磷/COD自动测量系统(b)这个产品,作为富营养化防止对策在水质污染防止法中被规定,氮·磷与环境基准及排水基准的测量对应着。(c)本产品采用120℃二硫酸钾分解法—紫外线吸光光度法对总氮测定和120℃二硫酸钾分解法—钼青吸光光度法对总磷测定。对COD测定采用紫外线吸光光度法。(d)本产品的测定采用1流路自动采水系统,氮·磷/COD自动测定。(e)贩卖品和纯水器组合的时,请参照下一项目。参照8.1内藏型纯水器8.2设备以外的纯水注入下表为主要的方法。NPW-150試料水泵排水受水槽PDFcreatedwithpdfFactoryProtrialversion主要的方法方法项目内容测定対象水中的氮·磷/COD浓度测定方法TN:采用120℃peruokiso二硫酸钾分解法-紫外线吸光光度法的总氮测量TP:采用120℃peruokiso二硫酸钾分解法-钼青(Ascorbicacid)吸光光度法的总磷测量COD:2波长吸光光度法(紫色线254nm/可见光546nm)測定范围TN:0~20~200mg/L从(超越0~5mg/L的时候采用稀释水样测量)TP:0~0.50~20mg/L从(超越0~2mg/L的时候采用稀释水样测量)COD:0~200~500mg/L测定周期同时测量,1小时/1测量的间歇测量(1~6小时设定可)流路1点(f)这个产品,在分析构筑该系统时,需要根据该系统的特性,需要注意避免不必要的损伤,电缆的绝缘不良,周围的电磁干扰,不恰当的运转条件的设定和校对操作,其它不预期的现象及异常的动作。(g)「为了安全」,该标记表示有重要的事记载着,请特别仔细阅读。(h)对产品和药品的管理维护,需要专业的技术人员负责。对于技术方面的修理则由此产品制造商进行修理,或者由产品制造商指定的公司进行修理。PDFcreatedwithpdfFactoryProtrialversion安全—注意(1)记号的意义・·对说明书书中的说明和警告标签,以及其它的记号的意义,如下表所述。・警告标签的警报标记为(),该标记告知危险的存在,详细请请参照对应的说明书。警告:如果不回避,就有可能出现死亡或重伤的状况。如出现事故,烧伤(高温,低温),触电,骨折,中毒等,有后遗症残留或需治疗及长期住院等。【重要】:防止产品实体的破损,数据的丢失,时间的浪费等,表示为了性能维护等的重要的事项。〔备考〕:表示为了加深理解的解说,理由,特例等的事。:表示参照项目。①②③…:表示操作等的项目号码。请按号码的按顺序做操作。注意:如果不回避,就可能造成受轻伤或者物品的损失。PDFcreatedwithpdfFactoryProtrialversion(2)安全上的注意警告有害物注意●使用的试剂的大部分是含有害物的。并且,废液也含有害物。这些,请做好必要的防护工作。小心眼和皮肤。如果,皮肤和眼及衣服不小心接触到时,请立刻用水冲洗,有异常的时候,立即就医。气体等的注意●请别在有爆炸性气体,腐蚀性气体,可燃性气体等的地方使用。有爆炸,着火的可能。触電注意●电源供给中,请别触及内部及外部连接终端。有触电的可能。●接地终端请必定接地。电源系统内部有发生漏电的可能性。注意電源供电注意●请别超过电源的电压范围。请留神其他的终端连接。拆卸・改造的注意●请别自行拆卸改造说明书未说明的部分。否则会带来机器故障。固定放置注意●用底座螺栓等固定,请务必使用。这个装置是重物(约80kg),跌倒的话,会带来人员或设备的损伤。警告标签遗失的注意●贴上的警告标签变得不能读或者遗失的时候,应及时向销售公司联系后,粘贴回原位置。废弃物的注意●盐酸,钼酸铵,是pH1.0以下的酸性溶液。同时,氢氧化钠溶液是pH13以上的碱性溶液。废弃的时候,应参照工业上废物处理有关条例处理。操作的时候要注意不要直接接触皮肤,须采取防腐措施。PDFcreatedwithpdfFactoryProtrialversion制品的保证(a)产品在保质期内出现故障时,无偿修理。但是,若以下问题,即使是在保修期内也要收修理费。1不恰当的操作,超出产品说明书所提及的应用范围外的使用,不适当的维护,修理,改造等引起的故障,损伤。2不恰当的使用易耗品,零部件,导致机器软硬件等的故障·损伤。3由和仪器连接的外部设备引起的故障·损伤。4由于交货后的运输,移动,落下等导致的故障·损伤。5火灾,天灾地变(地震,风灾与水灾,打雷等),由于腐蚀性气体,煤气危害,异常电压等导致的故障,损伤。(b)保质期期限,自产品交付使用日起1年。若,交付时间不明确的时候,则从在产品铭牌上标记的制造年月的下月开始作为24个月保质时间。(c)保质的对象物,只限于本产品。(d)超过说明书所说明的应用范围以外使用的,和使用方法不恰当,直接或间接产生的损失,我们不承担责任。(e)保质的对象地区是日本国内。关于在日本国外的使用,则需根据个别的契约保证。(f)若在上述情况以外,本公司产品的故障,损伤的质报量保证,本公司根据相关法律的规定承担责任。(g)其它:1这个产品的修理用零部件的最低保有期间,制造停止后是5年。2实验室用便携式分析计等小型的产品类,在DKK公司修理。PDFcreatedwithpdfFactoryProtrialversion读法向导请根据下图理解产品的概要,起动产品,进行维护检查等工作,参照这个说明所列的项目和顺序。图中的带圈数字,主要是参照的项目和顺序。目的別の参照項目开始动作制品概要的理解设置的确认目的章节个别的操作维护点検,故障対策9.方法动作说明8.附加机能7.故障対策6.保守●开始5.目的操作4.校正3.测定的开始和停止2.测定前的准备1.操作部件的机能●为了安全10.设置PDFcreatedwithpdfFactoryProtrialversion目次●在开始时··············································································································································1●为了安全··············································································································································3(1)记号类的意思·······································································································································3(2)安全上的注意·······································································································································4●产品的保证·····································································································································5●读法向导··············································································································································61.操作部的机能····························································································································121.1各部分的名愁·······································································································································12(1)主要部的名称····································································································································12(2)操作部的名称····································································································································131.2画面的机能···········································································································································15(1)画面的读法·········································································································································15(2)操作画面图·········································································································································162测量前的准备···························································································································192.1试剂的制作············································································································································19(1)试剂的种类·········································································································································19(2)peruokiso二硫酸钾溶液的制作··············
本文标题:NPW150manual简体中文
链接地址:https://www.777doc.com/doc-6539289 .html