您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 信息化管理 > 贝朗DIALOG+透析机水路设计概览
Dialog+FlowDiagrams水路设计概览贝朗爱敦(上海)贸易有限公司维修部技术经理崔波2010年4月8日Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.2TTSHEFlowDiagram水路图可分成六个节段:1、进水节段2、除气和加热节段3、配比透析液节段4、平衡腔容量控制节段5、超滤控制节段6、冲洗桥节段Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.3WaterInlet,DegassingandHeating进水节段,除气和加热节段进水口排水口TTSHE进水部分DMV:减压阀RVVB:进水电磁阀WT:热交换器VB:水箱NSVB:水箱液位传感器除气部分RVE:除气比例阀PE:除气压力传感器EK:除气室EP:除气泵加热部分TSHE:加热前温度传感器H:加热棒TSH:加热棒高温保护TSE:加热后温度传感器Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.4WaterUplineTank水箱填充水箱,整个压力通路通畅高水位触点关闭进水阀门低水位触点自动停止加热,泵停转中水位(低于高位触点)打开进水阀门注意:浮球上的三角标识指示装配方向经除气和加热后的反渗水反渗水高水位限位圈Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.5去除气和加热节段经除气和加热后的反渗水除气和加热后的反渗水部分溢流至3/2部分去配比透析液阶段反渗水进水WaterUplineTank水箱进水减压阀DMV控制进水箱反渗水压力不高于1.3BarAuthors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.6DialysatePreparation配比透析液节段进水口排水口BicconcentrateB液acidicconcentrateA液TTSHEBICP:B液泵RVB:B液单向阀TSBIC:B液温度传感器BICLF:B液电导度传感器KP:A液泵RVK:A液单向阀ENDLF:总电导度传感器ENDLF_S:ENDLF的检测信号TSD:透析液温度传感器TSD_S:TSD的检测信号FPE:正压泵RVFPE:FPE的高压保护阀Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.7MainFlow/Bypass主水路/旁路Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.8MainFlow/Bypass主水路/旁路Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.9BalanceChamber平衡腔透析液dialyser透析器用后透析液+超滤液FPE:正压泵FPA:负压泵BK1/2:平衡腔室1/2MSBK1/2:平衡腔膜位移传感器VEBK:透析液进平衡腔电磁阀VDEBK:透析液出平衡腔电磁阀VDABK:废液进平衡腔电磁阀VABK:废液出平衡腔电磁阀Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.10BalanceChamberPhase1平衡腔容量平衡1阶段正压泵平衡腔LA(空气分离室)FPA(负压泵)UFP(超滤泵)BLDPDADDE:透析液节流阀RVDA:废液节流阀PDA:废液压力传感器BLD:漏血传感器Authors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.11BalanceChamberPhase2平衡腔容量平衡2阶段正压泵空气分离室负压泵超滤泵平衡腔BLDPDAAuthors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.12•持续监测平衡腔膜片位置持续控制,腔体内压力稳定,阀门切换对流速影响小•透析器内没有压力突变超滤平稳并且避免了平衡腔切换时产生反超•透析液持续不断(包括液流切换时刻)维持住弥散压力可带来更好的治疗效果(K*t/V值)•对膜片、阀门和泵都有保护作用延长配件寿命AdvantagesoftheDialogBalanceChamberControlDialog改良的平衡腔控制系统的优点Dialog+WettbewerbAuthors:GuenterNissenHeikoRiemenschneider10/09/2020Trainingdocument,noupdateservice.Thisdocumentmaynotbecopied,partlyorwhole,ormadebeaccessibletothirdpartieswithoutourpermissionandremainsthepropertyofB.BraunMedizintechnologieGmbHwithallrights.13MainFlow/Bypass主水路/旁路(安全性设计)净的透析液废液:透析液+超滤液通向除气部分透析器VBP:旁路阀VDE:透析液出机器电磁阀VDA:废液回机器电磁阀LA:空气分离室VLA:空气分离阀Authors:GuenterNissenHeikoRiemenschneider10/09/202014FlowDiagramDisinfection消毒循环回路waterinletdialysateoutlet消毒液通大气软管TTSHEVD:消毒阀VZ:循环阀Authors:GuenterNissenHeikoRiemenschneider10/09/202015谢谢。我的联系方法:021-22163398Bo.cui@bbraun.com我们的共同目标!追求人生的美好!
本文标题:贝朗DIALOG+透析机水路设计概览
链接地址:https://www.777doc.com/doc-6908493 .html