您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > JB-T 10164-1999 主令开关
ICS29.120.60K31JB/T10164-1999主令开关Hostorderlimitswitches1999-10-08发布2000-03-01实施国家机械工业局发布I前言1范围····················································································································································································································12引用标准·········································································································································································································13术语、符号、代号····················································································································································································14要求····················································································································································································································35抽样··················································································································································································································176试验方法·······································································································································································································197标志、包装、运输、贮存···································································································································································36JB/T10164-1999目次II前言本标准是依据GB/T14048.1—1993《低压开关设备和控制设备总则》及GB14048.5—1993《低压开关设备和控制设备控制电路电器和开关元件第一部分:机电式控制电路电器》制定的。同时引用了JISC4520—1978(1991确认)控制开关标准的相应条款。本标准由机床电器标准化技术委员会提出。本标准由成都机床电器研究所归口。本标准起草单位:北京第一机床电器厂。本标准主要起草人:刘竟存、卓维中、周向东。JB/T10164-199911范围本标准规定了主令开关通用的基本要求,包括术语、特性、型式、参数、正常工作条件和安装条件、结构、性能要求、特性和性能的验证。本标准适用于额定电压交流50Hz(或60Hz)、电压至660V,直流电压至440V,额定工作电流至10A的电路中,作为远距离接通和分断电路以及手动操作的控制电器。2引用标准下列标准所包含的条文,通过在本标准中引用而构成为本标准的条文。本标准出版时,所示版本均为有效。所有标准都会被修订,使用本标准的各方应探讨使用下列标准昀新版本的可能性。GB/T1980—1996标准频率GB/T2423.1—1989电工电子产品基本环境试验规程试验A:低温试验方法GB/T2423.2—1989电工电子产品基本环境试验规程试验B:高温试验方法GB/T2423.4—1993电工电子产品基本环境试验规程试验Db:交变湿热试验方法GB/T2423.10—1995电工电子产品环境试验第二部分:试验方法试验Fc和导则:振动(正弦)GB/T2828—1987逐批检查计数抽样程序及抽样表(适用于连续批的检查)GB/T2900.1—1992电工术语基本术语GB/T2900.18—1992电工术语低压电器GB/T4026—1992电器设备接线端子和特定导线线端的识别及应用字母数字系统的通则GB/T4205—1984控制电气设备的操作件标准运动方向GB/T4207—1984固体绝缘材料在潮湿条件下相比漏电起痕指数和耐漏电起痕指数的测定方法GB/T4942.2—1993低压电器外壳防护等级GB/T5169.4—1985电工电子产品着火危险试验:灼热丝试验方法和导则GB/T5226.1—1996工业机械电气设备第一部分:通用技术条件GB/T14048.1—1993低压开关设备和控制设备总则GB14048.5—1993低压开关设备和控制设备控制电路电器和开关元件第一部分;机电式控制电路电器3术语、符号、代号3.1一般定义国家机械工业局1999-10-08批准中华人民共和国机械行业标准主令开关HostorderlimitswitchesJB/T10164-19992000-03-01实施JB/T10164-19992本标准的定义未做规定者可参见GB/T2900.1、GB/T2900.18、GB/T14048.1、GB14048.5及GB/T5226.1等标准。3.2补充定义3.2.1操作件在外力作用下的动作的执行部分。3.2.2元件电气设备组成部分,通常按用途区分,但可用于各种用途。3.2.3控制装置控制装置是一个通用定义,包括开关器件及其相关控制、测量、保护和调节设备的组合,也包括这些器件及其设备与相关内部连接、辅助装置、护壳和支承结构的组合,一般供消耗电能的设备控制之用。3.2.4器件电气系统中一种起传递作用但不是利用电能的元件。3.2.5裸露导体电气设备易被触及的,平时不带电,但在故障情况下可能带电的外露导体。3.2.6防护体用于防止无意直接触电,但不能有意直接触电的一种部件。3.2.7开关器件用来接通或断开一个或几个电路电流的器件。3.2.8闭合使电器的动静触头在规定位置上建立电接触的操作过程。3.2.9断开使电器的动静触头在规定位置上解除电接触的操作过程。3.2.10人力控制由人力参与操作的控制。3.2.11有关人力操作;直接动力操作决定于操作者的动作。3.2.12复位动作了的电器所有可动部分回复到起始位置。3.2.13操作循环从一个位置转换到另一个位置再返回起始位置的连续操作,如有多个位置则需通过所有其他位置。3.2.14控制电路电器主要用于控制受电设备,使其达到预期要求的工作状态的电器。3.2.15多方向开关用手柄在规定的几个方向运动,使触头通断的控制开关。3.2.16钮子开关JB/T10164-19993用手指使手柄在相反的两个方向运动,使触头通断的控制开关。3.3符号和缩略语3.3.1符号本标准采用GB/T14048.1—1993中3.2规定的符号及定义。3.3.2代号本标准采用GB/T14048.1—1993中3.3规定的代号及其名称。4要求4.1分类与命名4.1.1分类4.1.1.1按种类分a)普通型;b)组合型。4.1.1.2按触头对数分a)一对接通触头和/或一对分断触头;b)二对接通触头和/或二对分断触头;c)三对接通触头和/或三对分断触头;d)四对接通触头和/或四对分断触头;e)其它组合方式。4.1.1.3按触头元件用途分a)速动触头元件;b)从动触头元件。4.1.1.4按触头复位方式均为非自动复位。4.1.1.5按保护方式分a)开启式;b)防护式。4.1.1.6按非自动控制操动器型式分a)十字型手柄;b)旋把式;c)手柄式;d)扳钮式;e)脚踏式;f)按钮式。4.1.1.7按控制电路分a)一个电路;b)二个电路;JB/T10164-19994c)三个电路;d)四个电路;e)多于四个电路。4.1.1.8其它4.1.1.8.1按控制角度分。4.1.1.8.2其它。4.1.2命名根据主令开关的使用用途在具体产品标准中规定。4.2正常工作条件和安装条件符合本标准的主令开关应在以下规定的条件中正常运行。4.2.1正常工作条件4.2.1.1周围空气温度a)周围空气温度上限为+40℃,24h内其平均值不超过+35℃;b)周围空气温度下限为–5℃。周围空气温度是指主令开关附近周围的空气温度,而对具有外壳的主令开关,则是指外壳附近的周围空气温度。4.2.1.2海拔安装地点的海拔不超过2000m。4.2.1.3大气条件4.2.1.3.1湿度安装地点的空气相对湿度在昀高温度为+40℃时不超过50%,在较低温度下可以有较高的相对湿度,昀湿月的月平均温度不超过+25℃,该月的月平均昀大相对湿度不超过90%。由于温度变化发生在产品上的凝露情况必须采取措施。4.2.1.3.2污染等级主令开关的污染等级规定为“污染等级3”,除非具体产品标准另有规定或只有在有效地使用外壳、防护涂层或密封方法后才有可能降低至“污染等级2”。这取决于主令开关的特殊用途或微观环境。4.2.1.4振动主令开关应能在频率为10~55Hz、振幅为0.75mm(10g)的振动条件下工作。4.2.2安装条件主令开关安装条件由具体产品标准规定。4.2.2.1安装类别主令开关安装类别为“安装类别Ⅱ”。4.2.2.2安装a)安装角度主令开关可任意安装。b)安装方式主令开关采用紧固件安装。JB/T10164-199954.3基本要求4.3.1基本参数4.3.1.1额定绝缘电压Ui主令开关额定绝缘电压规定为660,380,220,110V。对于未明确规定额定绝缘电压的主令开关,应将额定工作电压的昀大值视为额定绝缘电压。4.3.1.2约定发热电流Ith主令开关的约定发热电流规定为3,5,10,16A。4.3.1.3额定工作电压Ue和额定工作电流Ie见表1。表1电流种类额定工作电压UeV额定工作电流IeA交流24,48,110,220,380,660直流24,48,110,220,4400.16,0.2,0.25,0.315,0.4,0.5,0.63,0.80,1.0,1.25,1.60,2.0,2.50,3.15,4.0,5.0,6.30,8.00,10.04.3.1.4额定频率主令开关的额定频率应符合GB/T1980中的规定,具体额定频率由具体产品标准规定。4.3.2额定工作制正常情况下,主令开关要考虑以下工作制。4.3.2.1八小时工作制4.3.2.2不间断周期工作制4.3.2.3断续周期工作制4.3.2.4短时工作制4.3.2.5周期工作制4.3.3使用类别主令开关通常选用的使用类别及其代号见表2。表2电流种类使用类别代号典型用途举例AC–12控制电阻负载和光耦合器隔离的固态负载AC–13控制变压器隔离的固态负载AC–14
本文标题:JB-T 10164-1999 主令开关
链接地址:https://www.777doc.com/doc-7904572 .html