您好,欢迎访问三七文档
当前位置:首页 > 办公文档 > 会议纪要 > 酒店管理会所 酒店设计标准8会议设施
希尔顿酒店设计和施工标准1叶予舜1/29/201210:55:04PM第8节会议设施8a.BALLROOM宴会厅8b.MEETINGROOMS会议室8c.BOARDROOMS董事会议室8d.PREFUNCTIONAREA宴会前厅希尔顿酒店设计和施工标准2叶予舜1/29/201210:55:04PM第8a节宴会厅8a-1.00GENERAL8a-1.00总则8a-1.01Allhotelsmusthaveaminimumsizeballroomof5,000squarefeet(465m),divisibleintoaminimumofthreesections.Totalfunctionarea(meetingroomsandballroom)shallbeaminimumof7,500sq.ft(697m).所有酒店必须设有面积最小为465平方米的宴会厅,至少可分为三部分。整个功能区(会议室和宴会厅)的最小面积应为697平方米。8a-1.02Publicaccesstotheballroomshallbedirectlyfromthemainprefunctionarea.Prefunctionareashouldbeapproximately35%oftheballroomarea.在主宴会前厅应提供通住宴会厅的公用通道。主宴会前厅应为宴会厅面积的35%左右。8a-1.03Guestsandvisitorsshouldarriveattheballroomviatheballroomlobby/prefunctionareafromtheguestelevators,publiccorridorsoraseparateballroomstreetentrance.客人和来访者可从客人电梯、公用走廊或独立的宴会厅街道入口,再经过宴会厅大堂/宴会前厅区到达宴会厅。8a-1.04Whentheballroomisnotlocatedonthegroundfloorofthehotel,agrandstaircaseand/orescalatorsand/orseparateelevator(s)leadingfromthestreetentrancetotheballroomlevelissuggested.如果宴会厅不在酒店首层,建议通过正面大楼梯和/或手扶电梯和/或独立的手扶电梯从街道入口通往宴会厅楼层。8a-1.05Barrier-freeaccesstotheballroomisrequired.应设有通往宴会厅的无障碍通道。8a-1.06Theballroomandamajorityofthemeetingroomsmustbeonthesame希尔顿酒店设计和施工标准3叶予舜1/29/201210:55:04PMlevel.Locateballroomandmeetingroomsonthesamelevelasthemainkitchenwhenpossible.宴会厅必须和主要的会议室在同一楼层。尽可能将主厨房设在与宴会厅和会议室同一楼层。8a-1.07Directaccessviaservicecorridormustbeprovidedfromthekitchenorballroompantryforfoodandbeverageservicetotheballroom.Thisaccessmaynotcrosspubliccorridors.厨房或宴会厅备餐间须可通过服务走廊直接通往宴会厅,以方便提供餐饮服务不可穿过公共走廊通行。8a-1.08Provideavestibuleforentryintoeachballroomfromtheservicecorridor.Vestibulesarerequiredtoreducelightandnoisetransmissionfromtheservicecorridor.在服务走廊和每个宴会厅之间设置前室。前室应可减少由服务走廊穿透过来的光线和杂音。8a-1.09Optimumballroomroomdimensionsshallbedeterminedbypossiblebanquettablearrangements.Theuseof72‖(1.8m)diameterroundtablesisgenerallypreferred.最合理的宴会厅房间面积应由宴会餐桌的安排来决定。最好使用直径1.8米的圆桌。8a-1.10Itisrecommendedthatnoballroombemorethantwiceaslongasitsnarrowestdimension.建议宴会厅的长度不应大于最窄处宽度的两倍。8a-1.11Theminimumceilingheightforballroomsof5,000squarefeet(464m)andbelowshallbetwelvefeet(3.6m)atoperablepartitions,increasingtonotlessthanfourteenfeet(4.2m)withinceilingcoffers.Theminimumceilingheightsforballroomsover6,000squarefeet(557m)areasfollows:希尔顿酒店设计和施工标准4叶予舜1/29/201210:55:04PM464平方米或更小的宴会厅的天花板最低高度在开闭式隔墙处应为3.6米,在镶板处不应低于4.2米。超过557平方米的宴会厅的天花板最低高度详细要求如下表:Area区域FinishedCeilingHeight竣工天花板高度ChandelierClearance/PartitionHeight吊灯净空/隔墙高度Upto12,000sq.ft(1114m)≤1114平方米20‘min.(6m)最低为6米18‘min.(5.4m)最低为5.4米12,000–28,000sq.ft(1114m–2601m)24‘(7.3m)22‘(6.7m)1114平方米–2601平方米7.3米6.7米28,000–35,000sq.ft(2601m–3251m)26‘(7.9m)24‘(7.3m)2601平方米–3251平方米7.9米7.3米35,000–45,000sq.ft(3251m–4180m)28‘(8.5m)26‘(7.9m)3251平方米–4180平方米8.5米7.9米8a-1.12Structuralcolumnsandoperablepartitionstackingmaynotprotrudemorethan1‘-6‖(0.4m)intotheballroomorbanquetroomatanypoint.结构柱和开闭式隔墙在任何一点伸入宴会厅或宴会间的凸出长度不得超过0.4米。8a-1.13AllpermanentwallssurroundingtheballroomshallextendtotheundersideofthestructureaboveandshallhaveaminimumacousticalratingofSTC-55.宴会厅所有永久性围墙应延伸至上方结构的底部,且隔声等级不得低于STC-55。8a-1.14Alloperablepartitionsmustbe,top-supportedwithdrop-downfloorsealsandhavealaboratorySTCof52minimumandfieldtestNIC42.Apermanent希尔顿酒店设计和施工标准5叶予舜1/29/201210:55:04PMacousticalseparationhavingaratingofnotlessthanSTC-55mustbeinstalledaboveeachoperablepartitionandextendedtotheundersideofthestructureabove.Sealallwiringandpipingpenetrations.Ductworkmaynotcrosssubdivisions.Providehardsurfaced,flushwallswhereoperablepartitionsterminatetoensureproperbeddingofjointseal.Providepocketdoorsforalloperablepartitions.所有开闭式隔墙的实验室隔声等级最低为STC52,现场检测NIC数据为42,其顶部由下落式地面密封条支撑。永久性的隔音材料应安装在每面开闭式间壁上面,并与地面建筑底部相连,隔声等级不应低于STC55。密封所有线路和管道贯穿件。管道系统不可穿过分区。开闭式隔墙终止处应采用硬表面、平整的墙面,以保证密接处形成合适垫层。所有开闭式隔墙应安装隐藏式移门。a)Ceiling-hung,manually-operatedpartitionsfromOperatorapprovedmanufacturer(partitionsover5.0mheightmayrequireelectricoperatinggear);经营者认可厂家提供的手动的吊顶隔墙(高度超过5米的隔墙应安装电动启闭门装置);b)Minimumsoundreduction50dbinstalled;安装后至少可降低50分贝的噪音;c)Partitionsfoldedinpermanentwallpocketswhennotinuse;当不使用时,隔墙可合拢在永久性墙壁内的梁座中;d)BaffleaboveceilingtracksinductspaceforaneffectivesoundsealbetweendivisionsoftheFunctionroom.Sealallwiringandpipingpenetrations.Ductworkmaynotcrosssubdivisionswithoutadequatesoundattenuation.Providehardsurfaced,flushwallswhereoperablepartitionsterminatetoensureproperbeddingofjointseal.在管道空间的吊顶轨上使用隔音板,以便在多功能厅分区之间有效隔音。密封所有线路希尔顿酒店设计和施工标准6叶予舜1/29/201210:55:04PM和管道贯穿件。如果没有足够的消音措施,管道系统不可穿过子分区。开闭式隔墙终止处应采用硬表面、平整的墙面,以保证密接处形成合适垫层。8a-1.15Provideapositivebulb-sealtypemechanicalclosure(hingedclosurenotacceptable)withminimum250lbs.pressure.Providesufficientstructuralsupportinabuttingwallstocompensateforthisrequirement.采用正压球型封条作为机械密封措施(不得使用铰链式密封),至少能承受250磅的压力。在相邻墙面上提供足够的结构支撑予以加强。8a-1.16Providerecessedmountingbracketsforsuspendedexhibitsorspeciallighting.为悬挂的展示品或特殊灯具提供嵌入式安装支架。8a-1.17Providestorageroomequalto10%ofthetotalballroomarea.设置相当于10%的宴会厅总面积大小的储藏室。8a-2.00DOORS,WINDOWSandHARDWARE8a-2.00门、窗和五金件8a-2.01Ballroomentrancedoorsmustbepaireddoors,notlessthan3‘-0‖wide(0.9m)and7‘-0‖high(2.1
本文标题:酒店管理会所 酒店设计标准8会议设施
链接地址:https://www.777doc.com/doc-914913 .html