您好,欢迎访问三七文档
编号:TS-H-L2-0*唐山西郊热电厂二期扩建工程电气专业监理细则(讨论稿)批准:审核:编制:山西建通电力工程建设监理有限公司唐山西郊监理部二00三年九月十一日唐山西郊热电厂二期工程电气专业监理细则-2-目录1.电气专业二期扩建工程概况1.1概述·····················1.2电气主接线··················1.3设备型号及规格················1.4导体型号及规格················1.5高压厂用电接线················1.6低压厂用电接线················1.7厂用配电装置布置及设备型号··········1.8事故保安电源及交流不停电电源·········1.9电气设备的布置位置··············1.10直流系统概述················1.11二次线及继电保护配置·············1.12过电压保护及接地设计·············1.13照明及检修网络················1.14全厂电缆设施·················2.专业监理细则编制依据2.1编制依据····················3.专业监理范围及内容3.1专业监理范围··················3.2专业监理内容··················4.专业监理工作控制目标4.1总体控制目标··················4.1.1质量控制目标·················4.1.2进度控制目标·················4.1.3投资控制目标·················4.1.4安全控制目标·················4.2机组达标投产专业监理控制目标··········4.3火电优质工程专业监理控制目标··········唐山西郊热电厂二期工程电气专业监理细则-3-5.电气专业监理主要工作流程5.1单位工程质量控制程序·············5.2隐蔽工程、分项工程质量检验程序········5.3建筑安装材料购配件签认程序··········5.4工程设备开箱检验程序·············5.5单位工程开工申报程序·············5.6设计变更程序·················5.7工程洽商程序·················(以上7项内容复制不全,详细参阅监理规划)5.8发电机电气与引出线安装监理工作流程·······5.9变压器安装监理工作流程·············5.10SF6断路器安装监理工作流程··········5.11动力、控制及保护盘、柜安装监理工作流程····5.12电动机检查接线监理工作流程···········5.13蓄电池安装监理工作流程·············5.14电缆敷设监理工作流程·············6.专业监理工作实施内容6.1监理质量控制实施内容···············6.1.1高低压配电盘就位前质量监理工作内容·······6.1.2开关柜母线安装质量监理工作内容·········6.1.3小车柜安装质量监理工作内容···········6.1.4配电盘柜安装质量监理工作内容··········6.1.5控制、保护和直流屏安装质量监理工作内容·····6.1.6互感器安装质量监理工作内容···········6.1.7隔离开关安装质量监理工作内容··········6.1.8避雷器安装质量监理工作内容···········6.1.9电动机检查接线监理工作内容···········6.1.10发电机电气与引出线安装监理工作内容······6.1.11二次回路接线质量监理工作内容··········6.1.12蓄电池安装质量监理工作内容···········唐山西郊热电厂二期工程电气专业监理细则-4-6.1.13电缆敷设质量监理工作内容···········6.1.14接地装置安装质量监理工作内容·········6.1.15SF6断路器安装质量监理工作内容·······6.1.16电力变压器安装质量监理工作内容········6.2专业监理安全控制工作内容6.2.1施工用电监理安全控制工作内容··········6.2.2停送电作业监理安全控制工作内容·········6.2.3电气设备安装安全监理工作内容··········6.2.3.1变压器安装安全监理工作内容··········6.2.3.2变压器干燥安全监理工作内容··········6.2.3.3发电机及电动机安装安全监理工作内容······6.2.3.4断路器及互感器安装安全监理工作内容······6.2.3.5蓄电池安装安全监理工作内容··········6.2.3.6盘、柜安装安全监理工作内容··········6.2.3.7其它电气设备安装安全监理工作内容·······6.2.3.8母线安装安全监理工作内容···········6.2.3.9电缆工程施工安全监理工作内容·········6.2.3.10电气调整试验安全监理工作要点········6.2.3.11二次回路传动试验安全监理工作要点······6.2.3.12带电及起动时安全监理工作要点········6.3设备开箱验收及保管监理工作内容7.附件7.1单位工程一览表(附件一)··7.2开工报审及施工组织设计/施工技术措········施报审目录(附件二)···········7.3需报验的电气用原材料、半成品、构配件清单及监理具体要求(附件三、不限于此)···········7.4四级验收项目及监理见证范围一览表(附件四)···7.5电气专业调试监理实施细则(附件五)·········(附件中所列内容需与建设方及施工方协商确定)·····唐山西郊热电厂二期工程电气专业监理细则-5-1、电气专业二期扩建工程概况1.1概述唐山西郊热电厂二期扩建工程建设规模为1×200MW抽凝式汽轮发电机组,配置1×670t/h超高压一次中间再热煤粉炉。并留有扩建余地。1.2电气主接线在唐山西郊热电厂110KV配电装置南侧新建一个220KV出线间隔,以220KV电压接入系统,以一回220KV线路经规划的丰南变电所接入宋加营变电所,变电所至厂区25km。本期一台机组以发电机-变压器-线路组接入,线路采用架空输电线路。因西郊电厂远景终期有四回出线,所以本期配电装置留有双母线布置的余地。1.3设备选择主变压器选用双线圈无励磁调压强迫油循环风冷变压器。其规范为:(西安西变)1.3.1型式:三相双绕组,无载调压变压器。型号:SFP-240000/220额定容量:240MVA(绕组温升60K时)。额定电压:高压侧:220kV低压侧:18kV额定电压比:242±2×2.5%/18kV额定频率:50Hz唐山西郊热电厂二期工程电气专业监理细则-6-额定电流:高压侧:572.6A低压侧:7698.0A短路阻抗:14%联接组标号:YN,d11冷却方式:强油风冷(ODAF);台数:1台1.3.2高启变(西安西变)为三卷分裂式变压器并带有平衡绕组。型式:三相分裂变(带平衡绕组)有载调压变压器。型号:SFFZ-40000/110额定容量:40MVA/25-25MVA(绕组温升60K时)。额定电压:高压侧:110kV低压侧:6.3kV额定电压比:115±8x1.25%/6.3-6.3kV额定频率:50Hz额定电流:高压侧:201A低压侧:2291A唐山西郊热电厂二期工程电气专业监理细则-7-短路阻抗:16.5%联接组标号:YN,yn0,yn0,d冷却方式:ONAN/ONAF台数:1台1.3.3高压厂用工作变压器(西安西变)型式:三相油浸风冷,低压幅向分裂变无励磁调压,户外式。主要技术参数额定电压:高压侧:18kV低压侧:6.3kV分接范围:182×2.5%/6.3—6.3kV空载额定变比:18/6.3—6.3kV额定容量40MVA/(25—25MVA)额定频率:50Hz极性:负极性短路阻抗:16.5%(在额定电压和频率下,温度为75℃时,对分裂变压器是以高压绕组额定容量为基准的半穿越短路阻抗)(短路阻抗误差不超过±5%)联结组标号:D,yn1,yn1端子连接方式:高压侧:18kV分相封闭母线。低压侧:6.3kV封闭母线。低压侧中性点经电阻接地,中性点电流不大于20A.绕组绝缘耐热等级:A级1.3.4220KV断路器选用(山东泰开)LW30-252/T3150-50(弹簧机构)型,工频耐压(1min)断口及对地均为460kv,额定电流为3150A,额定开断电流40kA;唐山西郊热电厂二期工程电气专业监理细则-8-1.3.5110KV断路器选用(山东泰开)LW30-126/T3150弹簧机构型,工频耐压(1min)断口为265kV,对地为230kv,额定电流为3150A,额定开断电流31.5kA;1.3.6220KV隔离开关选用(平高电气厂)GW7-220DW/2500A-50KA型,额定电流2000A;工频耐压(1min)为395kV,额定热稳定电流40kA(3S),额定动稳定电流125kA;1.3.7110KV隔离开关选用(西安高压开关厂)GW4-110W/1250A额定电流1250A;工频耐压(1min)为230kV,额定热稳定40kA(4S),额定动稳定电流100kA;1.3.8发电机选用山东济南发电设备厂生产的WX23Z-109型发电机,额定功率200MW,额定容量235.3MVA,功率因素0.85(滞后),额定电压18KV,额定电流7547.1A,冷却方式为转子直接冷却,定子间接冷却,励磁方式为静态励磁,空载励磁电流为496.7A,空载励磁电压为91.9V,流为1252.6A,满载励磁电压为302.9V;1.3.9220KV级电流互感器选用保变天威LB10-220W3型互感器,额定一次电流1250A,二次电流为1A,级次组合为0.2S/0.5S/5P/5P/5P/5P,额定二次容量为20VA及40VA,额定热稳定50kA(3S)。1.3.10110KV级电流互感器选用保变天威LCWB6-110W3型互感器,额定一次电流600A,二次电流为5A,1A,级次组合为0.2S/5P/5P/5P,额定二次容量为80VA及40VA,额定热稳定50kA(3S)。1.3.11220KV级电压互感器选用西安电容器厂生产的TYD-220/√3-0.005H型电容式电压互感器,工频一分钟干式:460kV,湿式:460kV,雷电冲击(1.2/50μS)(峰值):1050kV,瞬变响应特性小于短路前5%,电容偏差:不超过额定值的-3%或+4%,1.4导体选择唐山西郊热电厂二期工程电气专业监理细则-9-1.4.1发电机回路的主母线采用离相封闭母线,型号*******;主变220KV导线采用钢芯铝绞线,型号2XLGJ-300;高压备用变高压侧采用钢芯铝绞线,型号LGJ-240;低压侧通过共箱封闭母线与6KV工作段备用进线开关柜连接;高压厂用变压器的高压侧经厂用分支离相封闭线与发电机-主变封母连接,低压侧通过共箱封闭母线与6KV工作段工作进线开关柜连接。1.4.26KV电缆选用铜芯、交联聚乙稀绝缘、聚氯乙烯护套难燃性电缆,其热稳定最小截面铜芯为95mm2。低压动力电缆选用聚氯乙烯绝缘、聚氯乙烯护套电缆,绝缘水平1KV。控制电缆采用铜芯,绝缘水平600V/1000V。计算机用电缆及部分控制电缆采用屏蔽电缆。1.5高压厂用电接线方案本工程设二段6KV工作母线,老厂的7台变压器备用电源接至本期6KV配电段。在起动期间,6KV母线由高备变供电,起动完毕后,通过主变高压侧断路器同期并网后,6KV供电由高备变切换为高厂变。低压变压器和容量大于200KW的电动机由6KV配电装置供电,真空断路器用于;带熔断器的真空接触器(FC)用于容量为1250KVA以下的低压变压器回路和容量小于1000KW及以下的电动机回路。6KV工作段布置在主厂房BC列0m层
本文标题:电气细则
链接地址:https://www.777doc.com/doc-130610 .html