您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 工程监理 > 龙岗龙东临时用电方案
深圳市龙岗区龙岗街道龙东社区源盛居民小组综合整治工程临时用电安全施工方案编制:审核:审批:深圳市粤华建筑工程有限公司龙岗龙东源盛项目部二0一0年八月2目录一、编制依据················································································3二、工程慨况················································································4第一节工程基本概况································································4第二节工程施工环境概况··························································4(一)场地气象、水文地质条件····················································4第三节工程质量和工期要求························································5三施工临时用电方案···································································6(一)、用电计划·······································································6(二)、用电搭接方案·································································7(三)、配电箱、开关箱设计························································8(四)、配线设计·····································································11四临时用电安全技术措施···························································13(一)、电工及用电人员····························································13(二)、配电箱与开关箱····························································14(三)、电缆敷设·····································································16(四)、照明用电·····································································18(五)、安全技术措施·······························································20(六)、触电事故应急措施·························································223一、编制依据1、北方设计研究院设计的《深圳市龙岗区龙岗街道龙东社区源盛居民小组综合整治工程》施工图。2、现行国家有关施工现场临时用电施工及验收规范、技术标准、工程质量评定标准及操作规程。3、ISO9001:2008版质量管理体系标准;ISO14001环境管理体系标准;OHSAS18001职业健康管理体系标准。4、我公司施工质量保证体系及安全保证体系的相关文件要求和经验资料。5、我公司的《项目管理手册》和《项目管理实施细则》。6、规范、规程《建筑施工安全检查标准》(JGJ59-99)《建筑机械使用安全技术规程》(JGJ33-2001)《建筑工程施工现场供用电安全规范》(GB50194-93)《施工现场临时用电安全技术规范》(JGJ46-88)《中华人民共和国工程建设标准强制性条文》(各相关部分)7、参考资料:《建筑施工计算手册》江正荣著中国建筑工业出版社《建筑施工手册》第四版中国建筑工业出版社4二、工程慨况第一节工程基本概况龙岗街道龙东社区源盛居民小组综合整治项目属于深圳市龙岗区龙东社区,是组团规则当中的东部工业组团规划片区。地块东临大埔二路,南临惠盐高速公路,西临龙南路,北临龙湖路。整治面积为10.9公顷(含市政道路面积)。源盛村建设是村民自发进行的,因此建筑布局松散,整体环境较差。用地内设有较大的广场,西南部分、中北部有工业厂房。整治区内部主要交通道路为区内主干道,现状路面质量关工,通行能力差,村落内没有专门的停车场,车辆的停放一般在路道边和住宅旁。区内现状存在部分闲置用地,杂草从生,生活垃圾与建筑垃圾随处可见,缺乏道路绿化,景观环境现状较差,整个片区内没有统一规划管理,绿化率严重不足,空气自净能力较差;村内消防设施不能满足要求,需要进行整治。排水不成系统,雨污合流,缺少日常检查与维护;电力电信线路随意架空敷设,照明系统不完善。现状主要出入口已设置岗亭道闸,但未设置监控等设施,外来人员可随意出入本社区,安全隐患较大。第二节工程施工环境概况(一)场地气象、水文地质条件1场地气象条件拟建场地为深圳地区,属于亚热带海洋性季风气候,气候温和,雨量充沛且多为台风雨,夏季高温多雨,冬季低温干旱。多年平均气温22.4℃,多年平均湿度79%,常年主导风向为东南风和东北风,多年平均风速为3.2m/s,最大风速为12级。每年4~9月为雨季,年平均降雨量为1933.3mm,日最大5暴雨量385.8mm,多年平均蒸发量1755.4mm。2、路基工程地质拟建道路均为改造道路,原有道路基本建筑在山坡地,地质良好。3、地理环境本工程施工范围全部在村民居住区内,所有改造道路为村内居民的主要出入、运输道路,施工期要保证正常交通,只能分段施工。第三节工程质量和工期要求工程质量要求标准:按国家验收标准达到合格,争创“优良”。工期要求:要求2010年8月开工;2011年1月完工;工期:合同工期120个日历天。考虑到春节因素,计划工期150日历天。本工程必须有科学合理的施工组织方案,加强施工期间对工期的控制和管理,在保证工程质量、安全文明施工的前提下按期或提前完成施工任务。6三施工临时用电方案(一)、用电计划1、生活办公用电:本工程办公用员工生活区均租用住宅区居民房,不必考虑供用电。现场只设临时仓库及保安用房,生活用电不超过2KW/h。2、施工用电:用电机械设备如下:空压机用电量为3KW/h。(破除路面用)混凝土振捣器4台计5KW/h。(浇筑道路路面砼、建构筑物砼、管道基础各检查井砼用)电焊机5KW/h。(钢筋工程)切割机3KW/h。(路面切缝)砂浆搅拌机2台:6KW/h潜水泵3KW/h。夜间照明2KW/h。钢筋加工机械:5KW/h。其他小型机械设备:3KW/h合计:35KW/h。以上机械设备不在同一地点同一时间使用,最大用电使用量可按35×0.6=21KW/h计算。加现场设施照明,最大用电量不超过23KW/h。最少在三处不同地点搭接,每处用电量不超过8KW/h。根据居民区内现有供电情况,完全有能力满足供应。7(二)、用电搭接方案由于用电时小,经与龙东社区源盛村股份有限公司联系,同意在居民区内分别搭接电源,不会影响到居民正常用电。具体搭接方式如下:1、根据施工区施工位置,就近在股份有限公司指定的配电柜旁挂一个二级配电箱,设总用电控制开关,由二级配电箱引出一条主蕊线为25mm2的三相五线电缆架空敷设至施工现场,在现场设置三级配电箱,箱内设四个控制开关,分别供机械设备和照明使用,现场空压机、电焊机、振动器、水泵等设备应分别设立四级开关箱或开关板,严格执行三级配电两级保护原则。按一机一箱一开关一漏电的规范要求设置。2、本工程建筑物(厕所)构筑物(垃圾房、挡墙、围墙等)可在两处布置固定三级配电箱,由于道路施工线路长2千余米,二、三级配电箱必须流动搭接,每处搭接线路距二级配电箱距离不得大于150m。配电系统图如下:三级配电系统示意图居民村内配电柜三级配电箱(施工分配电箱)开关箱开关箱开关箱开关箱开关箱开关箱二级配电箱(施工总配电箱)8(三)、配电箱、开关箱设计(1)、在居民区内最接近的地方选择一个可提供12.04KW/h的供电电源并单独设置一个二级配电箱作为总配电箱以便于安全控制总配电箱电器接线图:NDKDZRCDDK1DK2DZ2DZ2PE端子板NNNLPELPEL注:总配电箱构成情况为:电源进线经隔离开关DK控制,并以低压自动空气开关DZ(为四级型)或熔断器作为短路、过载保护和以漏电保护器RCD作总漏电保护,若RCD具有过载和短路保护功能时,则可不设DZ或熔断器。配电出线有两路线每路均设低压自动开关(DZ1,DZ2)或熔断器作短路和过载保护,用低压隔离开关(DK1,DK2)控制负荷。动力与照明应分开出线。电源相线N为3根,经专用端子板作重复接地。(2)、在施工现场选择一处对厕所、垃圾房和钢筋制作场都方便接线的地点建立一个固定三级配电箱(分配电箱),分配电箱电器接线图:○○○○○○○○○○○9NPELPELNPEL1N注:分配电箱单相用于照明和单相用电设备,三相用于电动机、电焊机等动力配电,电源由总配电箱引来,设置低压总隔离开关,用低压自动空气开关或或熔断器作为短路、过载保护。出线按实际要求设多路输出,每路出线均设分路隔离开关,并用低压自动空气开关作短路、过载保护。电源相线为三根。(3)施工现场用电严格按照一机一箱一开关一漏电的规范要求设置。每台设置应有专用配电开关箱,开关箱内的开关电器在任何情况下,都可使用电设备与电源隔离。开关箱电器接线图:NPEPELL1NPEPEL1N三箱动力开关箱单箱照明开关箱DK2N端子板DK1FQ2DKFQ1PE端子板FQPE端子板○○○○○○DKNPE○○RCDDKRCD○○10注:开关箱为用电设备的控制装置,接线按用电设备负荷的类别(三相或单相)确定,电源由分配电箱引来,设隔离开关和漏电保护器接通、分断电路和做短路、过载与漏电保护。2、蓝球场、池塘挡墙、围墙在相互接近范围,可在三者之间选择一个位置布置分配电箱,其用电设备不需设置钢筋制作场所,其他用电设备基本与厕所和垃圾房相同,分配电箱和开关箱与以上接线图相同。3、道路改造施工由于线路长采用流动式总配电箱和分配电箱。总配电箱、分配电箱和开关箱与以上接线图相同。完成一段布置一段,根据现场实际情况每条道路或两条道路转移一次。4、配电箱设置要求:(1)、总配电箱应靠近电源设置,分配电箱应设置在用电设备和负荷集中的地方。分配电箱与开关箱的距离不得超过30m,开关箱与其控制的固定式用电设备的水平距离不宜超过3m。(2)、配电箱、开关箱必须采用铁板或优质绝缘材料制作。箱内连接线应采用绝缘导线,接头不得松动,不得有外露带电部分。(3)、配电箱、开关箱内的电器必须可靠完好,不准使用破损、不合格的电器。严格实行:“一机一闸”制,严禁一个开关箱直接控制二台以上的用电设备(含插座)。(4)、开关箱内漏电保护器额定漏电动作的电流应≤30mA,时间应<0.1S。(5)、漏电保护器必须按产品说明书安装,连续使用一个月和搁置已久又重新使用的漏电保护器,必须认真检查其特性,发现问题应及时修理或更换。11(四)、配线设计1、厕所和垃圾房在同一范围内,用电设备如下:电焊机5KW/h。(钢筋工程)砂浆搅拌机1台:3KW/h钢筋加工机械:切断机一台3KW/h、弯曲机一台2KW/h,合计5KW/h。振捣设备:2.2KW/h。其他小型机械设备:1.5KW/h夜间照明0.5KW/h。以上合计17.2KW/h。但不会在同一时间内使用,使用系数按0.7计算,则用电量为:17.2KW/h×0.7=12.04K
本文标题:龙岗龙东临时用电方案
链接地址:https://www.777doc.com/doc-1929256 .html