您好,欢迎访问三七文档
当前位置:首页 > 办公文档 > 其它办公文档 > 卫东变66kV变电站综合自动化系统专用技术规范-
1卫东66千伏变电站计算机监控系统专用技术规范凌海供电有限责任公司2015.11.22目次1标准技术参数··············································································································32项目需求部分··············································································································92.1货物需求及供货范围一览表··························································································92.2必备的备品备件、专用工具和仪器仪表供货表····································································142.3图纸资料提交单位···································································································142.4工程概况··············································································································142.5使用条件··············································································································142.6项目单位技术差异表·································································································152.7一次、二次及土建接口要求(适用扩建工程)····································································153投标人响应部分··········································································································153.1投标人技术偏差表···································································································153.2销售及运行业绩表···································································································163.3推荐的备品备件、专用工具和仪器仪表供货·······································································163.4最终用户的使用情况证明····························································································163.5投标人提供的试验检测报告表······················································································163.6投标人提供的鉴定证书表····························································································1631标准技术参数投标人应认真逐项填写标准技术参数表(见表1~表17)中投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。如有差异,请填写表24投标人技术偏差表。表1110kV(66kV)变电站计算机监控系统标准技术参数表序号参数名称单位标准参数值投标人保证值1*电流量、电压量测量误差%≤0.2(投标人填写)2*有功功率、无功功率测量误差%≤0.5(投标人填写)3*电网频率测量误差Hz≤0.01(投标人填写)4模拟量越死区传送整定最小值≥0.1%(额定值),并逐点可调(投标人填写)5*事件顺序记录分辨率(SOE)站控层ms≤2(投标人填写)间隔层测控单元ms≤1(投标人填写)6模拟量越死区传送时间(至站控层)s≤2(投标人填写)7*状态量变位传送时间(至站控层)s≤1(投标人填写)8*模拟信息响应时间(从I/O输入端至远动通信装置出口)s≤3(投标人填写)9*状态量变化响应时间(从I/O输入端至远动通信装置出口)s≤2(投标人填写)10控制执行命令从生成到输出的时间s≤1(投标人填写)11*控制操作正确率%100(投标人填写)12站控层平均无故障间隔时间(MTBF)h≥20000(投标人填写)13*间隔级测控单元平均无故障间隔时间h≥30000(投标人填写)14站控层主机兼操作员工作站的CPU平均负荷率正常时(任意30min内)%≤30(投标人填写)电力系统故障(10s内)%≤50(投标人填写)15网络平均负荷率正常时(任意30min内)%≤20(投标人填写)电力系统故障(10s内)%≤40(投标人填写)16*模数转换分辨率bit≥14(投标人填写)17*实时数据库容量模拟量点≥2000(投标人填写)状态量点≥5000(投标人填写)遥控点≥500(投标人填写)计算量点≥2000(投标人填写)18*历史数据库存储容量历史曲线采样间隔min1~30,可调(投标人填写)历史趋势曲线,日报,月报,年报存储时间年≥2(投标人填写)历史趋势曲线数量条≥300(投标人填写)表235kV及以下备用电源自动投入装置标准技术参数表4序号参数名称单位标准参数值投标人保证值1*电流定值误差%≤3(投标人填写)2*电压定值误差%≤3(投标人填写)3*时限定值误差ms≤40(投标人填写)4*电流量测量误差%≤0.2(投标人填写)表2(续)序号参数名称单位标准参数值投标人保证值5*遥控命令输出正确率%100(投标人填写)6*事件顺序记录分辨率(SOE)ms≤2(投标人填写)7交流电压回路功率损耗(每相)VA≤1(投标人填写)8交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)9装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)10跳闸触点容量长期允许通过电流≥5A;触点断开容量为≥50W(投标人填写)11其他触点容量长期允许通过电流≥2A;触点断开容量为≥30W(投标人填写)表335kV及以下变压器(主后合一)保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*差动速断时限定值误差ms≤30(2倍整定值)(投标人填写)2*比率差动时限定值误差ms≤40(2倍整定值)(投标人填写)3*电流定值误差%≤3(投标人填写)4*制动系数定值误差%≤3(投标人填写)5*后备保护电流定值误差%≤3(投标人填写)6*后备保护电压定值误差%≤3(投标人填写)7*后备保护时限定值误差%≤3(投标人填写)8*后备保护方向元件动作范围边界误差≤5°(投标人填写)9交流电压回路功率损耗(每相)VA≤1(投标人填写)10交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)11装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)表435kV及以下变压器差动保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*差动速断时限定值误差ms≤30(2倍整定值)(投标人填写)2*比率差动时限定值误差ms≤40(2倍整定值)(投标人填写)5序号参数名称单位标准参数值投标人保证值3*电流定值误差%≤3(投标人填写)4*制动系数定值误差%≤3(投标人填写)5交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)6装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)表535kV及以下变压器后备保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*后备保护电流定值误差%≤3(投标人填写)2*后备保护电压定值误差%≤3(投标人填写)3*后备保护时限定值误差%≤3(投标人填写)4*后备保护方向元件动作范围边界误差≤5°(投标人填写)5*电流量、电压量测量误差%≤0.2(投标人填写)6*有功功率、无功功率测量误差%≤0.5(投标人填写)7*电网频率测量误差Hz≤0.02(投标人填写)8*遥控命令输出正确率100%(投标人填写)9*事件顺序记录分辨率(SOE)ms≤2(投标人填写)10交流电压回路功率损耗(每相)VA≤1(投标人填写)11交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)12装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)表635kV及以下非电量保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*非电量启动功率W>5(投标人填写)2*启动电压直流操作电压的55%~70%(投标人填写)3*动作时间ms10~35(额定直流电源电压下)(投标人填写)表735kV及以下电抗器保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*电流定值误差%≤3(投标人填写)2*电压定值误差%≤3(投标人填写)3*时限定值误差ms≤40(投标人填写)4*电流量、电压量测量误差%≤0.2(投标人填写)5*有功功率、无功功率测量误差%≤0.5(投标人填写)6*电网频率测量误差Hz≤0.02(投标人填写)7*遥控命令输出正确率%100(投标人填写)8*事件顺序记录分辨率(SOE)ms≤2(投标人填写)6序号参数名称单位标准参数值投标人保证值9交流电压回路功率损耗(每相)VA≤1(投标人填写)10交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)11装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)12跳闸触点容量长期允许通过电流≥5A;触点断开容量为≥50W(投标人填写)13其他触点容量长期允许通过电流≥2A;触点断开容量为≥30W(投标人填写)表835kV及以下电容器保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*电流定值误差%≤3(投标人填写)2*电压定值误差%≤3(投标人填写)3*时限定值误差ms≤40(投标人填写)4*电流量、电压量测量误差%≤0.2(投标人填写)5*有功功率、无功功率测量误差%≤0.5(投标人填写)6*电网频率测量误差Hz≤0.02(投标人填写)7*遥控命令输出正确率%100(投标人填写)8*事件顺序记录分辨率(SOE)ms≤2(投标人填写)9交流电压回路功率损耗(每相)VA≤1(投标人填写)10交流电流回路功率损耗(每相)VA≤0.5(IN=1A)≤1(IN=5A)(投标人填写)11装置直流消耗W≤50(工作时)≤80(动作时)(投标人填写)12跳闸触点容量长期允许通过电流≥5A;触点断开容量为≥50W(投标人填写)13其他触点容量长期允许通过电流≥2A;触点断开容量为≥30W(投标人填写)表935kV及以下电压并列/电压切换装置标准技术参数表序号参数名称单位标准参数值投标人保证值1装置直流消耗W≤5(工作时)≤8(动作时)(投标人填写)2触点容量长期允许通过电流≥5A;触点断开容量为≥5
本文标题:卫东变66kV变电站综合自动化系统专用技术规范-
链接地址:https://www.777doc.com/doc-2599579 .html