您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 工程监理 > 冀东石油家园二次结构方案
冀东石油家园住宅小区1标段1#、2#、3#楼及车库二次结构方案1二次结构方案目录一、编制依据································································2二、工程概况································································2三、施工部署································································2四、加气砼砌块施工····················································3五、植筋施工方法························································7六、材料与质量控制····················································11七、季节性施工·····························································18八、质量保证措施及质量通病的分析与控制············19九、成品保护································································20十、安全文明施工措施················································21冀东石油家园住宅小区1标段1#、2#、3#楼及车库二次结构方案21、编制依据1.1工程施工图纸(1)1#楼结构施工图纸;(2)2#楼结构施工图纸;(3)3#楼结构施工图纸(4)1#楼建筑施工图纸;(5)2#楼建筑施工图纸;(6)3#楼建筑施工图纸(7)1区地下及商业建筑专业施工图纸;(8)1区基础及地下人防部分结构施工图纸;(9)1区地下二层~地上三层部分结构专业施工图纸;(10)1区地下及商业建筑专业施工图纸。1.2工程应用的主要规程、规范、标准(1)混凝土结构加固技术规范;(2)砌体工程施工质量验收规范;(3)建筑机械使用安全技术规程;(4)施工现场临时用电安全技术规范;(5)砼结构工程施工质量验收规范;(6)砌体工程施工质量验收规范;(7)建筑工程施工质量验收统一标准;(8)灰渣混凝土空心隔墙板;(9)唐山市住宅工程质量通病防治措施。1.3工程应用的主要图集(1)建筑物抗震构造详图;(2)加气砼砌块墙。2工程概况冀东石油家园住宅小区1标段1#、2#、3#楼及地下车库工程;工程建设地点:唐山光明北路冀东石油家园住宅小区;属于框剪结构;1#、2#楼地下3层地上31/28层,3#楼地下3层,地上29/26层,标准层层高均为2.9m。3施工部署3.1技术准备(1)施工前必须认真核对图纸,了解各部位的材料选择、做法和技术要求。(2)基础、主体结构验收合格后方可进行砌体工程施工。(3)做好书面的技术及安全交底,施工前由施工员进行现场交底。(4)砌体材料的复试和砂浆配合比确定工作。3.2材料、机具准备(1)地上外墙除剪力墙外,本工程外墙采用同剪力墙厚加气砼砌块砌筑,框架部分问200厚加气砼砌块砌筑,强度不小于2.8MPa。(2)地上内隔墙:防火分区间隔墙采用200厚加气砼砌块砌筑,轻质隔墙采用90厚增强水泥空心条板,管井及楼梯间隔墙采用100厚加气砼砌块砌筑,其它隔墙采用200厚加气砼砌块砌筑,剪力墙间的填充墙同墙厚,强度不小于2.8MPa,卫生间等有水房间上述墙体应做砼槛墙,宽度同墙宽,高200mm。(3)地下室内隔墙:防火分区间隔墙采用200厚加气砼砌块砌筑;其他隔墙除特殊情况外,采用200厚加气砼砌块,强度不小于2.8MPa。储藏间轻质隔墙采用90厚增强水泥空心条板。(4)加气砼砌块墙体水平方向转折,相交处均应设构造柱。当墙体长度大于5m时,在4m部位加设构造柱。(5)砌筑砂浆:砌筑砂浆采用现拌砂浆,地上内外墙采用M5的混合砂浆;地下墙体采用M5的水泥砂浆。冀东石油家园住宅小区1标段1#、2#、3#楼及车库二次结构方案3(6)水泥:1、水泥采用32.5级的普通硅酸盐水泥或矿渣硅酸盐水泥。2、水泥进场使用前,应分批对其强度、凝结时间、安定性进行复试。3、当在使用中对水泥的质量有怀疑或水泥出厂超时三个月时,应复查试验,并按其结果使用。4、不同品种的水泥不得混合使用。5、砼:构造柱、圈梁、过梁砼设计强度等级为C20.6、其它材料:其它材料预埋件、刷防腐剂的木砖等。7、根据施工期间的工程量、施工进度,确定材料的数量及进场时间,有专人负责,确保材料按时进场,并妥善保管。8、材料进场后堆放整齐,上部覆盖严密,下部垫起架空,防止日晒雨淋。(7)施工机具准备:主要施工机具:砂浆搅拌机、手推车、大铲、手锯、托线板、线坠、钢卷尺、灰槽、小水桶、笤帚、2米靠尺等。3.3现场准备1、对进场的砌块型号、规格、数量、质量、和堆放位置、次序进行检查、验收、能满足施工要求。2、所需机具设备准备就绪并已安装到位。3、放好砌块墙身位置线、门窗洞口等位置线和建筑50标高线或1米标高线,经验线合格后方可施工。4、立皮数杆:宜采用30*40木料制作,皮数杆上注明门窗洞口、木砖、拉结筋、圈梁等的尺寸标高。皮数杆宜在门窗和砌体转角处设立,一般距墙皮或墙角50毫米为宜。皮数杆应垂直、牢固、标高一致、经复核、办理预检手续。5、上道工序已经验收合格,并办好交接手续。6、根据最下面一皮砖的标高,拉通线检查,楼板结构或室内地坪出现偏差是应预先用1:2的水泥砂浆找平,如水平灰缝厚度超过20毫米,用C20细石砼找平。7、样板墙砌筑:在正式施工前,应先砌筑样板墙,经各方验收合格后,方可正式砌筑。4、加气砼砌块施工1、施工工艺流程:楼面清理墙体放线立皮数杆制备砌筑砂浆砌块排列铺砂浆砌块就位校正砌筑竖缝灌砂浆勾缝验收。2、施工要点:(1)加气砼砌块的砌筑面上应适量洒水,砌块施工时含水率应控制在15%以下。(2)放线:加气砼砌块砌筑前,应在楼面定出轴线位置,在柱、墙上标出标高线。(3)立皮数杆:在各转角处设立皮数杆,皮数杆间距不得超过15米。皮数杆上应注明门窗洞口、木砖、拉结筋、圈梁、过梁的尺寸标高。皮数杆应垂直、牢固、标高一致。(4)拌制砂浆:砂浆随伴随用,一般在3-4小时内用完,严禁用隔夜砂浆;砂浆具有一定的粘结性,良好的和易性和保水性,砂浆的稠度控制在70-80mm。(5)加气砼砌块砌筑墙体时,所有填充墙自结构板面上砌三皮蒸压灰砂浆砖,冀东石油家园住宅小区1标段1#、2#、3#楼及车库二次结构方案4卫生间等有防水要求的房间,房间四周除门洞外,做C20的砼翻边,其高度为200mm,厚度同墙厚。砼翻边处的楼板应在模板安装前,进行凿毛处理。所有管井的门口均做门槛,高度详见施工图。(6)根据各段墙身的细部尺寸,进行排砖撂底,使组砌方法合理,以便于操作。砌块排列尽量采用主规格砌块,减少品种,减少切割开封,以保证墙体良好的整体性。(7)加气砼砌块的砌筑方法可采用“铺灰灌浆法”。先在墙顶上铺摊砂浆,然后将砌块按砌筑位置摆放到砂浆层上,并与前一块砌块靠拢,留出不大于20mm的空隙。待砌完一皮砌块后,在空隙两旁安装上夹板,在砌块的灌浆槽内灌砂浆,直至灌满。等到砂浆开始硬化不流淌时,即可卸掉夹板。(8)加气砼砌块砌筑时应上下错缝搭接长度不小于砌块长的1/3。当不能满足要求时,应在水平灰缝中设置不大于500mm长度的2Φ6钢筋。(9)加气砼砌块墙的转角处,应使纵横墙的砌块相互搭接,隔皮砌块露端面。加气砼砌块墙的T字交接处,应使横墙砌块隔皮露端面,并做中于纵墙砌块。(10)每段内的砌块墙体应连续砌完,不留接茬。如必须留茬时,应留成斜茬,或门窗洞口侧边间断。(11)砌筑时,水平及垂直灰缝均应≤15mm,如砌块精确,灰缝应尽可能的减少。砂浆饱满度竖缝应≥85%,水平缝应≥90%。(12)穿越墙体的水管应严防渗水,穿墙附墙或埋入墙体内的铁件应做防锈处理。(13)砌体墙体沉实后(砌体砌筑并应至少间隔7天后)加气砼砌块填充墙墙长5米时强顶砌至板、梁附近后不易采用斜砌实心砖楔紧法而应在强顶放置一条通长高弹性材料(如泡沫胶联聚乙烯等)再用防腐木楔楔紧,墙长不小于5米时,强顶与梁板还应有拉结措施,具体做法详见图纸。(14)加气砼砌块墙体上不得留设脚手眼。(15)砌块在砌筑时要随吊、随靠,以保证墙体垂直、平整。(16)水电安装线槽施工,砌体施工完后,在预埋位置弹线,用切割机沿线切槽(切割前与土建相互协调好),预埋后用C15细石砼填实抹平,并应在槽面上加贴耐水玻纤网格布,防止开裂。(17)在砌体施工前,水电安装需将预留洞口的尺寸提前交给技术质量部,有技术质量部将之下发给工程部及砌体施工队伍,施工时按图施工。(18)加气砼砌块切锯钻孔、开槽、设预埋件等均应采用专用工具,不得用斧子瓦刀任意剔凿。(19)墙应在主体结构施工完毕后,宜由上而下砌筑,防止下层梁承受上层梁以上的荷载。(20)加气砼砌块与不同材料(如构造柱,门窗过梁等)的界面及接缝处,应采用专用砂浆增强玻纤网格布置在这些部位,以加强粘结性。砂浆可采用聚合物水泥砂浆,也可采用粉刷石膏。4.1构造柱、圈梁、抱框立柱、过梁、拉结筋施工1、构造柱、包框立柱、水平系梁、过梁、拉结筋的布置。(1)构造柱布置:A:墙体水平方向转折、相交处。B:当墙长大于5米时,在4米部位加设;当填充墙长度超过层高2倍也应在沿填充墙每隔4米处加设构造柱。冀东石油家园住宅小区1标段1#、2#、3#楼及车库二次结构方案5(2)抱框立柱的布置:门窗洞口两侧。(3)水平系梁的布置:墙高度超过4米时,在墙的大约中部每隔2米或门窗顶适当位置架钢筋砼水平系梁一道。(4)过梁布置:门窗洞口上部。(5)拉结筋布置:后砌填充墙与柱或剪力墙连接时,本工程8度设防,拉结筋沿墙通长,墙长不够时,拉结筋锚入长度按实际取。拉结筋竖向间距可取砌块规格取500通长拉结筋,拉结筋允许绑扎搭接,拉结筋保护层厚度可取20~60mm拉结筋两端另加弯钩。2、构造柱、抱框立柱、水平系梁、过梁、拉结筋的截面尺寸及配筋:(1)构造柱截面尺寸及配筋:A:构造柱截面尺寸:墙交接处或墙端部:墙厚*200mm;墙中部位置:墙厚*200mm。B:构造柱配筋:纵筋4Ø12、箍筋Ø6@100/200。构造柱纵筋应贯通或锚入主体梁板内至少500(可弯折锚固,水平段至少200)且应穿越圈梁;构造柱箍筋在楼层上下600范围内箍筋加密为@100。(2)抱框立柱截面尺寸及配筋:A:抱框立柱截面尺寸:墙厚*120mm。B:洞口宽度≥2100mm(抱框立柱通顶)或重型门时,墙厚*240配筋拉结筋2Ø6@500锚入长度700。(3)水平系梁截面尺寸及配筋详见图纸。(4)过梁截面尺寸及配筋详见图纸。(5)拉结筋配筋:本工程8度设防,拉结筋沿墙通长,墙长不够时,拉结筋锚入长度按实际取。拉结筋竖向间距可取砌块规格取500通长拉结筋,拉结筋允许绑扎搭接,拉结筋保护层厚度可取20~60mm拉结筋两端另加弯钩。3)构造柱、抱框立柱、圈梁、过梁混凝土设计强度等级均为C20。4)砌块墙体与构造柱、抱框立柱的连接处应砌成马牙槎,砌马牙槎应先退后进,以保证构造柱、抱框立柱脚为大断面。每一个马牙槎的高度不宜超过300mm,马牙槎凸槎长度不小于60mm。5)构造柱、抱框立柱、圈梁、过梁施工要点:(1)钢筋工程:钢筋采用HPB235级钢筋,钢筋绑扎前必须做除锈、调直处理。HPB235级钢筋末端应作180°弯钩。受力钢筋接长采用绑扎搭接接头,其搭接长度HPB235级钢筋为1.4×36d,同一截面钢筋接头百分率为50%,在绑扎接头区段内的箍筋间距不应大于200mm。钢筋保护层厚度一般为20mm,并不得小于15mm。钢筋保护层采用在主筋外侧卡上塑料卡保证。(2)模板工程:构造柱、抱框立柱、圈梁、过梁模板采用15mm厚双面覆膜多层板,主龙骨采用50×100mm木方,构造柱、抱
本文标题:冀东石油家园二次结构方案
链接地址:https://www.777doc.com/doc-2677765 .html