您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 能源与动力工程 > 110kV林安五林安朝线电缆修复施工方案
1110kV林安五、林安朝线电缆修复施工方案批准:安监审核:审核:编写:广西南宁国恒供电开发有限责任公司二0一四年九月2目录一、工程概况1、工程简介······················································032、工作内容、时间计划············································03二、组织措施1、施工前准备····················································042、人员组织······················································043、主要材料、主要工器具··········································04三、技术措施1、电缆井制作····················································062、电缆修复措施··················································073、电缆试验······················································07四、安全措施1、现场安全措施··················································092、安全风险辨析及控制措施········································103、其他安全措施··················································12五、环保措施1、工作前························································132、工作中························································133、工作后························································13六、应急措施·····················································13七、作业流程表八、附图九、施工人员清单3一、工程概况1.1、工程简介于2014年9月10日上午接南宁供电局通知,110kV林安五电缆线路在位于#015电缆井旁(友爱路地铁施工围挡范围内),因道路开挖施工导至运行中的电缆发生损伤的事故,我部随即安排抢修人员配合运行部门到现场进行故障勘察,经现场得知,发现110kV林安五线B相电缆和110kV林安朝线C相电缆的外护套和铝护套都已被开挖破坏,为有效防止因电缆线路故障造成的进一步扩大化电网停电事故,保障城市可靠用电,现需立即对110kV林安五线、110kV林安朝线电缆故障进行抢修。1.2、工作内容和工作时间序号工作时间工作线路工作地段工作内容12014年10月06日08:00至2014年11月07日18:001、110kV林安五线B相电缆2、110kV林安朝线C相电缆1、110kV林安五线#015电缆井至#016电缆井。1、从110kV林安五#015电缆井至自来水管转弯处进行开挖施工,检查该段电缆通道内的备用管道是否有损坏,如果发现有损坏的管道,必须重新敷设管道,再进行路面恢复;2、在电缆故障点处新建一座电缆井,提供电缆故障点的修复作业空间;(电缆井制作规格:长10米,宽2米,深1.9米)3、110kV林安五线#015电缆井已经受损,需将#015电缆井进行修复;4、待电缆井制作完成后,对110kV林安五线受损的B相电缆和110kV林安朝线受损的C相电缆进行接头安装及护套修复。5、待110kV林安五线B相电缆和110kV林安朝线C相电缆修复完成后,对这两回路电缆进行相关的电气试验。备注1、110kV林安五线电缆和110kV林安朝线电缆为共井敷设。4二、组织措施2.1、施工前准备2.1.1、工程材料、施工工器具运至现场,并整理清点;2.1.2、工作负责人组织安全员、技术员和有经验的施工人员进行现场勘察,并对施工人员进行现场交底。2.2、人员组织项目负责人:曾宪居(13557999325)工作负责人:韦保杰(15977495869)安全员:韦少飞(15977484297)技术员:陆韬(13768278544)施工员:覃乃峰、韦保杰、陈沐恩等10人。2.3、材料、工器具准备主要工器具序号名称规格单位数量备注1空压机台42铁铲83铁锹54手电筒个55气体检测仪台16数字万用表台17链条葫芦3T个48卸扣5T个69卸扣3T个1010紧线器个1011钢管根30512清洁纸包若干13绝缘带卷若干14防水带卷若干15半导电带卷若干16PVC带卷若干17铠装带卷若干2.4、对110kV林安五线电缆和110kV林安朝线电缆需要进行的试验项目及相关的设备2.4.1、110kV林安五线电缆试验项目:1)110kV电缆电缆参数、波阻抗试验;2)110kV电缆外护套遥测试验;3)110kV电缆外护套直流耐压试验;4)110kV电缆交叉互联系统检测试验;5)110kV电缆主绝缘交流耐压试验。2.4.2、110kV林安朝线电缆试验项目:1)110kV电缆电缆参数、波阻抗试验;2)110kV电缆外护套遥测试验;3)110kV电缆外护套直流耐压试验;4)110kV电缆交叉互联系统检测试验;5)110kV电缆主绝缘交流耐压试验。2.4.3、以上电缆试验所需要的相关电气设备:序号名称单位数量110000V兆欧表台12XD2905绝缘电阻测试仪台13DS-2008R输电线路直流电阻测试仪台4DS-2008异频测试仪台5回路电阻测试仪台16S1-105Z/2数字兆欧表台6三、技术措施3.1、电缆井制作(1)土方开挖→浇砼垫层C15砼→砌砖→土方回填→沟墙面抹灰→沟底水泥砂浆过面→焊接电缆支架→预制钢筋混凝土盖板。(2)砼垫层浇筑完毕及凝固后,进行电缆沟砌筑。电缆壁用M5混合砂浆砌MU10红机砖,内壁用1:2水泥砂浆抹面20厚。红砖提前一天浇水湿透,按配合比用砂浆搅拌机拌好砂浆。砌墙的方法用一顺一丁。第一排砌丁砖,最上排也砌丁砖。砌第一皮时用砂浆将底层砖调平。砖缝按10mm设置,最大不得超过12mm,最小不宜小于8mm,上下皮顺砖间竖缝错开1/2砖长,上下皮顺与丁砖间竖缝错开1/4砖长。砌砖时要仔细对照皮数杆的砖层和标高,控制好灰缝的大小,使灰缝均匀一致。挂线:砌240㎜砖墙单面挂线,砌370㎜墙必须双面挂线。挂线要求一根通长,并且拉紧,砌时每层砖穿线看平,使水平灰缝均匀一致,平直通顺。(3)砌砖:砌砖宜用一铲灰、一块砖、一挤揉的“三一”砌法,即满铺、满挤操作法,砌时砖要放平,随砌随将舌头灰刮尽。(4)水泥砂浆要随拌随用,一般应在3小时内用完(混合砂浆不超过4小时)。砌砖时要边砌边检查砌体的水平度及垂直度,随时注意纠正偏差;砌体灰缝和砂浆饱满度不得小于80%。施工过程严格按规范进行控制,按设计要求预埋焊接电缆支架的预埋件。砌体砂浆按试验单位出具的配合比严格配料,随拌随用,并留置砂浆试验试块。(5)抹灰时,待灰浆稍干及时上水泥浆面,刮光后一次性成活,24小时后开始7VF-2.ZGS-100串联谐振装置系统套18温湿度计只19试验线条若干10试验用电源车部111警戒带、警示牌若干12绝缘杆、绝缘绳条若干13安全带、绝缘垫若干7养护。(6)支架:电缆支架用50×5热镀锌扁钢焊接在一起,支架的焊接要由有电焊上岗证的人员操作。支架焊接要牢固,上下要垂直且同一标高。与地网连接的接头长度要符合有关要求,并用防锈漆涂刷防锈。(7)盖板:电缆沟的所有盖板要按照设计要求进行预制,板用混凝土的标号、钢筋及其长宽高要准确。待电气部分安装完成后,立即进行盖板的铺盖工作。盖板面上要在同一水平面上,板底部要用砂浆垫好,不得有高低不平和晃动现象。3.2、电缆修复3.2.1、施工准备(1)对故障点周围进行人工开挖施工,并在故障点处新建一座电缆井(长10米,宽2米,深1.9米),给电缆故障修复作业提供施工作业空间。(2)将故障点周围的电缆保护管拆除。(3)将故障电缆使用钢管搭架支撑起来。3.2.2、施工操作(1)电缆外护套故障点进行清洁处理,并用热风枪吹干故障点的水。(2)用玻璃片刮去故障点圆周的石墨层,其长度以故障点为中心两边至少15厘米。用绝缘带对故障点进行均匀绕包,至少绕包10层。(3)用绝缘带对故障点进行绕包,至少6层,将故障点全部覆盖绕包。(4)用防水带对故障点进行绕包,至少8层,防水带应包覆绝缘带全部覆盖。(5)用环氧树脂、玻璃纤维带对故障点进行处理,玻璃纤维带至少6层。(6)用半导电带缠绕并连通石墨层,至少绕包3层。(7)用PVC带对电缆故障点进行绕包,至少绕包2层。(8)使用铠装带对电缆故障点进行绕包覆盖,并覆盖所有PVC带的绕包层。(9)修复故障点后,再次测量故障段电缆的外护套绝缘电阻,如合格则完成工作,如仍不合格则重复步骤,继续查找下一个故障点修复,直至全部修复完毕,绝缘电阻合格为止。3.3、电缆试验(1)检查杆塔上安装的电缆头无物理连接,并将电缆引线拉开到距离其他部分足够的安全距离,如果高压引线的重量大,绝缘线的强度不够,应考虑采用绝缘物进行支撑。8如果电缆的外壳的接地线在铁塔上接地,也一并拆除。(2)将在电缆一端接地线接地,分别对电缆的主绝缘进行绝缘电阻的试验,试验电压为5kV。(3)解开电缆铠甲和外壳的接地线,使用10kV电动兆欧表对其进行耐压试验。(4)检查试验系统及电缆的接线正确无误。确认电缆铠甲和外壳为单端接地。(5)对电缆的主绝缘进行1.6U。(102kV)交流耐压实验60分钟。(6)开机。闭合空气开关或刀闸,弹起“急停”按钮,顺时针转动钥匙开关,分闸指示灯亮(绿色)。出现开机界面后,按下合闸按钮进入分压器电压等级设定界面。(7)旋转菜单导航旋钮可以使“√”形光标移动,将光标移动到与系统中分压器电压等级相应的行,按一下菜单导航旋钮,即可进入下一“试验参数设定界面”。注意:要确保选择的分压器电压等级与系统中接入的分压器额定电压等级相同,当发现选择错误时,一定要关机后重新开机正确设置。(8)在“试验参数设定”界面,通过菜单导航选钮设置试验时间为:60分00秒,设置规定的试验电压值(102kV进行耐压试验时间60分钟)。设置完后使用导航选钮“确定”,进入等待界面,等待数秒后,进入操作主界面。(9)在操作主界面上,使用导航选钮进入“参数设定”界面,选定“保护设定”菜单进入保护电压比值设定界面,设置保护电压比值(一般为1.1),确定后返回参数设定界面,“退出“后返回操作主界面。(10)在操作主界面上,选择“自动调谐”进入自动调谐界面,变频电源开始从300HZ到30HZ自动扫描,寻找系统的谐振点。(11)在找到系统谐振点后,开始手动升压。在操作主界面上,手动调节“功率调节”旋钮,加大占空比输出即可升压,减少占空比输出即可降压。(12)试验电压升高到102kV后,使用“计时开始”,时间到后系统自动降压。按钮(防止误操作),断开刀闸或空气开关。(13)在系统输出将到0后,即可按下分闸按钮,将钥匙开关转到0处,按下“急停”按钮(防止误操作),断开刀闸或空气开关。(14)电缆的主绝缘进行绝缘电阻的试验,试验电压为5kV。绝缘电阻值应与不小于试验前绝缘电阻值30%。9(15)换侧进行整体耐压试验。(16)试验完毕将电缆恢复到试验前状态,清理现场。四、安全措施工作任务:1、从110kV林安五#015电缆井至自来水管转弯处进行开挖施工,检查该段电缆通道内的备用管道是否有损坏,如果发现有损坏的管道,必须重新敷设管道,再进行路面恢复;2、在电缆故障点处新建一座电缆井,提供电缆故障点的修复作业空间;(电缆井制作规格:长10米,宽2米,深1.9米)3、110kV林安五线#015电缆井已经受损,
本文标题:110kV林安五林安朝线电缆修复施工方案
链接地址:https://www.777doc.com/doc-3095878 .html