您好,欢迎访问三七文档
1目录一、工程概况:..............................................................................................................................2二、总体施工方案..........................................................................................................................2三、主要施工方法:.......................................................................................................................33.1、土方开挖及基坑降水......................................................................................................33.2、桩基处理:......................................................................................................................33.3、模板工程..........................................................................................................................53.4、钢筋工程........................................................................................................................153.5、混凝土工程....................................................................................................................223.6、导流墙砌筑....................................................................................................................253.7、水池试水........................................................................................................................27四、质量保证措施........................................................................................................................314.1质量目标...........................................................................................................................31项目部质量保证体系图.................................................................................................................32项目技术质量管理流程图.........................................................................................334.2质量保证体系...................................................................................................................354.3组织保证措施...................................................................................................................354.4质量管理制度................................................................................................................354.5技术保证措施...................................................................................................................37五、安全技术措施和保证制度.....................................................................................................385.1安全生产目标................................................................................................................395.2安全生产保证体系........................................................................................................395.3安全生产教育...................................................................................................................405.4安全技术措施和保证制度...............................................................................................405.5工程安全措施...................................................................................................................412辽通化工大伙房水源工程清水池施工方案一、工程概况:本工程系辽通化工大伙房水源工程项目之一,包括43.2×54.6m清水池两座,两池水平距离900mm。水池设计埋深5m,底板下为预应力管桩基础,池内净高5m,底板设计上标高-0.3m,底板厚500mm,池壁厚350mm,顶板厚250mm,现浇钢筋混凝土结构,池内支撑顶板的现浇柱柱距为3800×3800mm,每座水池中间在长度方向设一道1m宽的后浇带,宽度方向设一道30mm的伸缩缝,缝缝内设橡胶止水带。池内导流墙采用Mu10烧结实心砖M10水泥砂浆砌筑,1:2水泥砂浆抹面,顶板上部覆土厚度1000mm。在池顶板上面设有三元乙丙卷材防水层,防水层上面及1.2m高外侧墙面铺设挤塑型聚苯乙烯保温板,顶板保温板厚50mm,侧墙保温板厚60mm,顶板保温板上面保护层做法为50mm厚细石混凝土内配ф6钢筋网@200,侧面保温板保护层做法为40mm厚1:2.5水泥砂浆内配ф4钢筋网@100。混凝土强度等级:垫层C15,水池结构C30S8防水混凝土。钢筋采用:HPB300,HRB335。本工程设计标高采用绝对高程。二、总体施工方案由于每座清水池分别由后浇带和伸缩缝分成四块,因此每个水池3考虑按自然块分次施工,每块分两次施工,4个自然块之间组织流水作业,第一次施工底板及500mm高池壁,在▽0.200m标高处的墙体上设一道水平施工缝,为尽可能减少施工缝的数量,提高混凝土的防水效果,▽0.200m以上墙体及顶板和池内现浇柱组织一次施工,不再设施工缝。三、主要施工方法:3.1、土方开挖及基坑降水详见相应专项施工方案,采用机械挖土施工作业过程中,需注意各部位挖土标高变化,并作好预制桩的成品保护工作,如因不慎造成断桩,应与设计及监理有关人员协商确定处理措施,并确定的处理方法进行接桩。3.2、桩基处理:本工程水池底板下桩基础均为抗拨桩,施工前应按设计有关要求对桩项进行直芯处理,埋芯高度为3m,填芯处理方法如下图所示:4桩基与水池底板的连接按标准图集(10G409)第41、42页节点进行施工,桩头伸入底板50mm,截桩桩顶与底板连接时,桩身全部纵向钢筋全部锚入底板,钢筋锚入长度不小于50d,且不小于500mm。桩顶与底板的连接如下图所示:5预应力管桩桩头需做防水处理,其做法按设计要求如下图所示:3.3、模板工程3.3.1、本工程水池池壁、顶板、现浇柱均采用16mm厚清水木模板支6设,采用钢管及50*80木方做横立椤,采用M10对拉螺栓固定,为保证墙体上水平施工缝的防水质量,池壁水平施工缝设置300mm宽钢板止水带,止水带需做成企口形式,如下图所示,设在墙体中间部位,埋入上、下墙体各150mm,当止水带与预埋套管相遇时,将止水带与套管止水环进行焊接,钢板止水带接头搭接长度应大于100mm,并延止水带宽度方向进行满焊。钢板止水带安装如下图所示:用于加固墙体模板的对拉螺栓中间均设100×100×3的止水钢7板,对拉螺栓的规格为M10,对拉螺栓参照上图间距改为450×450mm,在支设施工缝上部墙体模板时,上层墙体模板的底部要固定在施工缝下部墙体第一排对拉螺栓上,以保证上、下节墙体连接顺畅,为防止混凝土浇筑时模板底部漏浆,在施工缝下部墙体两侧贴一条泡沫密封条。水池顶板采用ф48*3.5钢管满堂支架做支撑系统,钢管布置间距按800mm考虑。纵横水平拉结杆间距按1500mm设置,剪刀撑按四排6步纵横设置。支撑系统如下图所示:893.3.2、后浇带施工:在清水池中间部位沿长度方向设计有一条宽1000mm贯穿底板、墙壁及顶板的后浇带,原设计后浇带结构形式如下图所示:原设计后浇带内止水措施是采用橡胶止水带,而在拆除止水带下面的模板时,极易造成橡胶止水带的破坏,给后浇带处带来漏水隐患,因此本方案要求将原设计的橡胶止水带和BW遇水膨胀止水条取消,采用300×3的钢板止水带。如下图所示:103.3.3、伸缩缝施工伸缩缝要严格按图纸所示的位置设置,底板下的外贴止水带采取先置法预铺在伸缩缝处,在伸缩缝一侧的混凝土浇筑完毕后24小时内应将封头模板及时拆除,拆模时要对缝内的橡胶止水带加以保护,缝内的聚氯乙烯闭孔泡沫止水板采取先置法,用建筑胶粘贴在已浇筑混凝土的侧面上,双组分聚硫密封膏采取后置法,先用30mm厚的挤塑板贴在密封膏处,待另一侧混凝土浇筑完毕拆模后,将挤塑板扣出,清除缝内杂物,并用压缩空气吹扫干净后注入密封膏。底板、墙壁、顶板处伸缩缝做法如下图所示:11123.3.4、防水套管制作与安装本工程中穿混凝土墙、板的预留孔洞均设刚性防水套管,安装前必须仔细进行核对,套管的规格必须按图纸要求所示采用,采用钢管加工时,应采用机械切割器切割,以保证套管的长度正确,两端整齐,中间止水环的厚度、宽度必须符合标准图集要求,止水环与套管间必须双面满焊,分件制作
本文标题:清水池施工方案
链接地址:https://www.777doc.com/doc-3126709 .html