1砌块墙体施工与验收规程2007年8月14日2目录前言·······················································································3砌块墙体施工与验收规程···························································41总则····················································································42加气混凝土砌块材料选择························································53加气砼砌块的使用范围···························································64加气砼砌块砌筑及抹灰砂浆要求···············································65对加气砼砌块生产厂家的要求··················································76加气砼砌块龄期及现场堆放要求···············································77砌筑工程·············································································78抹灰工程············································································169质量监控············································································1810墙面设置控制缝的施工工艺流程与操作要点·····························1911工程质量验收······································································203前言砌体工程是房屋建筑一重要组成部份,其施工质量关乎墙体与饰面层的整体性、稳定性和耐久性。为确保墙体工程的质量,我们针对新型砌块墙材的物理特性与目前砌体工程所存在的质量问题,参照广东省建筑施工工法(粤建协[2006]39号)与同行中同等经验与做法,在国家、行业与地方现行的法律、法规与标准规范、规程的基础上,对砌体与抹灰工程的选材、节点的构造、施工、质量控制与验收等方面作出了明细的规定,以确保工程的质量,特制定本规程。本规程的黑体字部份条文为国家强制条文,或万科深圳区域强制性条文,必须严格执行。本规程具体解释由万科深圳区域工程技术与监控部负责。在规程执行过程中,请各单位结合工程实践,认真总结经验,如发现需要修改和补充之处,请将意见和建议函告万科深圳区域工程技术与品控部(地址:;邮政编号:;电邮地址:),以供今后修订时参考。本规程在编制过程中得到东莞市彩丽建筑维护技术有限公司的大力支持,在此特别鸣谢。4砌块墙体施工与验收规程1总则1.1为规范万科深圳区域所有在建项目的砌体工程的设计、施工和质量监控与验收,合理地利用砌筑材料,做到技术先进、经济合理、节约能源及确保工程质量,特制订本规程。1.2适用范围:本规程适用于万科深圳区域所有在建项目招投标及砌体与抹灰工程的施工与验收。1.3本规程黑体部分须严格执行1.4除另有注明外,本规程须符合设计、图纸和相关国家、地方及行业标准,主要包括但不限于:1.4.1《工程建设标准强制性条文》2007年版1.4.2《砌体结构设计规程》(GB50003-2001)1.4.3《非承重蒸压灰砂砖墙体工程技术规程》(DBJ/T15-32-2003)1.4.4《蒸压加气混凝土用砌筑砂浆与抹面砂浆》(JC890-2001)1.4.5《蒸压加气混凝土砌块》(GB/T11968-1997)GB/T119681.4.6《建筑工程施工质量验收统一标准》(GB50300-2001)1.4.7《建筑装饰装修工程施工及验收规范》(GB50210-2001)1.4.8《住宅装饰装修工程施工规范》(GB50327-2001)1.4.9《砌体工程施工质量验收规范》(GB/T50203-2002)1.4.10《放射性标准》(GB6566-2001)1.4.11《民用建筑工程室内环境污染控制规范》(GB50325一2001)1.4.12《加气混凝土性能试验方法》(GB/T11969~11975-1997)1.4.13结构要求及装饰要求详附件图纸1.4.14深圳市标准《非承重砌体与饰面工程施工及验收规范》(SJG13—2004)1.4.15深圳市标准《非承重砌块墙体设计规范》(SJG13—2004)1.4.16万科(深圳区域)工程技术统一标准《楼宇(建筑部分)实体无损检测验收规程》。1.4.17彩丽建筑维护技术有限公司企标(Q/CL1-2006)《新型砌块墙体干法施工用CL专用砂浆》。51.4.18广东省建筑施工工法(粤建协[2006]39号)。1.4.19若承包商对以下要求有任何疑义,应立即向万科地产提出,由万科地产做最终决定,否则视为接受。2、加气混凝土砌块材料选择2.1采用混合型加气砼砌块及灰砂加气砼砌块,慎用粉煤灰加气砼砌块。2.2材料规格及技术指标要求:加气混凝土砌块应符合以下规定:(1)加气混凝土砌块的常用规格尺寸(mm)长度L宽度B高度H600100150200250200250300120180240注:表内未列的规格尺寸可由用户与制造厂家商定。(2)加气混凝土砌块的抗压强度(MPa)强度等级立方体抗压强度平均值不小于单块最小值不小于A3.53.52.8A5.05.04.0A7.57.56.0(3)加气混凝土砌块的强度等级体积密度等级B05B06B07强度等级优等品(A)A3.5A5.0A7.5一等品(B)A3.5A5.0A7.5合格品(C)——A3.5A5.0(4)加气混凝土砌块的体积密度(kg/m3)体积密度等级B05B06B07体积密度优等品(A)≤500≤600≤700一等品(B)≤530≤630≤730合格品(C)≤550≤650≤7506(5)加气混凝土砌块的干燥收缩值和导热系数干体积密度等级B05B06B07干燥收缩值标准法mm/m≤0.50快速法≤0.80导热系数(干态),W/(m·K)≤0.14≤0.16——注:1.规定采用标准法、快速法测定砌块干燥收缩值,若测定结果发生矛盾不能判定时,则以标准法测定的结果为准。2.用于墙体的砌块,允许不测导热系数。2.2.1外墙及分户墙:主要规格600×200×200/600×240×200(长×宽×高),立方体抗压强度≥5.0MPa,内墙用≥5.0MPa,干体积密度为7kg/m3。2.2.2其余内隔墙:主要尺寸为600×100×200,立方体抗压强度≥5.0MPa,干体积密度为7kg/m3。2.2.3干燥收缩值:≤0.50mm/m。2.2.4材料等级:优等品。3加气砼砌块的使用范围加气混凝土砌块适用于各类建筑地面(±0.00)以上的内外墙和地面以下的内隔墙(有特殊要求的墙体除外),但如不采取有效的防护措施,不得在以下部位使用:3.1建筑物±0.00以下(地下室的非承重内隔墙除外)部位。3.2长期浸水或经常干湿交替的部位。3.3受化学浸蚀的环境,如强酸、强碱或高浓度二氧化碳等的环境。3.4砌块表面经常处于80℃以上的高温环境。3.5屋面女儿墙。4加气砼砌块砌筑及抹灰砂浆要求4.1砌筑砂浆:必须采用与墙体材料相适应、粘结强度大于0.2MPa的CL专用砂浆,原则上每立方米砂浆的水泥用量应大于或等于270kg,其粘结的破坏形式应为砌块内聚破坏,不允许存在粘结面破坏。4.2抹灰砂浆:必须采用与墙体材料相适应的专用砂浆(如CL专用砂浆)。用于室内的抹灰砂浆,其粘结强度应大于0.3MPa;用于户外的抹灰砂浆,其粘结强度应大于0.4MPa,且抗渗值小于0.3ml/min。75对加气砼砌块生产厂家的要求5.1年生产能力大于20万立方米,堆场堆放能力1万立方米以上,公司必须有严格的质量管理体系及质量保证体系。5.2生产工艺和设备必须比较先进和现代化:原材料质量可靠、配料必须有电脑严格控制,有三面切割的自动化切割设备,蒸压养护设备有可靠的压力和温度供给和控制。6加气砼砌块龄期及现场堆放要求6.1加气砼砌块的出厂龄期不得少于28天。加气砼砌块进入现场堆放时间必须不少于15天;墙体砌筑完毕,间隔15天进行顶砖施工;顶砖施工完毕,间隔7天进行墙面抹灰。6.2加气砼砌块堆放场地必须采用100×50木方立放,上部设置18厚模板并与木方钉牢,堆场周边应有良好的排水措施,以免雨天因排水不畅导致加气砼砌块浸泡。雨天应采用雨布进行遮盖。堆场应具备下垫上盖足够的防雨防潮措施。6.3现场堆放的加气砼砌块应做标识牌,注明进场日期以及检验情况。7砌筑工程7.1砌筑墙体前的准备工作7.1.1在砌筑墙体施工前必须将图纸与施工现场反复核对、效正,并进行标注;(特别是门、窗洞口的大小尺寸等)7.1.2在砌筑墙体施工前按设计图纸进行放线;7.1.3设置导墙的要求:加气混凝土砌块墙体,其墙体的底部应现浇与砌体同厚度C20素混凝土的导墙。,其设置高度应为(填充墙的总高度㎜-斜项砖的高度180/200mm)÷(砌块的高度200/250㎜+灰缝12mm)(注:整除后的余数,即为导墙的设置高度,如余数不足100mm,则另加一皮砌块的高度。)(如图1所示)8图1导墙设置方法7.1.4墙体拉结钢筋设置要求:砌块墙与承重墙或柱交接处,应在承重墙或柱的水平灰缝内预埋拉结钢筋,拉结钢筋沿墙或柱高每600mm左右(与砌块模数相同)设一道,每道为2根直径6mm的钢筋(带弯钩),拉结钢筋通长设置,在砌筑砌块时,将此拉结钢筋伸出部分埋置于砌块墙的水平灰缝中。拉结筋采取预埋方式设置,砌筑前需检查拉结钢筋数量及位置,对于不准确或缺漏的拉结钢筋,建议按照实际排砖位置钻孔(深度100mm以上),孔洞应采用专用的钢丝刷,配合压缩空气清理干净,再采用植筋胶进行植筋,后植的拉结钢筋其抗拉强度应≥2.0KN;如承建商采用其它方式进行后设拉结钢筋的方式,需向我司项目经理部申报,经我司项目经理部批准后方能实施。7.1.5砌筑施工械具配备要求a)灰刀b)锤c)吊线d)卷尺e)手锯f)勾缝器g)灰槽图1:导墙的设置的方法97.2砌筑墙体的基本要求a、应采用具有高粘结力,并适用干法施工的CL专用砂浆砌筑墙体。砌筑墙体的CL专用砂浆的性能应在施工过程中,按本规程“第9条质量监控”的要求进行监控。b、砌筑砂浆应放入灰槽内,禁止直接堆在地坪。c、应严格按照施工用量的要求合理调配砂浆,存放在砌筑墙体现场的砂浆应在2小时内用完。新拌的砂浆其搁置时间超过4小时后,严禁再使用。d、砌筑墙体时,施工应在砌块的挡头部位敷抹专用砂浆,以挤浆方法砌筑上墙。施工将砌块放置上墙后,应以锤击方式挤浆,将砌块一次性校平摆正。e、砌筑填充墙的收口应设置在中间部位,收口部位的竖向灰缝以插浆法施工,宜用内外临时夹板夹住后灌缝,其宽度不得大于20mm;f、施工应遵循合理组砌的原则砌筑墙体,其具体的要求如下:1)砌体的砌块应错缝咬合,其上下皮砌块的竖向缝灰相互差开的间距应大于或等于砌块长度1/3,如未达到这一要求,应在其之间的水平灰缝部位设置钢筋,以提高其剪应力。2)门梁、窗梁所承压的砌块原则上为整砖(如图二所示)。g、砌体的灰缝应控制在12~15mm范围内,其水平灰缝的饱浆率应≥90%,竖向灰缝的饱浆率应≥80%,并应达到横平垂直,大小均一的要求。h、砌筑墙体时,其每天砌筑墙体的施工高度应控制在1.5米范围内;当砌筑至梁、板底180/200mm时,应间隔7天再砌
本文标题:加气砼砌块砌筑技术规程
链接地址:https://www.777doc.com/doc-3150203 .html