您好,欢迎访问三七文档
当前位置:首页 > 医学/心理学 > 药学 > 丹佛斯FC300系列变频器参数讲解
VLT®AutomationDrive1DanfossDrivesA/S2参数表•安装•编程•参数–0-**操作和显示–1-**负载和电机–2-**制动–3-**参考值/加减速–4-**限制/警告–5-**数字输入/输出–6-**模拟输入/输出–7-**PID控制器–13-**智能逻辑控制器–14-**特殊功能–15-**变频器信息–16-**数据读出–17-**编码器•警告(WARNING)和报警(ALARM)•选件和附件DanfossDrivesA/S3InstallationMechanicalInstallationDanfossDrivesA/S4InstallationMechanicalInstallationDanfossDrivesA/S5外壳类型MechanicalInstallationDanfossDrivesA/S6InstallationElectricalInstallation强电端子•电机端子•电源端子•制动及负载共享•继电器•LC滤波器•外部24V供电DanfossDrivesA/S7InstallationElectricalInstallationControlteminalsDanfossDrivesA/S8InstallationElectricalInstallationTensionspringtechnology•接线•拆线•连接DanfossDrivesA/S9InstallationElectricalInstallationControlTerminalDiagramDanfossDrivesA/S10InstallationElectricalInstallationDanfossDrivesA/S11InstallationElectricalInstallation•开关S201,S202,andS801开关S201(A53)、S202(A54)用来选择53/54端子的电流(0-20mA)或电压输入(-10to10V)开关S801(BUSTER.)是RS-485口的终端电阻开关(terminals68and69).默认值:S201(A53)=OFF(电压input)S202(A54)=OFF(电压input)S801(终端电阻)=OFF断电状态下拨动开关,拨动时最好摘下面板的底托,小心用力!DanfossDrivesA/S12亮Status暗Status显示亮度ProgrammingOperatingInstruction14-22工作模式14-50射频干扰滤波器15-43软件版本恢复出厂值按住同时上电,保持5秒(orP.14-22)OkMainMenuStatusOrpressfor3sMainMenuQuickMenu快捷(directaccess)MainMenuMainMenu-Key1xpushing-lastchangedParameter2xpushing-MainmenuImportantsettings:DanfossDrivesA/S130-01Language[1]EnglishUser-Menu0-01Language[1]EnglishCommissioning-MQ4Last10Q5AllChangesListofchangesSpeed[RPM]Current[A]Output[kW]Frequency[Hz]ProtokolleProtocolsOkBackProgrammingQuickMenuQ1User-MenuQ2Commissioning-MenuQ3ListofchangedparameterQ4Last10changesQ5AllchangesQ6Protocols0-01Language[1]EnglishLast10Changes0-01Language[1]EnglishAllChangesOkBackQ1User-MenuQ2CommissioningQ3ListofchangesQ6ProtocolsQuickmenuDanfossDrivesA/S14ProgrammingMenuStructureMainMenuMaingroup-choiseGroup2-**Group16-**Group1-**Group0-**0-**Operation/Display1-**Motor/Load2-**Brakefunction3-**Reference/Ramps4-**Limits/Warnings5-**DigitaleIn-/Outputs6-**AnalogeIn-/Outputs7-**ClosedLoop8-**Options/Interfaces13-**SmartLogic14-**SpecialFunctions15-**Triplog/Maintenance16-**DatareadoutsUndergroup-choise2-0*2-2*16-0*16-8*1-0*1-8*0-0*0-6*OkBack0-040-010-660-601-011-001-811-802-032-002-232-2016-0616-0016-8616-80Parameter-choiseOkBackDanfossDrivesA/S150-**Operation/Disp1-**Motor/Load2-**Brakefunctio3-**Ref./RampsMaimenuMainMenuProgrammingExample1-00Configura[0]OpenLoopDefaultsettings1-20Motordata4kwMotordataOkBack1-0*Defaultset1-2*Motordata1-3*Motordata(1-4*TemperaturLoad/Motor2-0*DC-Hold/DC.2-1*Overvoltage2-2*Mech.BrakeBrakefunctionen16-0*Readout-All16-1*Readout-M16-3*ReadoutF16-5*Readout-SDatereadouts0-o*Defaultsett0-1*Parameterset0-2*LCP-Display0-3*LCPKeysDisplay/OperationOkBackMainMenuDanfossDrivesA/S16ProgrammingArrayParameterParameterArrayNumberFunction3-100PresetRef.11PresetRef.22PresetRef.33PresetRef.44PresetRef.55PresetRef.66PresetRef.77PresetRef.8ArrayNumberArrayValue0RPM0.00A1(1)References3-10PresetRef.[0]0,00%References3-1*OkOk0RPM0.00A1(1)References3-10PresetRef.[0]0,00%References3-1*BackBackCancelorOkor0RPM0.00A1(1)References3-10PresetRef.[0]0,00%References3-1*ArrayInputDanfossDrivesA/S17ParametersOperationandDisplayGroup0OperationandDisplay0-01LanguageValue:*English(ENGLISH)[0]German(DEUTSCH)[1]French(FRANCAIS)[2]Danish(DANSK)[3]Spanish(ESPANOL)[4]Italian(ITALIANO)[5]Swedish(SWEDISH)[6]Dutch(DUTCH)[7]Chinese(CHINESE)[10]Finnish(FINNISH)[20]EnglishUS(ENGLISHUS)[22]Greek(GREEK)[27]Portuguese(PORTUGUESE)[28]Slovenian(SLOVENIAN)[36]Korean(KOREAN)[39]Japanese(JAPANESE)[40]Turkish(TURKISH)[41]TraditionalChinese[42]Bulgarian[43]Serbian[44]Romanian(ROMANIAN)[45]Hungarian(HUNGARIAN)[46]Czech[47]Polish(POLISH)[48]Russian[49]Thai[50]BahasaIndonesian(BAHASAINDONESIAN)[51]0-0*Operation/DisplayParametersrelatedtothefundamentalfunctionsofthefrequencyconverter,functionoftheLCPbuttonsandconfigurationoftheLCPdisplay.0-0*BasicSettingsParametergroupforbasicfrequencyconvertersettings.DanfossDrivesA/S18ParametersOperationandDisplayGroup0OperationandDisplay0-02MotorSpeedUnitValue:*RPM[0]Hz[1]Selectdisplayofmotorspeedparameters(i.e.references,feedbacksandlimits)intermsofshaftspeed(RPM)oroutputfrequencytothemotor(Hz).0-03RegionalSettingsValue:*International[0]US[1]SelectInternational[0]tosetpar.1-20MotorPowerunitstokWandthedefaultvalueofpar.1-23MotorFrequencyto50Hz.SelectUS[1]tosetpar.1-21MotorPowerunitstoHPandthedefaultvalueofpar.1-23MotorFrequencyto60Hz.DanfossDrivesA/S19ParametersOperationandDisplayGroup0OperationandDisplay0-10ActiveSet-upValue:0-1*Set-upOperationsDefineandcontroltheindividualparametersetups.Factorysetup[0]*Set-up1[1]Set-up2[2]Set-up3[3]Set-up4[4]Multiset-up[9]Selecttheset-uptocontrolthefrequencyconverterfunctions.FactorySet-up[0]cannotbechanged.ItcontainstheDanfossdataset,andcanbeusedasadatasourcewhenreturningtheotherset-upstoaknownstate.Set-up1[1]toSet-up4[4]arethefourseparateparameterset-upswithinwhichallparameterscanbeprogrammed.SelectActiveSet-up[9]forremoteselectionofset-upsusingdigitalinputsandtheserialcommunicationport.Thisse
本文标题:丹佛斯FC300系列变频器参数讲解
链接地址:https://www.777doc.com/doc-3518331 .html