您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 经营企划 > Uniflair精密空调技术参数手册
优力恒温恒湿精密空调技术参数第一页:S风冷第二页:T风冷第三页:T风冷1第四页:T-MAX第五页:S冷冻水第六页:T冷冻水第七页:T节能第八页:T节能1第九页:T-MAX节能第十页:T双冷源*S代表Amico系列,T代表Leonarno系列SDA/SUA风冷机组SDW/SUW水冷机组0151025103310351SUA0501SUW0501SDA0501SDW0501SUA0601SUW0601SDA0601SDW0601额定制冷容量(房间条件:24℃-50%Rh)S*A风冷机组总冷量kw冷凝温度48℃显冷量kw6.15.88.68.310.510.013.613.017.616.917.617.620.619.420.719.8S*W水冷机组总冷量kw冷凝温度55℃显冷量kw水流量l/s6.65.90.349.28.50.4811.110.30.5714.513.40.7418.817.60.9419.018.00.9422.020.21.1022.120.71.10输入电源V/ph/HZ230/1/50或400/3+N/50400/3+N/50前曲叶片式离心风机驱动风机数量额定风量m3/h额定静压Pa额定功率(每个)kw高静压机型风机数量额定静压Pa额定功率(每个)kw直接11580800.2511200.57直接12580800.38511200.57直接13040800.4311200.57直接23040800.2521200.57直接35740800.3531200.57直接25940800.5731200.57直接35740800.3531200.57直接25960800.5731200.57压缩机形式数量额定功率kw涡旋式11.45涡旋式12.0涡旋式12.3涡旋式12.9涡旋式13.5涡旋式13.5涡旋式14.3涡旋式14.3蒸发盘管表面积m20.220.220.3030.3850.5780.5780.5780.578空气过滤器正面尺寸mm厚度mm410X57550410X57550560X57550710X575501060X575501060X575501060X575501060X57550电加热器标准容量元件数量总功率kw高容量元件数量总功率kw12241224123613262639263926392639电极式加湿器额定蒸汽产生量kg/h额定功率kw21.521.521.521.532.232.232.232.2新风过滤器连接直径mm额定风量m3/h80908090809080908090809080908090噪音上送风min.dB(A)41.141.144.949.948.948.9Max.dB(A)47.947.948.951.652.352.3下送风min.dB(A)40.840.844.448.147.947.9MaxdB(A)46.546.547.749.851.151.1尺寸和重量宽度mm厚度mm高度mm净重kg550450174013055045017401307004501740150850450174018512004501740260120045017402601200450174026012004501740260接管冷媒管路:排气管/液管mm水冷冷凝器(S*W)冷凝水排水加湿器进水/排水mm热水盘管16/121/2”3/8”FNPT6/211/2”GASM16/121/2”3/8”FNPT6/211/2”GASM16/121”3/8”FNPT6/211/2”GASM16/161”3/8”FNPT6/211/2”GASM16/161”3/8”FNPT6/213/4”GASM16/161”3/8”FNPT6/213/4”GASM16/161”3/8”FNPT6/213/4”GASM16/161”3/8”FNPT6/213/4”GASMS*A机组:建议冷凝器数量11111111标准配置CAL0251CAL0251CAL0331CAL0361CAL0511CAL0511CAL0661CAL0661数量11111111低噪音配置CAL0251CAL0331CAL0361CAL0511CAL0661CAL0661CAL0801CAL0801S*W机组:建议干冷器数量11111111型号RAL360RAL360RAL0510RAL0700RAL1000RAL1000RAN1000RAN1000*制冷剂R22T*AR/T*AV风冷机组T*WR/T*WV水冷机组05110611072107220921092210211022额定制冷容量(房间条件:24℃-50%Rh)T*AR风冷机组总冷量kw冷凝温度48℃显冷量kw20.320.323.722.427.127.127.127.133.031.433.031.436.733.336.733.3T*WR水冷机组总冷量kw冷凝温度55℃显冷量kw23.822.531.530.8输入电源V/ph/HZ400/3+N/50后曲叶片式离心风机(型号为T*AR&T*WR)驱动风机数量马达数量额定风量m3/h额定静压Pa额定功率(每个)kw直接1157401900.83直接1181801900.83直接1181803832.0直接1181803832.0直接1192003832.1直接1192003832.1直接1197403832.2直接1197403832.2EC风机(选件)(型号为T*AV&T*WV)驱动风机数量马达数量额定风量m3/h额定静压Pa额定功率(每个)kw直接1182205820.98直接1182205820.98直接1194005821.05直接1194005821.05直接1198505821.1直接1198505821.1压缩机形式数量制冷回路额定功率kw涡旋式115.0涡旋式115.3涡旋式213.0涡旋式223.0涡旋式213.8涡旋式223.8涡旋式214.4涡旋式224.4EU4-5空气过滤器数量正面尺寸-厚度(每个)mm总面积m22445X830X752.152445X830X752.153397X845X1003.763397X845X1003.763397X845X1003.763397X845X1003.763397X845X1003.763397X845X1003.76电加热器级数标准容量元件数量总功率kw额定运行电流A高容量元件数量总功率kw额定运行电流A1268.739131268.739133391351521.73391351521.73391351521.73391351521.73391351521.73391351521.7电极式加湿器额定蒸汽产生量kg/h额定功率kw高容量额定蒸汽产生量kg/h额定功率kw53.9386.2953.9386.2986.291511.886.291511.886.291511.886.291511.886.291511.886.291511.8热水加热盘管(选件)表面积m2阀尺寸加热量kw水流量(45/40℃℃)1/h盘管压降(包括阀门)kpa0.643/4”122020400.643/4”122020400.841”15.62760410.841”15.62760410.841”15.62760410.841”15.62760410.841”15.62760410.841”15.6276041新风过滤器(选件)连接直径mm额定风量m3/h100130100130100130100130100130100130100130100130尺寸和重量宽度mm厚度mm高度mm净重kg1010750196028010107501960280131086519604301310865196043013108651960430131086519604301310865196043013108651960430接管冷媒管路:排气管/液管mm水冷冷凝器(T*WR)冷凝水排水加湿器进水/排水mm热水盘管19/163/8”FNPT6/253/4”GAS19/163/8”FNPT6/253/4”GAS22/163/8”FNPT6/253/4”GAS2X19/2X163/8”FNPT6/253/4”GAS22/1611/4”3/8”FNPT6/253/4”GAS2X19/2X163/8”FNPT6/253/4”GAS25/193/8”FNPT6/253/4”GAS2X19/2X163/8”FNPT6/253/4”GAST*AR机组:建议冷凝器数量11121212型号40℃CAL0661CAL0661CAL0801CAL0331CAL1011CAL0361CAL1301CAL0511数量11121212型号45℃CAL0661CAL0801CAL0801CAL0361CAL1011CAL0511CAL1301CAL0511T*WR机组:建议干冷器数量11型号RAL1500RAL1500*制冷剂R22T*AR/T*AV风冷机组T*WR/T*WV水冷机组11211122132113221422162218222202额定制冷容量(房间条件:24℃-50%Rh)T*AR风冷机组总冷量kw冷凝温度48℃显冷量kw40.340.340.340.344.144.144.144.153.753.761.259.968.863.581.578.6T*WR水冷机组总冷量kw冷凝温度55℃显冷量kw43.443.461.259.567.862.781.878.7输入电源V/ph/HZ400/3+N/50后曲叶片式离心风机(型号为T*AR&T*WR)驱动风机数量马达数量额定风量m3/h额定静压Pa额定功率(每个)kw直接22125704551.6直接22125704551.6直接22125704551.6直接22125704551.6直接22167304232.06直接22167304232.06直接22179204232.1直接22226443862.8EC风机(选件)(型号为T*AV&T*WV)驱动风机数量马达数量额定风量m3/h额定静压Pa额定功率(每个)kw直接22129706200.84直接22129706200.84直接22129706200.84直接22129706200.84直接22172305351.1直接22172305351.1直接22185205331.1直接22232005361.15压缩机形式数量制冷回路额定功率kw涡旋式214.4涡旋式224.4涡旋式215.0涡旋式225.0涡旋式225.6涡旋式226.7涡旋式227.7涡旋式229.2EU4-5空气过滤器数量正面尺寸-厚度(每个)mm总面积m24397X845X1005.014397X845X1005.014397X845X1005.014397X845X1005.015410X845X1006.475410X845X1006.475410X845X1006.475410X845X1006.47电加热器级数标准容量元件数量总功率kw额定运行电流A高容量元件数量总功率kw额定运行电流A351521.761826.0351521.761826.0351521.761826.0351521.761826.0351521.761826.0351521.761826.0351521.761826.0361826.082434.8电极式加湿器额定蒸汽产生量kg/h额定功率kw高容量额定蒸汽产生量kg/h额定功率kw86.291511.886.291511.886.291511.886.291511.886.291511.886.291511.886.291511.886.291511.8热水加热盘管(选件)表面积m2阀尺寸加热量kw水流量(45℃/40℃)1/h盘管压降(包括阀门)kpa1.151”22.53920661.151”22.53920661.151”22.53920661.151”22.53920661.492”
本文标题:Uniflair精密空调技术参数手册
链接地址:https://www.777doc.com/doc-3714019 .html