您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 质量控制/管理 > 现浇轻质泡沫混凝土应用技术规程
1江苏省工程建设标准DGJJXXXXX-2010DGJXX/XXXX-2010现浇轻质泡沫混凝土应用技术规程2010-XX-XX发布2010-XX-XX实施江苏省建设厅审定发布2目次1总则······································································12术语、符号···································································22.1术语·································································22.2主要符号······························································33材料·········································································43.1原材料·································································43.2配合比·································································43.3试验方法······························································64设计·········································································74.1一般规定······························································74.2现浇轻质泡沫混凝土屋面保温层设计··························74.3现浇轻质泡沫混凝土地暖保温层设计··························85施工·······································································105.1一般规定·······························································105.2现浇轻质泡沫混凝土屋面保温层施工·························115.3现浇轻质泡沫混凝土地暖保温层施工························125.4养护··································································125.5季节性施工·························································136验收·······································································146.1一般规定·······························································146.2主控项目····························································146.3一般项目····························································15附录A发泡剂性能检验方法·············································17本标准用词说明·······························································19条文说明····································································2011总则1.0.1为规范现浇轻质泡沫混凝土在保温、隔热方面的应用,正确、合理地选择相应的配合比与施工工艺,保证施工质量,特编制本技术规程。1.0.2本规程适用于新建、改建的工业建筑、民用建筑保温、隔热工程的设计、施工及质量验收。1.0.3设计人员应根据国家节能设计标准及有关规定和要求,经热工计算,确保保温材料的厚度及特定构造、做法,以保证不同建筑节能保温隔热要求。1.0.4现浇轻质泡沫混凝土保温层的设计、施工及质量验收,除应遵守本规程的规定外,尚应符合国家现行有关标准、规范的规定。22术语、符号2.1术语2.0.1现浇轻质泡沫混凝土lightweightfoamconcrete现浇轻质泡沫混凝土是以水泥为主要胶凝材料,添加一定量的水、外加剂拌和成浆体,再与发泡剂、水、气混合发泡而成的泡沫进行机械混合后,现场浇筑或入模凝固形成具有良好保温隔热等特性的混凝土制品。2.0.2发泡倍数foammultiple泡沫体积大于发泡剂水溶液体积的倍数。2.0.3沉降距sedimentationdistance泡沫柱在单位时间内沉陷的距离。2.0.4泌水量secretionofwater单位体积的泡沫完全消失后所分泌出的水量。2.0.5保温层insulatinglayer用以阻挡热量传递,减少无效热耗的构造层,又称隔热层、绝热层,本规程中通称保温层。2.0.6填充层packedlayer在保温层上设置保护加热管并使地面温度均匀的构造层。2.0.7干体积密度desiccatedbulkdensity泡沫混凝土保温层养护28天后,测定的每立方米泡沫混凝土的绝干质量。32.2主要符号m——拟配制泡沫混凝土单位体积的质量;cm——拟配制泡沫混凝土单位体积的水泥用量;wm——拟配制泡沫混凝土单位体积的用水量;PV——拟配制泡沫混凝土泡沫体积;C——水泥的表观密度;w——水的密度。43材料3.1原材料3.1.1现浇轻质泡沫混凝土应采用32.5级及以上强度等级的水泥,应符合《通用硅酸盐水泥》GB175标准的要求。不同等级、厂家、品种、出厂日期的水泥不得混存、混用。3.1.2现浇轻质泡沫混凝土采用的发泡剂应质量可靠、性能良好,严禁使用过期、变质的发泡剂,液体发泡剂目测应均匀无明显沉淀物。3.1.3发泡剂物理性能指标应符合表3.1.3的规定。3.1.3现浇轻质泡沫混凝土发泡剂的性能指标项目计量单位指标发泡倍数倍≥20泡沫的沉降距(1h)mm≤10泡沫的泌水量(lh)mL≤203.1.4现浇轻质泡沫混凝土中掺入早强剂、防冻剂、憎水剂等外加剂时,外加剂应符合现行的产品质量标准。3.1.5发泡剂稀释倍数应按照相关产品说明书执行,发泡均匀,泡沫直径宜小于1.2mm,稳泡时间应大于30分钟。3.1.6现浇轻质泡沫混凝土浆料各组分用量应根据配合比设计确定,应确保料浆和泡沫充分混合均匀,保证其流动性和堆积高度。3.2配合比3.2.1现浇轻质泡沫混凝土配合比设计,应先配制水泥浆液,后计5算所需泡沫体积,将水泥浆和泡沫混合均匀后制得泡沫混凝土。3.2.2现浇轻质泡沫混凝土的配合比,应按设计容重来配制。3.2.3现浇轻质泡沫混凝土的配合比设计步骤宜符合下列规定:1单位体积现浇轻质泡沫混凝土水泥用量应按下式计算确定:mm812.0cm——拟配制泡沫混凝土单位体积的质量(㎏);cm——拟配制泡沫混凝土单位体积的水泥用量(㎏);2单位体积现浇轻质泡沫混凝土用水量按式计算确定cw227.0mmwm——拟配制泡沫混凝土单位体积的用水量(㎏);cm——拟配制泡沫混凝土单位体积的水泥用量(㎏);3单位体积现浇轻质泡沫混凝土泡沫体积按式计算确定wwCCP1mmVPV——拟配制泡沫混凝土泡沫体积(m3);cm——拟配制泡沫混凝土单位体积的水泥用量(㎏);wm——拟配制泡沫混凝土单位体积的用水量(㎏);C——水泥的表观密度(㎏/m3);w——水的密度(㎏/m3)。4配制现浇轻质泡沫混凝土应选择三个不同的配合比,其中一个为基准配合比,另外两个配合比的发泡剂用量分别增减1%,每个配合比各取3组试件检测,经试验检测其工作性能后确定最终施工配合比。63.3试验方法3.3.1水泥的取样频率和试验方法应按照《通用硅酸盐水泥》GB175执行。3.3.2发泡剂的取样频率宜按500㎏为一批次,不足500㎏按一批次计,不同生产厂家、品种、批号的发泡剂不得混合取样。3.3.3发泡剂的性能指标检测每批不少于1组。3.3.4用于检测发泡剂性能指标的泡沫应根据发泡剂的使用说明书进行配制。3.3.5泡沫的发泡倍数,1h的沉降距、泌水量,试验方法见附录A。74设计4.1一般规定4.1.1现浇轻质泡沫混凝土可在加工厂进行预加工或现场浇筑施工而成,其物理性能应符合表4.1.1要求。表4.1.1现浇轻质泡沫混凝土性能指标项目指标干体积密度(kg/m3)300400500600700800900抗压强度(Mpa)≥0.5≥0.7≥1.0≥1.5≥2.5≥3.5≥4.5导热系数[W/(m•K)]0.070.0850.100.120.140.180.22蓄热系数[W/(m•K)]3.424.064.70吸水率(%)16~2314~20燃烧性能不燃烧体注:1用于屋面、地面的现浇泡沫混凝土的导热系数修正系数α=1.5;2用于楼面的现浇泡沫混凝土的导热系数修正系数α=1.3。4.1.2现浇轻质泡沫混凝土为水泥基材料,适用现浇混凝土地面、楼面、屋面。对其他吸水率、渗透性较大的基面,则需作相应的处理。4.1.3用于现浇轻质泡沫混凝土保温层应保持干燥,封闭式保温层的含水率应小于该材料在当地自然风干状态下的平均含水率。4.2现浇轻质泡沫混凝土屋面保温层设计4.2.1现浇轻质泡沫混凝土屋面保温层厚度设计应根据所在地区按现行建筑节能设计标准计算确定,尚应符合《屋面工程技术规范》GB50345对不同类型屋面的要求。84.2.2保温层的设计,应根据建筑物的使用要求、屋面的结构形式、环境气候条件、防水处理方法和施工条件等因素确定。4.2.3有隔汽层要求的屋面结构,应先将基层表面进行处理,确保基层干净,平整、干燥,无松散、开裂起鼓等缺陷。4.2.4设计采用现浇轻质泡沫混凝土保温层时,防水层宜设置在保温层上部,具体构造如图4.2.4所示:图4.2.4现浇轻质泡沫混凝土屋面体系构造示意图1——结构层;2——隔汽层;3——泡沫混凝土保温层;4——砂浆找平层5——防水层;6——保护层;7——排气管4.2.5现浇轻质泡沫混凝土亦可应用于屋面找坡,坡度应符合设计要求,当设计无规定时,坡度宜为2%~3%。4.3现浇轻质泡沫混凝土地暖保温层设计4.3.1直接与土壤接触或有潮湿气体侵入的地面保温层下部必须设置防潮层,与空气相邻的楼板可直接铺设保温层。4.3.2保温层厚度应满足热工计算要求,在与土壤或不采暖房间相邻的地板上的厚度应不小于60mm;各楼层间楼板上部的现浇轻质泡沫混凝土保温层厚度应不小于40mm。具体构造见图4.3.2。9图4.3.2现浇轻质泡沫混凝土地暖保温层构造示意图1——填充层;2——泡沫混凝土保温层;3——结构层4——热水管;5——防潮层4.3.3对于潮湿房间如卫生间、洗衣间、浴室和游泳馆等有防水要求的应在现浇轻质泡沫混凝土保温层下部设防潮层,尚应在填充层上部设防水层。105施工5.1一般规定5.1.1现浇轻质泡沫混凝土所使用的主要材料应保持干燥,施工时要做好避雨、防潮措施。5.1.2施工前应检查基层质量,凡基层有裂缝、蜂窝的地方,应采用水泥砂浆进行封闭处理,及时清扫浮灰;天气干燥时,应先润湿基层,基层不得有明显积水。5.1.3原材料进场后,应按规定抽样复检,严禁在工程中使用不合格材料。5.1.4现浇轻质泡沫混凝土保温层施工应具有相关资质的
本文标题:现浇轻质泡沫混凝土应用技术规程
链接地址:https://www.777doc.com/doc-3765656 .html