1数字调速器原理操作说明书武汉三联水电控制设备有限公司二O一一年一月2目录第一部分数字调速器原理说明第一章水轮机调节.................................................4一.水轮机调节的基本任务.........................................4二.水轮机调节系统的结构.........................................4第二章水轮机调速系统的标准和特性...............................4一.水轮机调速系统的标准.........................................4二.调速器总体原则...............................................5三.性能指标.....................................................5四.调速系统的可靠性.............................................6第三章调节规律...................................................6第四章调速器系统组成.............................................9一PSW(S)T比例数字式冗余可编程控制水轮机调速器..................9二.BW(S)T水轮机调速器.........................................11三.SLT数字式水轮机调速器......................................13四冲击式(CJSTn/n)调速器......................................14五电气控制系统.................................................16六供电电源及监视...............................................17七主配压阀.....................................................17八滤油器.......................................................18第五章调速器的运行..............................................181.调速器运行流程...............................................192.自动运行工况.................................................203.电手动运行工况...............................................244.机械手动运行工况.............................................24第六章调速器的其他功能.........................................251浆叶协联函数发生器............................................252分段关闭装置..................................................253内置试验功能..................................................253第二部分数字调速器操作说明第一章面板操作说明..............................................28第二章触摸屏操作说明............................................291概述..........................................................292显示及操作....................................................293其他类型调速器主显画面举例....................................31第三章数字阀式(SLT)及冲击式(CJWT)系列机械部分操作说明.323.1开关机操作..................................................323.2开、关机时间调整............................................323.3紧急停机....................................................323.4说明........................................................323.5其他........................................................33第四章比例数字式PSW(S)T系列机械部分操作说明..............334.1开关机操作..................................................334.2机械零位调整................................................334.3开、关机时间调整及电气反馈整定..............................334.4紧急停机....................................................344.5比例数字切换阀..............................................34第五章步进式系列机械部分操作说明..............................345.1开关机操作..................................................345.2机械零点调整................................................345.3开、关机时间调整............................................355.4紧急停机....................................................355.5说明........................................................35第六章自动运行..................................................35第七章参数检查..................................................37第八章维护.......................................................388.1电气日常维护................................................388.2机械日常维护................................................38第九章故障处理..................................................399.1空载运行....................................................399.2负载运行....................................................399.3接力器......................................................409.4甩负荷......................................................409.5参数和水头..................................................419.6关键输入信号................................................419.7监视关键参数................................................424第一部分数字调速器原理说明第一章水轮机调节一.水轮机调节的基本任务水轮发电机组把水能转变为电能供生产、生活使用。用户在用电过程中除要求供电安全可靠外,对电网电能质量也有十分严格的要求。按我国电力部门规定,电网的额定频率为50Hz(赫兹),大电网允许的频率偏差为±0.2Hz。对我国的中小电网来说,系统负荷波动有时会达到其容量的5%~10%;而且即使是大的电力系统,其负荷波动也往往会达到其总容量的2%~3%。电力系统负荷的不断变化,导致了系统频率的波动。因此,不断地调节水轮发电机组的输出功率,维持机组的转速(频率)在额定转速(频率)的规定范围内,就是水轮机调节的基本任务。二.水轮机调节系统的结构水轮机调节系统是由水轮机控制设备(系统)和被控制系统组成的闭环系统。水轮机、引水和泄水系统、装有电压调节器的发电机及其所并入的电网称为水轮机调节系统的被控制系统;用来检测被控参量(转速、功率、水位、流量等)与给定量的偏差,并将其按一定的特性转换成主接力器行程偏差的一些装置组合成为水轮机控制设备(系统)。水轮机调速器则是由实现水轮机调节及相应控制的电气控制装置和机械执行机构组成。第二章水轮机调速系统的标准和特性一.水轮机调速系统的标准1.《电气与电气工程师协会标准》IEEE/IEC60362-1998;2.《水轮机电液调节系统及装置技术规程》DL/563-2004;3.《水轮机调速器与油压装置试验验收规程》GB/T9652.2-2007;4.《水轮机调速器与油压装置技术条件》GB/T9652.1-2007;5.《大中型水轮机组自动化元件及系统基本技术条件》GB/T11805-2008;6.IEC308《水轮机调速系统试验国际规程》;7.NEMA《美国电气制造商协会标准》。5二.调速器总体原则符合国家有关文件、标准的规定,充分体现先进性、合理性、完整性和高可靠性的原则。保证整个调速系统安全可靠地工作,并满足如下要求:*满足有关文件的要求和有关国家标准。*适应频繁启停,空载快捷平稳,大网运行安全可靠,小网运行响应迅速。*高性能和高安全可靠性。*各种运行工况稳定运行、相互跟踪、切换无扰动。*硬件配置合理,各种调节控制功能完备。*全中文图形、表格、数据的人机操作平台。*完善的试验、录波、事件记录、自诊断、帮助等辅助功能。*选用世界知名厂家的兼容性高的最新元器件。三.性能指标*导叶接力器全关闭时间调整范围为:3~100S*导叶接力器全开启时间调整范围为:3~100S*桨叶接力器全关闭时间调整范围为:10~120S*桨叶接力器全开启时间调整范围为:10~120S*频率调整范围:45~55Hz*永态转差bp调整范围:0~10%*比例增益Kp调整范围:0.5~20*积分增益KI调整范围:0.05~101/s*微分增益KD调整范围:0.0~10s*人工失灵区调节范围:0~±1.5%nr*测至主接力器的转速死区不超过:0.02%*水轮机甩25%负荷后,接力器不动时间不超过:0.2s*静特性曲线非线性度:不超过0.5%*自动空载运行3分钟,机组转速相对摆动值不超过+0.15%。*甩100%额定负荷后转速波动超过3%的波动次数不超过2次,由调速器引起
本文标题:三联数字调速器原理操作说明书合订本0014
链接地址:https://www.777doc.com/doc-3856531 .html