您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > 开利BFP变风量空气处理机组
产品制造公司:上海一冷开利空调设备有限公司通惠空调设备厂成都开利爱得瑞空调设备有限公司开利BFP(X)/BF/BFP-R空气处理机组风量:2000~50000m³/h(BFP)2000~36000m³/h(BF)1000~8000m³/h(BFP-R)N-BFP(X)/BF/BFP-R-1508-04开利中国销售机构上海(86-21)23063000北京(86-10)65540999成都(86-28)62122600西安(86-29)68725300广州(86-20)83931313苏州(86-512)62888120开利中国维修服务开利中国多得利零件业务(86)4009-000-888开利/你信赖的专家1998年,在美国《时代》杂志举行的20世纪最有影响力的100位风云人物的评选中,开利博士被评为其中的20位“建设伟人”之一。BFPX2IWSPZSPBFP:200050000m3/hBF:200036000m3/hBFP-R:1000~8000m3/h2型号说明风量包装形式P:PE缠绕膜包装无:木箱花格包装过滤器方向S:上下抽Z:左右抽机组进回水方向(以面对回风口来区分):右进水Z:左进水机组结构形式WSP:卧式上出风WSZ:卧式上出风WZS:卧式水平出风WZX:卧式水平出风LSP:立式上出风LQS:立式水平出风I:电机功率增大型(高静压)无:标准配置(额定静压)机组规格(风量数字m³/h)盘管排数X:高冷量盘管无:额定冷量盘管产品系列BFP:空气处理机组BF1位:过滤器抽出方向S:上下抽Z:左右抽1位:机组方向Y:右向Z:左向3位:机组结构形式WSP:卧式上出风WSZ:卧式上出风WZS:卧式水平出风WZX:卧式水平出风0~1位:改型代号I:电机功率增大型(高静压)无:标准配置(额定静压)1~2位:机组规格(风量=数字1000m³/h)风机箱生产商THC:上海一冷开利通惠工厂产品设计记录0:原始设计控制C:带控制(配合VWV系统使用)缺省:无控制机组方向L:左向机组R:右向机组电源A:380V-3Ph-50Hz盘管排数2:2排盘管4:4排盘管排风出口全压L:低H:高送风出口全压L:低H:高能量回收(板式全热型)机组规格(风量=数字1000m³/h)BFP:热回收新风空气处理机组BFP1RHH2ARC0THC机组特点性能优越的表冷器过滤器安装方便,利于维修箱体特点送风机特点43采用低噪声、外转子离心风机,具有体积小、噪声低等特点。BFP(X)/BF机组当配上电机变频器后,可实现风机变速,达到机组变风量要求,以匹配空调系统的四季节能运行。铝合金框架结构,模块化设计。双层面板,外层采用PE彩钢板,外观美、寿命长;内层采用优质镀锌钢板,防锈防蚀。中间充填聚氨酯发泡保温材料,保温性能良好且强度坚固。机组装有活动检修门,便于日常维修保养。BFP(X)空气处理机组和BF风机箱是开利采用先进技术改进发展的新型产品,具有外形美观、性能优越、质量可靠、可变风量的特点,更具有机组低噪音、拆装方便等优势。广泛应用于工厂、宾馆、大厦、剧场、医院、机场、工矿企业及科研单位等。BFP系列产品根据对空气处理的基本要求而设计制造,具有过滤、盘管、送风机等基本功能段。并可非标选配2排热水盘管、湿膜加湿器、不锈钢水盘,变频控制柜等选项。BF系列产品是根据BFP系列简化而来,只有过滤、风机功能段,是通风工程中常用的风机箱。热回收新风空气处理机组与空调系统配合使用可增加室内空气的新鲜度,保持室内空气的温、湿度要求,减少新风负荷、降低空调设备的容量和日常运行费用,并且达到空气净化和节能的双重目的。BFP-R热回收新风空气处理机组,采用透湿率高、热阻低、强度高的空气——空气热交换器和低噪音离心风机,具有高效节能和舒适静音的特点,广泛适用于办公室、会议厅、展览馆、影剧院、宾馆、医院、住宅、公寓等场所。BF/BFP(X)BFP-R箱体结构外转子离心风机采用开利最新翅片,传热效率高。其主体由优质铜管和铝箔经机械涨管而成,并经2.8Mpa气压检测实验,合理的过盈设计使其性能优越,质量可靠。冷热盘管滤料为锦纶凹凸网,清洗与更换方便,安装形式有上抽、下抽、左抽和右抽。BFP(X)系列产品有立式和卧式两种结构形式。除基本功能外,还可根据用户要求增加热水或蒸汽加热、湿膜加湿功能,也可另配温湿度及风量调节控制系统。机组结构合理,外形美观、性能优异、质量可靠,由于采用先进的数控机床加工设备,零部件的互换与组合质量得以充分保证,便于现场拆装。箱体内部过滤网65BFP性能参数BFPX)性能参数BFP2BFP2IBFP3BFP3IBFP4BFP4IBFP5BFP5IBFP6BFP6IBFP7.5BFP7.5IBFP8BFP8IBFP9BFP9IBFP10BFP10IBFP12BFP12IBFP15BFP15IBFP16BFP16IBFP18BFP18IBFP22BFP22IBFP24BFP24IBFP27BFP27IBFP30BFP30IBFP36BFP36IBFP40BFP45BFP50200020003000300040004000500050006000600075007500800080009000900010000100001200012000150001500016000160001800018000220002200024000240002700027000300003000036000360004000045000500000.370.550.550.80.81.81.11.80.552.21.83.00.81.82.21.81.11.80.84.01.11.81.83.02.23.01.83.04.04.02.23.04.03.04.04.05.57.57.50.540.800.751.111.102.611.512.610.752.932.403.851.102.612.892.611.512.611.104.881.512.612.403.852.893.802.403.854.884.882.893.804.883.804.884.886.558.938.9311111111211122122231322222332233333333311.25*17.1223.6528.5034.2043.1245.6651.3055.9068.4016.3024.7034.3042.8050.4064.2067.6074.8085.60103.00123.00136.00151.00183.00202.00230.00251.00300.002.4011.309.0011.6014.2033.1035.6037.3039.701.903.244.685.405.768.288.649.2010.4023.0133.0145.1556.4467.7381.87*93.46*105.2*116.8*26.0037.4049.2063.1073.7092.80103.00118.00124.00147.00164.00204.00232.00260.00284.00314.00377.00447.0013.1042.7034.2044.3054.1072.6074.5037.3079.504.326.489.7211.1612.2413.3214.0416.7018.20155320145230235535230430145485355595205505355575180380235460215330235525315510345610190/130450/390315/260520/465255/190510/445200/130490/420460515465400470285380380690380660285630500740380690455690380660380620380500390740455670500740415620455670480670415620570810780200220260270320380390410420470650670690820840850900110055.056.557.063.058.064.061.565.059.567.067.072.561.067.069.068.563.068.062.069.065.069.066.573.071.067.571.076.571.075.073.069.577.074.075.079.076.077.078.01802002302402703503603803904105906206407808008108601000机组型号风量电机额定功率电机输入功率标准工况新风工况额定冷量额定热量水阻水量机组重量kg立式卧式m³/hkWkW风机台数nkWkWkPaT/h额定冷量额定热量水阻水量kWkWkPaT/h机外静压Pa机组全静压Pa噪声dB(A)82.5082.5*92.30102.60125.40134.40151.20186.10201.60221.00253.00283.00395.00453.00507.0021.4051.0017.4054.5025.4029.2030.2019.9029.6043.3046.8026.6036.9040.2012.6012.6014.7612.9617.2818.7223.0423.4027.3633.4836.1038.0043.4048.70135.50135.5*153.70153.7*187.5*210.9*240*260*292.5*351*411*451*477*535*500.00560.00625.0071.9069.2056.4075.0060.0060.9060.3062.5064.3072.2075.6088.0074.0081.0024.4815.1227.3616.2027.3627.3634.2043.9242.1244.6448.3065.0058.0065.00110012551360冷量带*表示水温差非5℃标准工况:制冷:进风干球温度27℃,进风湿球温度19.5℃;冷水进水温度7℃,出水温度12℃制热:进风干球温度15℃;热水进水温度60℃,出水温度50℃新风工况:制冷:进风干球温度35℃,进风湿球温度28℃;冷水进水温度7℃,出水温度12℃制热:进风干球温度7℃;热水进水温度60℃,出水温度50℃注:1.电机输入功率是指单台电机的输入功率2.表冷器盘管为额定冷量盘管3.机外静压前面数据为卧式机组/后面为立式机组BFPX2BFPX2IBFPX3BFPX3IBFPX4BFPX4IBFPX5BFPX5IBFPX6BFPX6IBFPX7.5BFPX7.5IBFPX8BFPX8IBFPX9BFPX9IBFPX10BFPX10IBFPX12BFPX12IBFPX15BFPX15IBFPX16BFPX16IBFPX18BFPX18IBFPX22BFPX22IBFPX24BFPX24IBFPX27BFPX27IBFPX30BFPX30IBFPX36BFPX36IBFPX40BFPX45BFPX50200020003000300040004000500050006000600075007500800080009000900010000100001200012000150001500016000160001800018000220002200024000240002700027000300003000036000360004000045000500000.370.550.550.80.81.81.11.80.552.21.83.00.81.82.21.81.11.80.84.01.11.81.83.02.23.01.83.04.04.02.23.04.03.04.04.05.57.57.50.540.800.751.111.102.611.512.610.752.932.403.851.102.612.892.611.5
本文标题:开利BFP变风量空气处理机组
链接地址:https://www.777doc.com/doc-4524087 .html