某纺织厂供配电系统设计班级:15电气二班学号:姓名:2017年月日目录序、题目....................................................................................................3一、各车间的负荷计算............................................................................5二、供电电压和初步方案确定................................................................7三、车间供电系统的设计........................................................................9四、变电所主变压器的选择及主接线说明..........................................12五、短路电流的计算..............................................................................13六、设备的选择与校验..........................................................................18七丶导线的选择......................................................................................22八、主接线图及器件汇总......................................................................23题目2某纺织厂供配电系统设计一.原始资料1.工厂负荷数据:工厂多数车间为2班制,年最大负荷利用小时数4600小时。工厂负荷统计资料见表1。设计需要考虑工厂5年发展规划负荷(工厂负荷年增长率按2%)。表1:化纤厂负荷情况表序号车间及设备安装容量(kW)需要系数dKtg1纺练车间纺丝机2000.800.78筒绞机300.750.75烘干机850.751.02脱水机120.600.80通风机1800.700.75淋洗机60.750.78变频机8400.800.70传送机400.800.702原液车间照明10400.750.703酸站照明2600.650.704锅炉房照明3200.750.755排毒车间照明1600.700.606其他车间照明2400.700.752.供电电源请况:按与供电局协议,本厂可由16公里处的城北变电所(110/38.5/11kV),90MVA变压器供电,供电电压可任选。另外,与本厂相距5公里处的其他工厂可以引入10kV电缆做备用电源,但容量只能满足本厂负荷的20%(重要负荷),平时不准投入,只在本厂主要电源故障或检修时投入。3.电源的短路容量(城北变电所):35kV母线的出线断路器断流容量为400MVA;10kV母线的出线断路器断流容量为350MVA。4.电费制度:按两部制电费计算。变压安装容量每1kVA为18元/月,电费为0.5元/kW·h。5.气象资料:本厂地区最高温度为38度,最热月平均最高气温为30度。6.地质水文资料:本厂地区海拔60m,底层以砂粘土为主,地下水位为2m。二.设计内容1.总降压变电站设计(1)负荷计算(2)主结线设计:根据设计任务书,分析原始资料与数据,列出技术上可能实现的多个方案,根据改方案初选主变压器及高压开关等设备,经过概略分析比较,留下2~3个较优方案,对较优方案进行详细计算和分析比较,(经济计算分析时,设备价格、使用综合投资指标),确定最优方案。(3)短路电流计算:根据电气设备选择和继电保护的需要,确定短路计算点,计算三相短路电流,计算结果列出汇总表。(4)主要电气设备选择:主要电气设备的选择,包括断路器、隔离开关、互感器、导线截面和型号、绝缘子等设备的选择及校验。选用设备型号、数量、汇成设备一览表。2.车间变电所设计根据车间负荷情况,选择车间变压器的台数、容量,以及变电所位置的原则考虑。3.厂区380V配电系统设计根据所给资料,列出配电系统结线方案,经过详细计算和分析比较,确定最优方案。三.设计成果1.设计说明书,包括全部设计内容,负荷计算,短路计算及设备选择要求列表;2.电气主接线图(三号图纸);答疑地点:13-15周周五上午:9;00-11;00,下午:3:00-17;00,机电实验大楼A226参考文献:1、翁双安主编,《供配电工程设计指导》[M],机械工业出版社2、刘介才,工厂供电设计指导[M],机械工业出版社一、各车间的负荷计算1.纺练车间①纺丝机:160(kW)=0.80×2001.30NdPKPvar)(8.12478.0160tan301.30kPQ②筒绞机:)(5.2275.0302.30kWPKPNdvar)(9.1675.05.22tan302.30kPQ③烘干机:)(8.6375.0853.30kWPKPNdvar)(0.6502.175.63tan303.30kPQ④脱水机:)(2.76.0124.30kWPKPNdvar)(8.58.02.7tan304.30kPQ⑤通风机:)(1267.01805.30kWPKPNdvar)(5.9475.0126tan305.30kPQ⑥淋洗机:)(5.475.066.30kWPKPNdvar)(5.378.05.4tan306.30kPQ⑦变频机:)(6728.08407.30kWPKPNdvar)(4.4707.0672tan307.30kPQ⑧传送机:)(328.0408.30kWPKPNdvar)(4.227.032tan307.30kPQ车间总计算负荷对于车间负荷系数取K∑P=0.95K∑q=0.97kW1033.6=32)+672+4.5+126+7.2+63.8+22.5+(160×0.9581.301iipPKPkvar)779.3(=22.4)+470.4+3.5+94.5+5.8+65.0+16.9+(124.8×0.9781.301kkqQKQ)(3.12943.7796.10332221211AkVQPS)(97.138035.1294311kAUSIN2.原液车间照明:)(78075.010402kWPKPNdvar)(5467.0780tan22kPQ总的计算负荷)(1.9525467802222222AkVQPS)(45.1380311.952322kAUSIN3.酸站照明:)(16965.02603kWPKPNdvar)(3.1187.0169tan33kPQ总的计算负荷,)(3.2063.1181692223233AkVQPS)(31.0380330.206333kAUSIN4.锅炉房照明:)(24075.03204kWPKPNdvar)(18075.0240tan44kPQ总的计算负荷,)(3001802402224244AkVQPS)(46.03803300344kAUSIN5.排毒车间照明:)(1127.01605kWPKPNdvar)(2.676.0112tan55kPQ总的计算负荷,)(6.1302.671122225255AkVQPS)(20.0380361.130355kAUSIN6.其他车间照明:)(1687.02406kWPKPNdvar)(12675.0168tan66kPQ总的计算负荷,)(2101261682226266AkVQPS)(32.03803210366kAUSIN(注:最后一页附表1为各车间计算负荷统计)对于全厂负荷系数,取K∑P=0.90K∑q=0.9561)(3.2252)1681122401697806.1033(9.0iipkWPKP61var)(8.1726)1262.671803.1185463.779(95.0kkqkQKQ)(5.28370.17263.22522222kVAQPS)(81.463536.28373AUSIN考虑5年的发展,年增长率按2%计算,全厂计算负荷)(7.2486%)21(3.22525'kWPvar)(6.1905%)21(0.17265'kQ)(3132.96.19057.2486222'2''kVAQPS二、供电电压和初步方案确定①电压等级的确定工厂供电的电压,主要取决于当地电网的供电等级,同时也要考虑工厂用电设备的电压、容量和供电距离等因素。题目提供了三个电压等级:110/38.5/11kV。由计算可知五年后工厂的最大功率为2486.7kW,且输送距离为16km。查《工厂供电》表1-3可知,选用线路电压35kV,输送功率2000~10000kW,输送距离在20~50km。然后再从与本厂相距5公里处的其他工厂引入10kV电缆做备用电源。②供电方式的确定初步确定为两种方案:(1)如果当地电网供电电压为35kV,而厂区环境条件又允许采用35kV架空线和较经济的35kV电气设备时,可考虑采用35kV作为高压配电电压深入工厂各车间负荷中心,并经车间变电所直接降为低压用电设备所需电压。(2)设立一个主降压变电,工作电源采用35kV,由变电所引入一回架空线路,备用电源采用10kV电压,由其他工厂引入一回架空线路。对于只有二级负荷而无一级负荷的变电所,可以只采用一台变压器,但必须另有备用电源,所以仅需一台主变压器即可,10kV侧仍采用单母线分段的主接线,正常时由主变压器供电,故障时由10kV备用电源供电。方案一优点:供电电压高,线路功率损耗少。电压损失小,调压问题容易解决。要求的功率因数值低,所需补偿容量小,可减少投资。缺点:需要的厂区环境比较严格方案二优点:方案既能满足供电可靠性的要求,投资也相对较少;设立了总变电所,便于工厂供电系统的集中管理和调度缺点:设立总变电所,占地面积较多。且所需的主变压器容量太大,可考虑用两台容量低的变压器并列运行(注:技术发展,现在支持大容量的变压器)③选择方案二正常时以35kV单回架空线路供电,由于工厂的计算负荷kVAS3132.9'(以五年后计算),考虑设一台变压器,选取主变压器容量为kVASN3150,型号为SL7-3150/35。其电压比为kV5.10/35,主要技术参数如下:WPk75.40,kWPK27,2.1%I,7%KU。正常运行时变压器的负荷率为:995.031509.3132β则主变压器的有功功率为:kWPPPKT48.31995.02775.4220无功功率为:var1.256)7995.02.1(1003150%)%(10022kUISQKNT工厂进线的计算负荷:kWP2.251848.317.2486''30var7.21611.2566.1905''30kQ)(8.31837.21612.251822''30kVASAI7.543538.33180.976.08.33182.2518cos功率因数不满足要求,需要进行补偿var6.922)84.25tan54.40(tan7.2486)tan(tan'''kPQ选用BWF10.5-100-1W的并联电容进
本文标题:某纺织厂供配电系统设计
链接地址:https://www.777doc.com/doc-5412102 .html