您好,欢迎访问三七文档
毕业设计说明书(08级)110KV/35KV变电所设计学生姓名学号院系工学院机电系专业自动化指导教师完成日期-2-110KV/35KV变电所设计摘要变电所是电力系统的重要组成部分,它直接影响整个电力系统的安全与经济运行,是联系发电厂和用户的中间环节,起着变换和分配电能的作用。这次设计以110kV降压变电所为主要设计对象,分析变电站的原始资料确定变电所的主接线;通过负荷计算确定主变压器台数、容量及型号。根据短路计算的结果,对变电所的一次设备进行了选择和校验。同时完成防雷保护及接地装置方案的设计。关键词:电气主接线;短路电流;继电保护;直流系统;防雷接地-3-110KV/35KVsubstationdesignAbstractSubstationistheimportantpartofpowersystem,itdirectlyinfluencesthewholepowersystemsafeandeconomicoperationofthepowerplantandtheuser,istheintermediatelink,playsaroleintransformationanddistributionofelectricity.Thedesign110kVsubstationasthemaindesigntarget,analysisoftheoriginaldatatodeterminesubstationsubstationmainwiring;throughloadcalculationtodeterminethemaintransformernumber,capacityandtype.Accordingtotheshortcircuitcalculationresults,forasubstationofanequipmentselectionandcheck.Atthesametimethelightningprotectionandgroundingdevicedesign.Keyword:mainelectricalconnection;short-circuitcurrent;relayprotection;DCsystem;grounding-4-目录前言........................................................................................................................-5-一、原始资料分析...................................................................................................-5-1.1本所设计电压等级....................................................................................-5-1.2电源负荷地理位置情况............................................................................-5-二、电气主接线设计...............................................................................................-7-2.1主接线接线方式........................................................................................-7-2.3电气主接线的选择....................................................................................-9-三、所用电的设计.................................................................................................-10-3.1所用电接线一般原则...............................................................................-11-3.2所用变容量型式的确定...........................................................................-11-3.3所用电接线方式确定...............................................................................-11-3.4备用电源自动投入装置...........................................................................-11-四、短路电流计算.................................................................................................-13-4.1短路计算的目的......................................................................................-13-4.2短路计算过程..........................................................................................-13-五电气设备选择....................................................................................................-23-5.1、电气设备选择的一般原则...................................................................-23-5.2、按正常工作条件选择导体和电器.......................................................-24-5.3、电气设备的选择原则...........................................................................-25-六、继电保护配置.................................................................................................-31-6.1、系统继电保护及自动装置...................................................................-31-6.2、继电保护配置原则...............................................................................-32-6.3、110千伏系统........................................................................................-32-6.4、主变压器保护.......................................................................................-32-七、直流系统.........................................................................................................-33-八、防雷接地........................................................................................................-33-8.1避雷器的选择..........................................................................................-34-8.2变电所的进线段保护...............................................................................-34-8.3接地装置的设计......................................................................................-35-设计总结.....................................................................................................................38参考文献:.................................................................................................................39致谢.............................................................................................................................40-5-前言本次设计题目为110KV/35K变电所设计。此设计任务旨在体现对本专业各科知识的掌握程度,培养对本专业各科知识进行综合运用的能力,同时检验本专业学习四年以来的学习结果。此次设计首先根据任务书上所给系统与线路及所有负荷的参数,分析负荷发展趋势。通过对拟建变电站的概括以及出线方向来考虑,并通过对负荷资料的分析,安全,经济及可靠性方面考虑,确定了110kV主接线,然后又通过负荷计算及供电范围确定了主变压器台数,容量及型号,同时也确定了站用变压器的容量及型号,在根据最大持续工作电流及短路计算结果,对设备进行了选型校验,同时考虑到系统发生故障时,必须有相应的保护装置,因此对继电保护做了简要说明。对于来自外部的雷电过电压,则进行了防雷保护和接地装置的设计,最后对整体进行规划布置,从而完成110kV变电所一次系统的设计。一、原始资料分析1.1本所设计电压等级根据设计任务本次设计的电压等级为:110/35KV1.2电源负荷地理位置情况1、电源分析与本所连接的系统电源共有3个,其中110KV两个,35KV一个。具体情况如下:1)110KV系统变电所该所电源容量(即110KV系统装机总容量)为200MVA(以火电为主)。在该所等电压母线上的短路容量为650MVA,该所与本所的距离为9KM。以一回路与本所连接。2)110KV火电厂该厂距离本所12KM,装有3台机组和两台主变,以一回线路与本所连接,-6-该厂主接线简图如图1.1:图1.1110KV火电厂接线图3)35KV系统变电所该所距本所7.5KM.以一回线路相连接,在该所高压母线上的短路容量为250MVA.。以上3个电源,在正常运行时,主要是由两个110KV级电源来供电给本所。35KV变电所与本所相连的线路传输功率较小,为联络用。当3个电源中的某一电源出故障
本文标题:电气自动化毕业设计
链接地址:https://www.777doc.com/doc-5941457 .html