您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 项目/工程管理 > 富盈暖通空调设计统一技术措施
富盈地产暖通空调设计统一技术措施富盈集团地产•设计文件标准文本1目录一、系统分类及设备材料选型·············································································21系统分类·····························································································22设备材料选型······················································································2二、设计要求···································································································21防排烟(通风)系统·············································································21.1通风排烟系统···················································································31.2加压送风系统···················································································31.3排烟系统··························································································42空气调节系统······················································································42.1分体空调··························································································42.2小型中央空调···················································································52.3大、中型中央空调系统·······································································73采暖系统·····························································································84燃气供应·····························································································9富盈集团地产•设计文件标准文本2所有设计、配置方案应报集团设计中心及成本合约中心审批。在满足设计要求的前提下,以经济为原则。一、系统分类及设备材料选型1系统分类1.1系统分类:防排烟(通风)系统、空气调节系统、采暖系统、燃气供应。1.2商场、办公写字楼、宾馆酒店、汽车库、地下室、人防等凡所涉的通风、防排烟、空调风管各系统如能按共用系统合并时均不得独立设置。1.3较大型公共厨房的排风系统、进风系统、抽油烟及净化过滤系统和满足防排烟设置要求时的排烟系统、需设空调时的空调系统、冷库系统等,建筑设计单位可不出图或缓出图,但建筑设计单位应事先征得我设计中心相应专业主管工程师的书面认可,且应承担以后相关专业公司所作相关设计的设计审查和设计配合的责任和义务,而当我司有要求时应允许其它相关单位套用建筑设计单位的图框并应负责加盖建筑设计单位的图章。2设备材料选型2.1防排烟(通风)风机优先采用噪音较低的柜式离心风机(小风量可采用轴流风机),排烟风机应保证在280℃时能连续工作30min。风量、风压的设计余量不应过大。2.2分体空调、小型中央空调厂家由集团确认。2.3地下室防排烟(通风)风管采用镀锌钢板。2.4小型中央空调系统冷凝水管采用PVC管,冷媒管、冷凝水管保温材料采用难燃B1级发泡橡塑管壳。穿梁和剪力墙的套管采用国标普通焊接钢套管,穿墙套管采用塑料套管。低温地板辐射采暖热水管采用PE-RT管。二、设计要求1防排烟(通风)系统富盈集团地产•设计文件标准文本31.1通风排烟系统1.1.1所有设备用房均要求设置机械式通风设施,在设计时不得遗漏。1.1.2设备用房所设置的机械式通风设施应优先考虑采用轴流风机或换气扇直接排或进风,而当必须采用风管通风系统时方可按风管通风系统设计。1.1.3卫生间无论建筑窗是否直通室外都均应设计机械排风设施。1.1.4在建筑上所涉生活、办公等人们经常活动场所的通风进或排风口处应有防虫措施。1.1.5室内风口的布置应强调气流的均匀分布,不得出现明显的通风死角和气流短路现象。1.1.6地下室风机房净高不小于3.5m,风机房应设置在墙柱较多、无法布置车位的位置,且应便于设送排风竖井,单台风机房的尺寸原则上为3.5×3.5m,多台风机的风机房的面积根据实际情况定。风机房门的尺寸应满足风机安装和检修时能进、出的要求。1.1.7地下室主风管风速可适当放大,以便减小风管尺寸,增加地下室净高。排风(烟)主风管推荐风速10-12m/s,送风主管推荐风速8-10m/s。1.1.8地下室设备用房与车库排风(排烟)系统宜分开设置。1.1.9通风换气量标准:项目房间名称换气次数(次/时)备注发电机房及储油间4补风量为大于排风量的50%汽车库6高压配电房15~20低压配电房20~25水泵房8~10公共卫生间10~15注:上表的发电机房的换气次数为平时换气次数,排除余热所需的排风量和燃烧空气量采用发电机厂商提供的数据。1.2加压送风系统1.2.1前室加压风井应靠近前室,风井有一面邻前室的墙(最好为非剪富盈集团地产•设计文件标准文本4力墙),以便设加压风口。1.2.2防烟楼梯间的加压风井应靠近防烟楼梯间,风井有一面邻防烟楼梯间墙(最好为非剪力墙),以便设加压风口。1.2.3加压送风井最小面积可按下表确定:防烟楼梯间加压前室不加压防烟楼梯间及其合用前室分别加压防烟楼梯间采用自然排烟前室或合用前室加压消防电梯间前室加压防烟楼梯间加压送风井面积防烟楼梯间加压送风井面积前室加压送风井面积前室或合用前室加压送风井面积消防电梯间前室加压送风井面积12层0.55m20.35m20.40m20.70m20.50m218层0.65m20.45m20.50m20.85m20.65m225层0.75m20.45m20.55m20.85m20.70m230层0.85m20.55m20.70m20.90m20.85m2注:(1)上表加压送风的风量是按单扇门为依据确定的,前室考虑有两个以上出入口,楼梯间考虑一个出入口。(2)如防烟楼梯为剪刀楼梯,且剪刀楼梯合用一个前室时,两座楼梯应分别设加压送风井。(3)上表数据仅适用于≤32层(含地下室)的加压送风系统。1.2.4加压风口安装高度为下底边距地500mm。1.2.5加压送风系统的风井应要求建筑专业在其设计说明中和在相关的平面图、大样图中均需明确“风井内壁应用水泥砂浆抹平”。1.3排烟系统1.3.1排烟井应靠近内走廊,排烟井有一面邻走廊的墙(最好为非剪力墙),以便设排烟口。1.3.2排烟口位置及形式应配合装修要求,可设于天花上,也可设于靠近天花(楼板)的墙面上,设于墙面时排烟口安装高度为上边距楼板100mm。2空气调节系统2.1分体空调2.1.1设置的分体空调为冷暖型。2.1.2室外机位应考虑必要的安装、维修及进、出风空间。富盈集团地产•设计文件标准文本52.1.3分体空调制冷量、适用面积详见下表。制冷量(W)普通房间(m2)客厅、饭厅(m2)一般办公室(m2)商场(m2)会议室、茶座(m2)小1匹220010~157~1111~15——1匹250012~178~1313~1710~146~9小1.5匹320015~2110~1516~2113~187~111.5匹350016~2312~1818~2314~198~12小2匹460021~3115~2323~3118~2610~152匹510024~3417~2626~3420~2812~172.5匹610029~4120~3131~4124~3414~203匹720034~4824~3636~4829~4017~245匹12000—40~6055~7548~6728~402.1.4凡属我司自用的会所、销售场所等应尽量采用房间空调器(分体空调),但当需要设置空调处的面积或空间较大时也可酌情考虑采用电动压缩式冷水机组(风冷涡旋式)或户用空调机组,而事先应征得我设计中心相应专业主管工程师的书面认可。2.2小型中央空调2.2.1设置小型中央空调范围:2.2.1.1户内部分:别墅、叠式别墅、高层空中花园洋房、复式花园洋房及情景洋房;2.2.1.2首层大堂:超豪华户型及夏热冬暖、夏热冬冷地区的豪华户型。2.2.2设置的小型中央空调为冷暖型。2.2.3室外机:2.2.3.1住宅首层大堂空调室外机位置应符合以下原则:①优先摆放于竖向百页或开口天井内;②其次摆放于住宅裙楼顶隐蔽处;富盈集团地产•设计文件标准文本6③同时不应对邻近住宅产生较大干扰和影响。2.2.3.2住宅空调室外机位应考虑必要的维修及进、出风空间,需预留人员检修通道300mm宽,检修位不小于400mm宽,并应预留安装通道;2.2.4冷媒管、冷凝水管管线布置2.2.4.1配有冷凝水泵的空调室内机的冷凝水管原则上穿梁铺设,局部位置梁高较低难以预留穿梁套管,且不影响装修高度时,可在梁下铺设。2.2.4.2不配有冷凝水泵的空调室内机的冷凝水管在梁下铺设。冷凝水管的走向应配合装修,局部位置如梁下净空较低,满足不了装修要求,应考虑穿梁或剪力墙。2.2.4.3冷媒管穿梁铺设,管中心距板底100mm。2.2.4.4冷媒管、冷凝水管均应定位,穿梁、墙和剪力墙套管均应标注标高。2.2.4.5别墅冷凝水原则上应统一收集排放至空调室外机附近的散水上;多层或高层住宅冷凝水统一收集至空调室外机位置或附近卫生间管井设立管排放。2.2.5室内机2.2.5.1空调室内机出风形式宜采用侧出风;2.2.5.2餐厅、客厅的空调室内机应避开中间天花凹池位置布置;2.2.5.3卧室空调室内机宜布置在入门口处,回风口注意避开衣柜;2.2.5.4如有两层通高的客厅(如别墅、复式住宅),空调室内机宜布置在下层;2.2.5.5设置空调区域详见下表:住宅别墅客厅设设餐厅设设卧室设设富盈集团地产•设计文件标准文本7书房设设带书房的衣帽间设设厨房、工人房严寒、寒冷、温和地区不设严寒、寒冷、温和地区不设夏热冬冷、夏热冬暖地区设夏热冬冷、夏热冬暖地区设起居室—设健身房—设家庭影院—设2.2.6应对各空气调节区进行逐项逐时冷负荷计算。现将经逐项逐时冷负荷计算,总结出广东地区空调房间冷负荷经验估算指标列表如下,供夏热冬暖地区、夏热冬冷地区设计时参考:工程类别序号名称分类夏季室内温度(℃)冷负荷指标(W/m2)住宅类1公寓、住宅标准层26~28150~180顶层、西晒、两面外墙26~28180~2202别墅一面外墙卧室26~28150~200两面外墙卧室26~28180~250顶层房间26~28200~350餐厅、客厅26~28200~3002.3大、中型中央空调系统2.3.1大、中型中央空调的设计应根据建筑物的性质,在充分进行技术经济分析后,由我司来确定其具体的配置要求,而建筑设计单位应负责按其要求设
本文标题:富盈暖通空调设计统一技术措施
链接地址:https://www.777doc.com/doc-6179330 .html