您好,欢迎访问三七文档
当前位置:首页 > 电子/通信 > 综合/其它 > 电子发烧友网用户转至网络
○○五年三月································································································································1第二章引用标准························································································································1第三章设备的验收····················································································································2第四章运行巡视、检查项目维护及要求·················································································4第五章事故和故障处理············································································································6第六章设备技术管理················································································································78第七章备品备件管理··············································································································9第八章设备报废··················································································································1072.5kV及以上电压等级支柱瓷绝缘子运行规范编制说明·······················································11,进一步拓宽运行管理工作的范围,延伸运行管理工作的内涵,保证设备安全、可靠、经济运行,特制定本规定。第二条本规定是依据国家、行业的有关标准、规程和规范并结合近年来国家电网公司输变电设备评估分析、生产运行情况分析以及设备运行经验而制定的。第三条本规定明确了高压支柱瓷绝缘子设备选型、订货、监造、出厂验收、现场安装、验收、运行、检修和设备的缺陷检测、评估、分析、过程工作提出了具体要求。第四条本规定适用于国家电网公司系统所辖发电厂、变电站、换流站、串补站,户内和户外72.5kV及以上电压等级的支柱瓷绝缘子的管理。第五条各网省电力公司可根据本规定,结合本地区实际情况制定相应的实施细则。第二章引用标准第六条以下为本规范引用的标准、规程和导则,但不限于此。GB/T494-1998建筑石油沥青GB772-1987高压支柱瓷绝缘子瓷件技术条件GB/T775.1-1987绝缘子试验方法第1部分:一般试验方法GB/T775.2-1987绝缘子试验方法第2部分:电气试验方法GB/T775.3-1987绝缘子试验方法第3部分:机械试验方法GB/T5582-1993高压电力设备外绝缘污秽等级GB8287.1-1998高压支柱瓷绝缘子第一部分:技术条件GB/T8287.2-1999高压支柱瓷绝缘子第二部分:尺寸与特性GB8411.1-1987电瓷材料第一部分:定义、分类和性能GB12744-1991耐污型户外棒形支柱瓷绝缘子GB/T16434-1996高压架空线路和发电厂、变电所环境污区分级及外绝缘选择标准GB/T16927.1-1997高电压试验技术第一部分一般试验要求JB4307-1986绝缘子胶装用水泥胶合剂技术条件JB/T5889-1991绝缘子用有色金属铸件技术条件JB/T5891-1991绝缘子用黑色金属铸件技术条件(内部使用)IEC600815耐污秽绝缘子的使用导则国家电网公司变电站管理规范(试行)国家电网公司高压支柱瓷绝缘子运行管理规范国家电网公司高压支柱瓷绝缘子技术监督规定国家电网公司预防高压支柱瓷绝缘子事故措施第三章设备的验收第七条新设备验收的项目及要求(一)设备运抵现场、安装前的验收(1)检查包装箱是否破损、受潮、制造厂家、产品名称及型号是否与所订购产品一致。(2)随产品提供的包装清单、产品合格证明书、安装使用说明书是否完整。(3)检查支柱瓷绝缘子的例行试验结果是否合格。(4)检对照包装清单检查备品附件是否缺少或损坏。(5)检查支柱瓷绝缘子的外观和铭牌是否缺少或损坏,支柱瓷绝缘子瓷裙是否完好。(6)支柱瓷绝缘子探伤检测。(二)支柱瓷绝缘子的安装后的验收(1)安装单位应具有规定的资质,安装人员必须经过培训,确保安装质量。(2)要明确安装技术要求,同时,安装人员必须熟练掌握技术要求,安装、调试必须严格按安装技术规范、安装使用说明书进行,尺寸、位置调整准确,避免存在安装应力。(3)工程监理部门要对设备安装过程进行监督,确保安装符合工艺要求,并做好监理记录。(4)安装、调试完成后,必须按验收标准进行验收。(三)验收和审批(1)验收的条件:1)安装完毕;2)相关试验合格,施工图、各项调试或试验报告、监理报告等技术资料和文件整理完毕;)预验收合格,缺陷已消除;场地已清理干净。(2)验收的要求和内容:1)项目负责单位应在工程竣工前十五天通知有关单位准备工程竣工验收,并组织相关单位参加,监理单位配合;2)验收单位应组织验收小组进行验收。在验收中检查发现的施工质量问题,应以书面形式通知相关单位并限期整改。验收合格后方可投入生产运行;3)在投产设备保质期内发现质量问题,应由建设单位负责处理。(3)审批:验收结束后,将验收报告交启动委员会审核批准。第八条设备验收的项目、内容及要求(一)检修设备、更换设备验收的项目和要求1检修设备验收的项目及要求(1)检查高压支柱瓷绝缘子瓷裙、基座及法兰是否有裂纹。(2)检查高压支柱瓷绝缘子结合处涂抹的防水胶是否有脱落现象,水泥胶装面是否完好。(3)检查高压支柱瓷绝缘子各连接部位是否有松动现象,金具和螺栓是否锈蚀。(4)检查高压支柱瓷绝缘子是否倾斜及各连接部位是否受力。(5)是否按周期进行超声波检测且检测结果。2更换设备验收的项目及要求(1)检查高压支柱瓷绝缘子瓷裙、基座及法兰是否有裂纹。(2)检查高压支柱瓷绝缘子结合处涂抹的防水胶是否有脱落现象,水泥胶装面是否完好。(3)检查高压支柱瓷绝缘子各连接部位是否有松动现象,金具和螺栓是否锈蚀。(4)检查高压支柱瓷绝缘子是否倾斜及各连接部位是否受力。(5)超声波探伤检测。(二)投运前设备验收的条件(1)支柱瓷绝缘子及组部件工作已结束,人员已退场,场地已清理干净。(2)各项调试、试验合格。(3)施工单位自检合格,缺陷已消除。(4)超声波检测且检测结果合格。(三)投运前设备验收的要求(1)项目负责单位应在工作票结束前通知变电运行人员进行验收。并组织相关单位配合。(2)运行单位应组织精干人员进行验收。在验收中检查发现缺陷,应要求相关单位立即处理。验收合格后方可投入生产运行。、检查项目维护及要求第九条例行巡视、检查项目及要求㈠例行巡视检查(1)日常巡视检查内容项目及要求:1)瓷裙表面污秽程度无放电现象。2)瓷裙、法兰无裂纹、破损现象。3)高压瓷柱绝缘支柱无受力(引线),支柱无倾斜,底座螺栓紧固。4)设备法兰及铁件等部位无裂纹、裂缝现象。(2)对各种值班方式下的巡视时间、次数、内容,各单位应做出明确规定。(3)例行检查巡视分为正常巡视、全面巡视、熄灯巡视。(4)正常巡视:1)有人值班变电所的支柱绝缘子设备,每天至少一次;每周至少进行一次夜间巡视;2)无人值班变电站内的支柱瓷绝缘子设备每周二次巡视检查。(5)全面巡视内容主要是对设备进行全面的外部检查。(6)每周应进行熄灯巡视一次,内容是检查设备有无电晕、放电、接头有无过热现象。㈡检查的要求(1)检查项目及内容:1)检查高压支柱瓷绝缘子瓷裙、基座及法兰是否有裂纹。2)检查高压支柱瓷绝缘子结合处涂抹的防水胶是否有脱落现象,水泥胶装面是否完好。3)检查高压支柱瓷绝缘子各连接部位是否有松动现象,金具和螺栓是否锈蚀。4)检查支柱的引线及接线端子连接处是否有不正常的变色和熔点。5)检查高压支柱瓷绝缘子是否倾斜。6)高压支柱瓷绝缘子的每次停电检查工作都应有相应的记录。㈢维护(1)停电期间必须对支柱瓷绝缘子进行清扫及按周期进行超声波探伤检测,检测中发现有缺陷的支柱瓷绝缘子必须进行立即更换。(2)为了提高支柱瓷绝缘子的耐污水平,根据设备运行情况,可在污秽较严重地区运行的支柱瓷绝缘子可采用表面涂刷RTV涂料等技术措施。(3)检查中发现缺陷时应在设备异常与缺陷记录中详细记录,同时向上级汇报。第十条特殊巡视(一)特殊巡视的条件:当出现下列情况时,需对高压支柱瓷绝缘子进行特殊巡视;(1)大风、雾天、冰雪、冰雹及雷雨后的巡视。(2)设备变动后的巡视。(3)设备新投入运行后的巡视。(4)设备经过检修、改造或长期停运后重新投入运行后的巡视。(5)运行十年及以上高压支柱瓷绝缘子。(二)特殊巡视的要求:(1)雨天及雨后的特殊巡视主要应观查高压支柱瓷绝缘子是否存在放电现象。(2)大风及沙尘天气的特殊巡视主要应观查引线与支柱瓷绝缘子间的连接是否良好,高压支柱瓷绝缘子是否倾斜,相与相之间安全距离是否满足规程要求。(3)设备经过检修、改造或长期停运后重新投入运行,主要应观察支柱瓷绝缘子有无放电及各引线连接处是否有发热现象。(4)特殊巡视的结果应进行记录,对于在巡视中发现的异常情况应记入设备的异常与缺陷记录中。(5)特殊巡视中出现紧急状况时应立即向上级汇报并按照缺陷处理原则进行处理。第十一条缺陷管理及异常处理(1)支柱瓷绝缘子的缺陷分:危急和严重两种1)危急缺陷:支柱瓷绝缘子有裂纹的必须立即更换。2)严重缺陷:支柱瓷绝缘子瓷裙表面有破损(单个面积不得超过40mm²)。应尽快安排修复或更换。第十二条专业管理(1)高压支柱瓷绝缘子的清扫工作按逢停必扫的原则进行。(2)高压支柱瓷绝缘子的检测自投运之日起,三年为一个检测周期,三个周期后,缩短为一年,检测率为100%。(3)高压支柱瓷绝缘子在检测中发现异常情况时,应立即进行更换。(4)各运行单位做好高压支柱瓷绝缘子的年度统计、分析和总结工作,积极开展技术培训,提高高压支柱瓷绝缘子的监督和管理水平。(5)检修、运行部门对所管辖高压支柱瓷绝缘子的运行、检测情况,设备完好率及可靠性指标等情况进行一次全面、简要分析。http
本文标题:电子发烧友网用户转至网络
链接地址:https://www.777doc.com/doc-74663 .html