序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注1一号楼住宅1058.00.400.85423.20262.28497.88共167户二栋楼住宅1020.00.400.85408.00252.86480.00共161户2078.00.400.85831.2515.13977.882078.00.360.84748.08489.37893.933002078.00.360.97748.08189.37771.68100077%序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注1三号楼住宅1058.00.400.85423.20262.28497.88共167户四号楼住宅1020.00.400.85408.00252.86480.00共161户2078.00.400.85831.2515.13977.882078.00.360.84748.08489.37893.933002078.00.360.97748.08189.37771.68100077%序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注排烟风机一12/17KW24.01.000.824.0018.0030.00排烟风机二15/20KW10.01.000.810.007.5012.50消防电梯21x8KW168.00.560.694.08125.44156.80应急照明一103.00.300.8530.9019.1536.35普通照明一30.00.800.8524.0014.8728.24变电站及柴油发电机房负荷15.00.800.8512.007.4414.12弱电机房20.00.800.8516.009.9218.82消控、监控设备20.00.800.8516.009.9218.82景观电力20.00.700.8514.008.6816.47生活水泵52.00.800.841.6031.2052.00462.00.610.75282.6252.11378.70462.00.550.73254.32239.50349.34120462.00.550.91254.32119.50281.00400ΔK∑p=0.9;ΔK∑q=0.95小计变压器装设容量无功补偿容量变压器装设容量补偿后合计无功补偿容量ΔK∑p=0.9;ΔK∑q=0.95小计补偿后合计变压器装设容量变压器负荷率ΔK∑p=0.9;ΔK∑q=0.95无功补偿容量计算功率3T(正常时)用电负荷计算计算功率1T变压器负荷率计算功率2T补偿后合计小计70%序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注排烟风机一12/17KW12.01.000.812.009.0015.00排烟风机二15/20KW15.01.000.815.0011.2518.75消防电梯21x8KW168.00.560.694.08125.44156.80应急照明一54.00.300.8516.2010.0419.06应急照明二8.00.900.857.204.468.47变电站及柴油发电机房负荷10.00.800.858.004.969.41弱电机房20.00.800.8516.009.9218.82消控、监控设备40.00.800.8532.0019.8337.65生活水泵51.01.000.851.0038.2563.75378.00.670.73251.5233.15342.93序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注排烟风机一12/17KW34.01.000.834.0025.5042.50排烟风机四15/20KW7.41.000.87.405.559.25屋顶加压风机一25KW40.01.000.840.0030.0050.00屋顶加压风机二25KW40.01.000.840.0030.0050.00消防电梯21x8KW168.00.500.684.00112.00140.00应急照明一103.00.300.8530.9019.1536.35变电站及柴油发电机房负荷15.01.000.8515.009.3017.65消控、监控设备20.00.800.8516.009.9218.82消防泵、喷淋泵85.01.000.885.0063.75106.25512.40.690.76352.3305.16466.09400500.0093%变压器负荷率柴油机负荷率计算功率1G(停电时,柴油机需保障的负荷)柴油机装设容量1G(停电,且一处火灾时)计算功率小计小计序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注应急照明一55.00.500.8527.5017.0432.35应急照明二53.00.500.8526.5016.4231.18变电站及柴油发电机房负荷10.00.800.858.004.969.41高压配电房负荷10.00.800.858.004.969.41景观电力30.00.400.812.009.0015.00弱电机房20.00.800.8516.009.9218.82消控、监控设备20.00.800.8516.009.9218.82198.00.580.84114.072.21134.95序装设需要功率备用电设备名称功率系数因数有功功率无功功率视在功率号(kW)(Kx)(cosφ)(kW)(kVar)(kVA)注地下室消防动力28.6KW44.00.700.830.8023.1038.50地下室消防动力54.5KW12.00.800.89.607.2012.00消防泵、喷淋泵82KW82.00.500.841.0030.7551.25屋顶加压风机134KW108.00.500.854.0040.5067.50消防电梯45x4180.00.560.6100.80134.40168.00426.00.550.71236.2235.95333.863AA10(停电,且一处火灾时)小计计算功率3AA1(停电时)小计计算功率
本文标题:负荷计算书样本
链接地址:https://www.777doc.com/doc-7697755 .html