您好,欢迎访问三七文档
ICS29.180K41备案号:63143-2018中华人民共和国电力行业标准DL/T2008—2019电力变压器、封闭式组合电器、电力电缆复合式连接现场试验方法Thefieldtestingprocedureforcomplexcombinationofpowertransformer,GISandpowercable2019-06-04发布2019-10-01实施国家能源局发布DL/T2008—2019I目次前言·····································································································································II1范围·········································································································································12规范性引用文件·····················································································································13术语和定义·····························································································································14总则·········································································································································25试验项目·································································································································26试验方法和要求·····················································································································37试验判据·································································································································58试验报告·································································································································6附录A(资料性附录)变压器复合连接侧绝缘特性测量时试验接线·························7附录B(资料性附录)变压器、组合电器、电缆复合连接试验报告示例·················9附录C(资料性附录)变压器、组合电器、电缆复合连接交流耐压试验·················11DL/T2008—2019II前言本标准按照GB/T1.1-2009《标准化工作导则第1部分:标准的结构和编写》的规则编写。本标准由中国电力企业联合会提出。本标准由电力行业电力变压器标准化技术委员会(DL/TC02)归口。本标准起草单位:国网辽宁省电力有限公司电力科学研究院、国网辽宁省电力有限公司、中国电力科学研究院有限公司、国网重庆市电力公司、国网甘肃省电力公司电力科学研究院、国网重庆市电力公司电力科学研究院、国网河北省电力有限公司电力科学研究院、国网吉林省电力有限公司电力科学研究院、国网河南省电力公司、南方电网科学研究院有限责任公司、广州供电局电力试验研究院、西安西电变压器有限责任公司、大唐山东电力检修运营有限公司。本标准主要起草人:于在明、韩洪刚、鲁旭臣、毕海涛、周志强、张淑珍、冯宇、印华、范迪铭、龙英凯、陈志勇、李勐、王南、李学斌、张健壮、彭在兴、黄炎光、郝毅、刘永杰。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市宣武区白广路二条1号,100761)。DL/T2008—20191电力变压器、封闭式组合电器、电力电缆复合式连接现场试验方法1范围本标准规定了电力变压器、封闭式组合电器、电力电缆(以下分别简称:变压器、组合电器、电缆)复合式连接现场试验的术语和定义、试验项目、试验方法和要求、试验报告编写等。本标准适用于35kV~750kV电压等级的变压器、组合电器、电缆复合式连接后的现场试验。2规范性引用文件下列文件对于本标准的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本标准。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本标准。GB/T2900.10-2013电工术语电缆GB/T2900.20-1994电工术语高压开关设备GB/T2900.95-2015电工术语变压器、调压器和电抗器GB/T5832.1气体中微量水分的测定第1部分:电解法GB/T5832.2气体中微量水分的测定第2部分:露点法GB/T8905六氟化硫电气设备中气体管理和检测导则GB50150电气装置安装工程电气设备交接试验标准DL/T474.4现场绝缘试验实施导则交流耐压试验DL/T506六氟化硫电气设备中绝缘气体湿度测量方法DL/T911电力变压器绕组变形的频率响应分析法DL/T1205六氟化硫电气设备分解产物试验方法DL/T1093电力变压器绕组变形的电抗法检测判断导则DL/T5293电气装置安装工程电气设备交接试验报告统一格式JB/T501电力变压器试验导则3术语和定义GB/T2900.20、GB/T2900.95、GB/T2900.10中确立的以及下列术语和定义适用于本标准。DL/T2008—201923.1变压器powertransformer转移电能而不改变其交流电源频率的静止的电能转换器。[GB/T2900.95-2015,术语和定义3.1.1]3.2组合电器gasinsulatedmetal-enclosedswitchgear(GIS)至少有一部分采用高于大气压的气体作为绝缘介质的金属封闭开关设备。[GB/T2900.20-1994,术语和定义3.12]3.3电缆insulatedcable由下列部件构成的组件:——一根或多根绝缘线芯;——各自的包覆层(如有的话);——缆芯保护层(如有的话);——外保护层(如有的话);电缆内可以有附加的无绝缘导体;[GB/T2900.10-2013,术语和定义2.2.1]3.4变压器、组合电器、电缆复合式连接complexcombinationoftransformer,GISandcable(CC-TGC)变压器、组合电器、电缆采用油气套管、气气套管、油油套管、插拔式电缆终端等方式实现变压器与组合电器连接、组合电器与电缆连接、变压器与电缆连接的组合形式。4总则4.1本标准规定了CC-TGC交接、运行后应开展的试验项目、试验方法,实现了对CC-TGC复合连接部位安装质量的考核以及对CC-TGC投运后是否符合运行条件的考核。4.2交接试验时,初值为出厂试验数据;投入运行后例行试验或预防性试验时,初值为CC-TGC连接后交接试验数据。5试验项目5.1投入运行前在变压器、组合电器、电缆复合式连接后投入运行前,应进行的现场交接试验项目如下:DL/T2008—20193a)组合电器与变压器、电缆复合连接部位气室密封性试验;b)组合电器与变压器、电缆复合连接部位气室SF6气体的含水量测量;c)组合电器与变压器、电缆复合连接部位气室分解物测量;d)变压器复合连接侧绕组连同套管的直流电阻测量;e)变压器复合连接侧绕组连同套管的绝缘电阻、吸收比或极化指数测量;f)变压器复合连接侧绕组连同套管的介质损耗因数tanδ测量;g)变压器、组合电器连接部位交流耐压试验;h)组合电器、电缆连接部位交流耐压试验;i)变压器、电缆连接部位交流耐压试验;j)变压器复合连接侧绕组变形试验。5.2投入运行后变压器、组合电器、电缆复合式连接投入运行后,现场例行试验项目包括:a)组合电器与变压器、电缆复合连接部位气室密封性试验;b)组合电器与变压器、电缆复合连接部位气室SF6气体的含水量测量;c)组合电器与变压器、电缆复合连接部位气室分解物测量;d)变压器复合连接侧绕组连同套管的直流电阻测量;e)变压器复合连接侧绕组连同套管的绝缘电阻、吸收比或极化指数测量;f)变压器复合连接侧绕组连同套管的介质损耗因数tanδ测量;6试验方法和要求6.1试验方法6.1.1组合电器与变压器、电缆复合连接部位的气室密封性试验方法试验方法应符合GB50150的规定。6.1.2组合电器与变压器、电缆复合连接部位气室SF6气体的含水量测量试验方法试验方法应符合GB/T5832和DL/T506的规定。6.1.3组合电器与变压器、电缆复合连接部位气室分解物测量试验方法试验方法应符合DL/T1205的规定。6.1.4变压器复合连接侧绕组连同套管的直流电阻测量试验方法试验方法应符合JB/T501的规定。6.1.5变压器复合连接侧绕组连同套管的绝缘电阻、吸收比或极化指数测量试验方法试验方法应符合JB/T501的规定。DL/T2008—201946.1.6变压器复合连接侧绕组连同套管的介质损耗因数tanδ测量试验方法试验方法应符合JB/T501的规定。6.1.7变压器、组合电器连接部位交流耐压试验试验方法试验方法应符合JB/T501的规定。6.1.8组合电器、电缆连接部位交流耐压试验方法试验方法应符合DL/T474.4的规定。6.1.9变压器、电缆连接部位交流耐压试验方法试验方法应符合JB/T501的规定。6.1.10变压器复合连接侧绕组变形试验方法试验方法应符合DL/T911、DL/T1093的规定。6.2试验要求6.2.1组合电器与变压器、电缆复合连接部位的气室密封性试验要求a)采用灵敏度不低于1×10-6(体积比)的检漏仪对复合连接后的密封部位、管道接头等处进行检测;b)必要时可采用局部包扎法进行气体泄漏测量;c)泄漏值的测量应在气室充气24h后进行。6.2.2组合电器与变压器、电缆复合连接部位气室SF6气体的含水量测量试验要求SF6气体含水量的测定应在复合连接处气室充气24h后进行。6.2.3组合电器与变压器、电缆复合连接部位气室SF6气体分解产物测量试验要求试验要求应符合DL/T1205的规定。6.2.4变压器复合连接侧绕组连同套管的直流电阻测量试验要求a)测量应在各分接头的所有位置上进行;b)宜在组合电器与变压器邻近的接地刀闸处测量;例行试验时的测试位置、试验接线应与交接试验时保持一致;6.2.5变压器复合连接侧绕组连同套管的绝缘电阻、吸收比或极化指数测量试验要求a)宜在变压器中性点套管处、或者在组合电器与变压器邻近的接地刀闸处测量。在组合电器与变压器邻近的接地刀闸处测量时,试验接线见附录A.1;在变压器中性点套管处测量时,试验接线见附录A.2;各次试验的试验接线应保持一致。6.2.6变压器复合连接侧绕组连同套管的介质损耗因数tanδ测量试验要求a)宜在组合电器与变压器邻近的接地刀闸处、或者在变压器中性点套管处测量。在组DL/T2008—20195合电器与变压器邻近的接地刀闸处测量时,试验接线见附录
本文标题:DL∕T 2008-2019 电力变压器、封闭式组合电器、电力电缆复合式连接现场试验方法
链接地址:https://www.777doc.com/doc-9472851 .html