您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > DL∕T 2011-2019 大型发电机定子绕组现场更换处理试验规程
ICS29.160.20K21备案号:63143-2018中华人民共和国电力行业标准DL/T2011—2019大型发电机定子绕组现场更换处理试验规程Testcodeforfieldreplacementoflargegeneratorstatorwindings2019-06-04发布2019-10-01实施国家能源局发布DL/T2011—2019I目次前言···························································································································································II1范围·························································································································································32规范性引用文件·····································································································································33术语和定义·············································································································································34一般性要求·············································································································································45试验项目及技术要求·····························································································································4附录A(资料性附录)发电机定子线棒表面电阻测量·····································································11附录B(资料性附录)发电机定子线棒交流耐压试验·····································································12附录C(资料性附录)发电机定子绕组槽电位测量或接触电阻测量··············································13附录D(资料性附录)发电机定子线棒槽楔松紧度检查·································································14DL/T2011—2019II前言本标准按照GB/T1.1-2009《标准化工作导则第1部分:标准的结构和编写》给出的规则起草。本标准由中国电力企业联合会提出。本标准由电力行业电机标准化技术委员会(DL/TC09)归口。本标准起草单位:广东电科院能源技术有限责任公司,上海电气电站设备有限公司上海发电机厂,东方电气集团东方电机有限公司,哈尔滨电机厂有限责任公司,国网河北省电力有限公司电力科学研究院,华电电力科学研究院有限公司东北分公司,国网山东省电力公司电力科学研究院,国网湖北省电力有限公司电力科学研究院,国网湖南省电力有限公司电力科学研究院,广东大唐国际潮州发电有限责任公司,国电科学技术研究院有限公司成都分公司,国网上海市电力公司电力科学研究院。本标准主要起草人:张征平,舒武庆,余平,龚彬,张建忠,王健军,曹志伟,冉旺,崔一铂,徐波,廖方华,江建明,李福兴。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。DL/T2011—20191大型发电机定子绕组现场更换处理试验规程1范围本标准规定了大型发电机定子绕组现场更换处理过程中应进行的试验项目及技术要求。本标准适用于容量等级为50MW及以上的三相隐极同步发电机,其他类型的发电机以及同步调相机可参照此标准执行。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文件。凡是不注日期的引用文件,其昀新版本(包括所有的修改单)适用于本文件。GB/T755旋转电机定额和性能GB/T1029三相同步电机试验方法GB/T2900.1电工术语基本术语GB/T2900.25电工术语旋转电机GB/T16927.1高电压试验技术第1部分:一般定义及试验要求GB/T20140隐极同步发电机定子绕组端部动态特性和振动测量方法及评定GB/T20160旋转电机绝缘电阻测试GB/T20833.1旋转电机定子绕组绝缘第1部分:离线局部放电测量GB/T20835发电机定子铁心磁化试验导则GB/T21205旋转电机整修规范GB26860电力安全工作规程发电厂和变电站电气部分GB50150电气装置安装工程电气设备交接试验标准DL/T298发电机定子绕组端部电晕检测与评定导则DL/T492发电机环氧云母定子绕组绝缘老化鉴定导则DL/T596电力设备预防性试验规程DL/T801大型发电机内冷却水质及系统技术要求DL/T1522发电机定子绕组内冷水系统水流量超声波测量方法及评定导则DL/T1524发电机红外检测方法及评定导则DL/T1768旋转电机预防性试验规程JB/T6204高压交流电机定子线圈及绕组绝缘耐电压试验规范JB/T6228汽轮发电机绕组内部水系统检验方法及评定JB/T7608测量高压交流电机线圈介质损耗角正切试验方法及限值3术语和定义GB/T2900.1和GB/T2900.25界定的以及下列术语和定义适用于本文件。3.1定子嵌线statorbarembedding将定子线棒嵌入发电机定子槽内并固定的过程。DL/T2011—201923.2新线棒newstatorbar出厂后没有嵌线使用过的定子线棒,包括没有使用过且保存良好的备品线棒。3.3复用线棒reusedstatorbar从发电机定子槽内拆出并经处理后可重新使用的定子线棒。3.4剩余线棒remainderstatorbar发电机定子槽内未拆出的线棒。3.5全部更换fullreplacement发电机定子槽内所有线棒全部拆出并更换为新线棒的处理方式。3.6局部更换partialreplacement除全部更换以外的处理方式。3.7定子线棒铁心段statorcorecorrespondingpartofstatorbar定子线棒对应定子铁心长度的部分。3.8定子线棒端部endingofstatorbar定子绕组中伸出定子铁心两端之外的部分。3.9总烘overallheating定子绕组总体装配后所进行的烘焙工序。4一般性要求4.1绝缘试验时,周围环境温度不宜低于5℃,空气相对湿度不宜高于80%。试验时应同时测量并记录被试品的温度、周围环境空气的温度和相对湿度。4.2对单根定子线棒进行高压试验时,应在线棒表面包覆铝箔、锡箔等金属材料作为电极,并尽量减少电极与线棒表面的气隙。4.3单根定子新线棒采用抽样方式进行试验时,对于隐极发电机,抽样数量不得少于每台(或每批)定子线棒总数的10%。抽样测量结果不合格时,应加倍进行抽样试验。若加倍抽样试验后仍不合格,则应对全部的定子线棒进行试验检查。5试验项目及技术要求DL/T2011—201935.1定子绕组现场更换处理过程中,应根据发电机的不同冷却方式,分阶段进行相应的试验。5.2水内冷型发电机现场全部更换处理定子绕组试验项目如表1所示。表1水内冷型发电机定子绕组现场全部更换处理试验项目试验阶段试验对象试验项目试验要求拆出线棒后定子铁心定子铁心磁化试验参照GB/T20835。表面电阻测量必要时。抽样进行试验。试验要求见附录A。耐电压试验前、后,绝缘电阻测量参照GB/T20160。介质损耗因数测量必要时。抽样进行试验。试验要求见JB/T7608。局部放电量测量必要时,抽样进行试验。试验要求见GB/T20833.1。端部电晕检测必要时,抽样进行试验。试验要求见DL/T298。端部工频交流耐压试验必要时,见附录B。铁心段工频交流耐压试验见附录B。水压试验或气压试验参照JB/T6228。单根新线棒水流量试验或气流量试验参照JB/T6228。新线棒嵌线前层间测温元件测温元件直流电阻和绝缘电阻检测参照DL/T1768。耐电压试验前、后,绝缘电阻测量参照GB/T20160。端部电晕检测参照DL/T298。工频交流耐压试验参照JB/T6204。下层线棒嵌线后下层线棒整体槽电位测量或接触电阻测量见附录C。耐电压试验前、后,绝缘电阻测量参照GB/T20160。端部电晕检测必要时。试验要求见DL/T298。工频交流耐压试验参照JB/T6204。上下层线棒整体槽电位测量或接触电阻测量见附录C。上层线棒嵌线后层间测温元件测温元件直流电阻和绝缘电阻检测参照DL/T1768。打完槽楔后槽楔槽楔松紧度检查见附录D。单根线棒水流量试验或气流量试验参照JB/T6228。环形引线对环形引线内部进行吹扫无异物、无堵塞。上、下层接头连接前或安装绝缘引水管之前汇水管绝缘电阻测量按制造厂技术要求执行。焊接头质量检测参照JB/T8991和DL/T1524。上、下层接头连接后定子绕组定子绕组直流电阻测量参照GB/T1029。安装绝缘引水管定子绕组水压试验或气压试验参照JB/T6228。DL/T2011—20194试验阶段试验对象试验项目试验要求内冷水系统流通性检查参见JB/T6228,采用超声波水流量试验方法的参照DL/T1522。耐电压试验前、后,绝缘电阻测量参照GB/T20160。之后,手包绝缘或安装绝缘盒前工频交流耐压试验参照JB/T6204。定子铁心定子铁心磁化试验参照GB/T20835。定子绕组定子绕组直流电阻测量参照GB/T1029和DL/T1768。定子总烘后层间及出水测温元件测温元件直流电阻和绝缘电阻检测参照DL/T1768。端部手包绝缘施加直流电压测量参照DL/T1612。端部动态特性试验参照GB/T20140。耐电压试验前、后,绝缘电阻测量参照GB/T20160。直流泄漏电流及耐压试验参照DL/T1768。局部放电量测量必要时。试验要求见GB/T20833.1。介质损耗因数测量必要时。试验要求见JB/T7608。端部电晕检测试验参照DL/T298。出线连接完成,通水后,穿转子前定子绕组工频交流耐压试验参照JB/T6204。直流泄漏电流及耐压试验参照DL/T1768。空载试验参照GB/T1029和DL/T1768。三相稳态短路试验参照GB/T1029和DL/T1768。穿转子、定子端盖安装后,机组启动期间发电机有其它特殊要求的试验参照相关试验规程。5.3表面冷却型发电机现场全部更换处理定子绕组试验项目如表2所示。表2表面冷却型发电机定子绕组现场全部更换处理试验项目试验阶段试验对象试验项目参照标准拆出线棒后定子铁心定子铁心磁化试验参照GB/T20835。表面电阻测量必要时。抽样进行试验,试验要求见附录A。耐电压试验前、后,绝缘电阻测量参照GB/T20160。介质损耗因数测量必要时。抽样进行试验,试验要求见JB/T7608。新线棒嵌线前单根新线棒局部放电量测量必要时,抽样进行试验,试验要求见GB/T20833.1。DL/T201
本文标题:DL∕T 2011-2019 大型发电机定子绕组现场更换处理试验规程
链接地址:https://www.777doc.com/doc-9494165 .html