您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 国内外标准规范 > 15.35kV复合绝缘子技术规范(专用部分)(1)
招标编号:-------河南省电力公司集中规模招标采购设备材料招标文件范本35kV交流架空线路用复合绝缘子招标文件(技术规范专用部分)项目单位:年月目录表1货物需求及供货范围一览表···························································1表2专用工具和备品供货表(投标人填写)·············································11工程概况·······················································································11.1项目名称:··················································································11.2项目单位:··················································································11.3设计单位:··················································································11.4工程规模:··················································································12适用范围·······················································································13使用条件·······················································································14技术参数和性能要求········································································14.1技术参数表··················································································15技术偏差·······················································································26其它要求·······················································································36.1第三方抽样试验·············································································36.2采用防鸟害措施············································································37特殊说明·······················································································3附录A技术规范通用部分条款变更表·····················································4分标编号:09表1货物需求及供货范围一览表序号项目名称材料名称单位项目单位要求投标人响应备注型号和规格数量型号和规格数量12345表2专用工具和备品供货表(投标人填写)序号名称型号及规格数量生产厂家123注:应随合同所订的绝缘子一起供给每种绝缘子供货数量的5%锁紧销作为备品,以上专用工具和备品计入投标总价。·1·1、工程概况1.1项目名称:1.2项目单位:1.3设计单位:1.4工程规模:线路长度、起讫点、主要塔型、导线规格和分裂数、沿线污区分布状况、绝缘子用量以及地形地貌。2、适用范围本规范书适用于工程kV输电线路工程的复合绝缘子(以下简称绝缘子)的设计、制造、试验、包装和供货等技术要求。3、使用条件绝缘子使用环境条件如表3。表3绝缘子使用环境条件序号项目内容/参数1安装地点2海拔高度(m)3最低环境温度(℃)4最高环境温度(℃)5覆冰厚度(mm)6最大风速(m/s)7年平均雷电日8污秽等级4、技术参数和性能要求技术参数响应表中某些项目参数由招标人提出,如果招标人不提出要求,则由投标人提供。投标人应认真逐项填写技术参数响应表中投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。如有偏差,请填写技术偏差表。表中带“*”项为关键参数,投标资料不详实、严重漏项或不满足带“*”项将视为实质性不响应。技术参数表表4交流kV复合绝缘子技术参数响应表投标人名称:项目招标人要求值投标人保证值·2·制造商(厂)名称绝缘子型号额定电压(kV)*公称结构高度(mm)*绝缘距离(mm)*均压装置间距离(mm)公称爬电距离(mm)*连接标记*芯棒直径(mm)规定机械破坏负荷(kN)*逐个拉伸试验负荷(kN)湿工频1min耐受电压(kV)雷电全波冲击耐受电压(kV)可见电晕电压(kV)伞形结构均压装置材料均压装置外径/管径(mm)均压环屏蔽深度(mm)防鸟害型均压装置(是/否)每支重量(含均压装置)(kg)投标人授权代表签字:5、技术偏差投标人提供的产品技术规范应与本招标文件中规定的要求一致。若有偏差投标人应如实、认真地填写偏差值;若无技术偏差则视为完全满足本技术规范的要求,且在技术偏差表中填写“无偏差”。表5技术偏差表投标人名称:序号项目对应条款编号招标文件要求偏差备注1234·3·投标人授权代表签字:6、其它要求6.1第三方抽样试验由买方决定是否需要第三方抽样试验。6.2采用防鸟害措施由买方提出是否采用其它防鸟害措施。7、特殊说明(1)技术规范通用部分条款变更表是对技术规范通用部分的补充和修改,对本规范的理解以变更后的表述为准;(2)当专用部分与通用部分发生冲突时,以专用部分为准。·4·附录A技术规范通用部分条款变更表(本表是对技术规范“通用部分”的补充和修改,如有冲突,应以本表为准)变更条款页码、序号原表述变更后表述
本文标题:15.35kV复合绝缘子技术规范(专用部分)(1)
链接地址:https://www.777doc.com/doc-1289678 .html