您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 给排水/暖通与智能化 > 空调计算040408
工程名稱:logitech建築名稱:fab11.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)3428.226.665.122.11.13491外氣條件(冬)-4-5.2-7.37520.7650.6供風條件14.513.512.9909.31.2238.1室內要求條件241712.9509.31.18147.92.室狀態diningroomshopfloorprivatecabinetpreformingareaproductionline/J1stock小计潔淨等級樓板面積(m2)142083813686127009753.0高度(m)4.24.24.24.2外牆面積(m2)000000.03.外氣處理正壓換氣(次/hr)000機台排氣(cmm)0351.961407外氣需求(cmm)340387.15623.2561547.7002298.1顯熱(kw)98.32111.966.73447.560.000.00潛熱(kw)159.91182.0810.94727.900.000.00冷卻量(kw)258.23294.0417.661175.460.000.00冷卻量(USRT)73.4283.615.02334.230.000.00OverCool(kw)49.4156.273.38224.930.000.004.循環風量潔淨循環(次/hr)循環風量(cmm)05.室內發熱(1)熱貫流率(w/m2℃)1.891.891.891.891.891.89外牆傳導(kw)0.000.000.000.000.000.00(2)照明電力(w/m2)151515151515照明負荷(kw)21.312.5720.5291.90500146.3(3)工作人員(人)60050041.0445000發熱量(w/人)显606060606060發熱量(w/人)潜175175175175175175人員負荷(kw)显36.0030.002.4627.000.000.00人員負荷(kw)潜105.0087.507.1878.750.000.00278.4人員負荷(kw)总141.00117.509.64105.750.000.00373.9(4)設備(kw)0068.4612.700681.1(5)FCU(台數)FCU負荷(kw)3.75總和(kw)614391732003022114523622004587.26.循環冷卻0.0冷卻量(kw)269.86280.34105.671682.140.000.002338.0冷卻量(USRT)76.7379.7130.04478.300.000.00進風溫度(℃)303030303030出風溫度(℃)冰水溫差(℃)666655冰水流量(lpm)644.67669.71252.424018.440.000.007.冰水機總冷卻量(kw)374.86367.84112.851760.890.000.002616.4總冷卻量(USRT)106.59104.5932.09500.690.000.00冰水溫差(℃)666666冰水流量(m3/hr)53.7352.7216.17252.390.000.00Header管徑(mm)97.4896.5653.48211.270.000.00制程用冷却水(T/H)3.63.6制程用冷冻水(T/H)2500.23.422503.60.0加热量(KW)325.32386.39-64.95890.300.000.001537.06加湿量(Kg/hr)178.70203.4912.22813.470.000.001207.9加热用蒸汽量加湿用蒸汽量總冷卻量(kw)3434.08水量(lpm)25.94總冷卻量(USRT)976.45水量(m3/hr)1.56冷卻水溫差(℃)5冷卻水量(m3/hr)590.66Header管徑(mm)323.19制冷单位负荷(W/M2)263.99438.9682.49287.40#DIV/0!供热单位负荷(W/M2)229.10461.09-47.48145.31#DIV/0!8.冷卻水塔10.凝結水量2019/11/22/23:57工程名稱:logitech建築名稱:fab21.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)3428.226.665.122.11.13491外氣條件(冬)-4-5.2-7.37520.7650.6供風條件14.513.512.9909.31.2238.1室內要求條件241712.9509.31.18147.92.室狀態shopfloorprivatecabinetlaboratoryIQCproductionline/J1stock小计潔淨等級樓板面積(m2)76518414706127009203.0高度(m)4.24.24.24.200外牆面積(m2)0000000.03.外氣處理正壓換氣(次/hr)00機台排氣(cmm)321.31407外氣需求(cmm)353.4336.827.051547.7001945.0顯熱(kw)102.2010.652.04447.560.000.00潛熱(kw)166.2217.323.32727.900.000.00冷卻量(kw)268.4327.965.351175.460.000.00冷卻量(USRT)76.327.951.52334.230.000.00OverCool(kw)51.365.351.02224.930.000.004.循環風量潔淨循環(次/hr)循環風量(cmm)05.室內發熱(1)熱貫流率(w/m2℃)1.891.891.891.891.891.89外牆傳導(kw)0.000.000.000.000.000.00(2)照明電力(w/m2)151515152020照明負荷(kw)11.47527.6157.0591.90500138.0(3)工作人員(人)50073.6414.145000發熱量(w/人)显606060606060發熱量(w/人)潜175175175175175175人員負荷(kw)显30.004.420.8527.000.000.00人員負荷(kw)潜87.5012.892.4778.750.000.00181.6人員負荷(kw)总117.5017.313.31105.750.000.00243.9(4)設備(kw)092.050612.700704.8(5)FCU(台數)FCU負荷(kw)0總和(kw)41124873200205614393622004480.56.循環冷卻0.0冷卻量(kw)258.54146.7012.231682.140.000.002099.6冷卻量(USRT)73.5141.713.48478.300.000.00進風溫度(℃)303030303030出風溫度(℃)冰水溫差(℃)666666冰水流量(lpm)617.62350.4429.214018.440.000.007.冰水機總冷卻量(kw)346.04159.5814.691760.890.000.002281.2總冷卻量(USRT)98.3945.384.18500.690.000.00648.6冰水溫差(℃)666666冰水流量(m3/hr)49.6022.872.11252.390.000.00Header管徑(mm)93.6563.6019.30211.270.000.00制程用冷却水(T/H)3.63.6制程用冷冻水(T/H)2500.23.422503.60.0加热量(KW)352.74-81.72-7.14890.300.000.001154.2加湿量(Kg/hr)185.7619.353.71813.470.000.001022.3加热用蒸汽量加湿用蒸汽量總冷卻量(kw)2994.08水量(lpm)21.95總冷卻量(USRT)851.34水量(m3/hr)1.32冷卻水溫差(℃)5冷卻水量(m3/hr)514.98Header管徑(mm)301.78制冷单位负荷(W/M2)452.3486.6831.26287.40#DIV/0!供热单位负荷(W/M2)461.09-44.39-15.20145.31#DIV/0!8.冷卻水塔10.凝結水量2019/11/22/23:57工程名稱:logitech建築名稱:office1.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)3428.226.665.122.11.13491外氣條件(冬)-4-5.2-7.37520.7650.6外氣供風條件14.513.512.9909.31.2238.1室內要求條件241712.9509.31.18147.9冬天室內條件2215.411.1508.20.8443.12.室狀態MSstock1FLoffice2FLoffice小计潔淨等級樓板面積(m2)70045043205470高度(m)4.24.24.2外牆面積(m2)00003.外氣處理正壓換氣(次/hr)機台排氣(cmm)外氣需求(cmm)11.9025.50293.5333333330.9333319.0顯熱(kw)3.447.3784.88潛熱(kw)5.6011.99138.05冷卻量(kw)9.0419.37222.93冷卻量(USRT)2.575.5163.3971.466268.9OverCool(kw)1.733.7142.664.循環風量潔淨循環(次/hr)循環風量(cmm)5.室內發熱(1)熱貫流率(w/m2℃)3.23.23.2外牆傳導(kw)0.00.00.0(2)照明電力(w/m2)152020照明負荷(kw)10.50986.4105.900(3)工作人員(人)21.0045518發熱量(w/人)显616166發熱量(w/人)潜7373105人員負荷(kw)显1.282.7534.1938.21人員負荷(kw)潜1.533.2954.3959.21人員負荷(kw)总2.816.0388.5897.42(4)設備(kw)17.0917.09(5)FCU(台數)01280FCU負荷(kw)02.416總和(kw)12141546.循環冷卻冷卻量(kw)19.0929.81333.96382.85冷卻量(USRT)5.438.4894.96進風溫度(℃)303030出風溫度(℃)冰水溫差(℃)666冰水流量(lpm)45.6071.20797.7919.85.87.冰水機21.975總冷卻量(kw)20.6233.09388.35442.06總冷卻量(USRT)5.869.41110.42冰水溫差(℃)666冰水流量(m3/hr)2.964.7455.66Header管徑(mm)22.8628.9699.21制程用冷却水(T/H)0制程用冷冻水(T/H)0加热量(KW)0.5214.61185.390.000.00200.52加湿量(Kg/hr)5.3111.38131.030.000.00147.73總冷卻量(kw)580.21加熱量(kw)(120w/m2)水量(lpm)3.74總冷卻量(USRT)164.98加濕量(kg/hr)水量(m3/hr)0.22冷卻水溫差(℃)5冷卻水量(m3/hr)99.80Header管徑(mm)132.848.冷卻水塔9.冬季加熱加濕10.凝結水量2019/11/22/23:57制冷单位负荷(W/M2)29.4673.5489.90供热单位负荷(W/M2)0.7432.4742.912019/11/22/23:576.25.8772727273.872.5666666672.2909090911.052019/11/22/23:57工程
本文标题:空调计算040408
链接地址:https://www.777doc.com/doc-1838927 .html