您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 电气安装工程 > 瑞姆DF2FR-G5循环式说明书
第1页非常感谢您选用广州瑞姆节能设备有限公司生产的商用循环式空气能热泵热水机组,请您安装使用之前务必详细阅读《安装使用说明书》,并按照本公司《安装使用说明书》技术要求安装和使用。目录(一)注意事项···············································································2(二)使用方法···············································································31.机组特点············································································32.机组结构············································································33.操作说明············································································44.机组运行说明····································································9(三)维护保养··············································································12(四)安装说明··············································································12第2页1.安装注意事项··································································122.安装示意图······································································123.安装外形图······································································134.工程安装布置图······························································14(五)故障排除··············································································15(六)技术参数··············································································16一、注意事项为防止使用者本人或他人的人身财产安全受到损失,正确并安全地使用本机组,请认真阅读本使用说明书中记载的重要内容。请充分理解以下的内容后再安装使用,遵守以下的注意事项,否则本公司不承担由此造成的的机器损坏、财产损失和人身伤害责任。注意一、安全注意事项确认用电设备使用功率主电源要符合设备功率的要求,用电必须符合国家民用/商用使用要求。否则会使机组过压、欠压运行而损坏,甚至发生火灾。确认地线确认是否正确接地。若接地不完善,可能引起人员的触电事第3页故。确认漏电保护开关确认机组和用户电源之间是否安装了功率相等漏电保护开关,接地性能良好。若不安装漏电保护开关,则可能造成人员触电或发生火灾。委托专业人员安装请委托专业人员进行安装。其他人员安装可能造成安装不完善,从而引起漏水、人员触电事故或引发火灾。确认主控制器安装位置安装主控制器时请务必安装在防水的地方,安装一定要牢靠。确认水管及接线的正确性完成机组水管及接线时,须检查无误后再将机组接通电源运行。注意二、使用注意事项断水断电后的应急措施在寒冷地区不使用时,请不要断水断电以免冻坏套管换热器。如遇到停电时,请将套管换热器内的冷水排完,否则会造成冻坏套管换热器,从而使机组不能正常使用。建议工程安装时务必装有冷凝水的排水管,防止在排水时有大量的冷凝水流到地面造成大面积积水现象。检查设备循环水的流量和压力设备在正常使用时,必须保证设备循环水的流量和压力,以免造成机组保护,缺水运行。不能随意移动探测器温度探测器不可脱离水箱温度探测盲管,以免造成机组加热器过热,损坏机组。热水温度要适宜当水温在50℃以上的热水时,必须冷热水混合使用,以免烫伤(尤其是老人和儿童)。机组维护及修理非专业技术人员不得自行修理或调整机组的控制方式,应与当地的服务商联系。保险丝的选用要相匹配禁止没有使用相应的保险丝。若用铜或铁丝,则有可能造成故障或引发火灾。第4页防止机组发生火灾不可将可燃性喷雾剂直接喷向热水机组,否则易引发火灾事故。切断手动电源开关发生异常时(焦臭味),应立即切断手动电源开关,停止运行,并与经销商取得联系。若继续异常运行,则可能造成人员触电及引发火灾。二、使用方法1.机组特点:机组是以空气为热源制取高温热水,其效率最高达300-500%;全自动微电脑控制,无须专人看管;水电隔离,无任何污染排放,具有环保、节能、可靠、方便等;全天候工作,产水量大,可实现集中供水;采用循环加热的方式,系统更可靠,效率更高;2.机组结构整个热水供水系统由水箱,热泵机组两大部分组成,通过管道循环泵使水和机组换热器进行强制换热,促使水箱内的冷水不断的循环加热升温至设定温度后停机。所有的运行检测过程由机体内部的微电脑控制主板控制和操作。3.操作说明开机前的准备:检查电源是否连接牢固,接地电阻和绝缘电阻是否符合要求:检查水箱内的水是否加满:检查管道内的空气是否排空:检查风机内是否有碰撞或有异物掉入:检查水温探测器的温度是否正确:检查所有闸阀和开关是否已经打开:(1)面板图案操作说明:警告!非专业操作人员不得进行程序设置,请在开机之前检查所有条件符合开机要求。第5页41定时时间△△▽查询模式温度▽12设置3234567814第6页序号图标说明1显示电加热自动模式制热符号,符号闪烁时是显示强制启动电加热符号2显示水箱温度3显示模块机组号4显示设置温度5显示水箱液位符号6显示水箱补水符号7显示压缩机工作状态8显示水泵工作状态.9显示风机工作状态10显示定时关机符号11设置定时功能时显示时间和故障符号出现时显示故障代码12显示机组有故障符号13显示定时开机符号14显示正在除霜符号(2)开/关机键□按“开/关机”键,机组开机,指示灯亮;□再按“开/关机”键,机组关闭,指示灯灭。(3)□按“模式”键,选择所需的模式(电加热自动模式或电加热强制模式)电加热自动模式显示制热符号(太阳图标),强制模式制热符号闪烁。(4)□循环定时(〖P2〗设置为1)时,按“查询”键可显示实时时间。按“查询”键,进入参数查询状态,再按“时间”键可查询d1d2d3d4d5d6d7d8d9dAE1E2E3E4E5E6E7E8F1F2的参数,再按“查询”键退出查询状态。双系统时:d1出水温度,d2水箱温度,d3室外空气温度,d4盘管温度1,d5盘管温度2,d6排气管温度1,d7排气管温度2,d8,d9,dA下循环水温度,F1压缩机1模式查询134121185761210123456789第7页电流,F2压缩机2电流,E1--E8待用。单系统时:d1出水温度,d2水箱温度,d3室外空气温度,d4盘管温度1,d6排气管温度1,d5,d7,d8,d9,dA,F1压缩机1电流,F2压缩机2电流,E1--E8待用。(5)定时开关机设定方法:①设置〖P2〗设置为0时是组合定时(设置请参阅下面设置章节)□开机状态下,按“定时”键,定时关机;□关机状态下,按“定时”键,定时开机;□按“定时”键后,小时时间闪显;□按键,调整小时定时时间□再按“定时”键后,分钟时间闪显;□按“时间▽△”键,调整分钟定时时间□再按“定时”键,定时设定完成□再按“定时”键,则取消定时②设置〖P2〗设置为1时是循环定时按“定时”键后,小时时间闪显,开始设定定时开时间;□按“时间▽△”键,调整小时定时开时间□再按“定时”键后,分钟时间闪显;□按“时间▽△”键,调整分钟定时开时间□再按“定时”键,定时开时间设定完毕,设定定时关机时间(同上)。③时钟设定□按住“定时”键5秒钟后,小时时间闪显,进入时钟设定状态;□按“时间▽△”键,调整小时时钟□再按“定时”键后,分钟时间闪显;□按“时间▽△”键,调整分钟时钟□再按“定时”键,时钟设定完成。(6)参数设置①.用户级参数设置(设置温度设置)□按键进入用户级温度设置,显示“P1”及参数,接着按键可设定P1(制热设置温度)的参数。□再按“时间▽△”键,则显示“P2”及参数,接着按“温度▽△”键可设定P2(组合定时/循环定时选择)的参数。□再按“设置”键,则退出用户级参数设置。参数名称单元序出厂设最大值最小值▽△定时时间温度△▽设置第8页号置制热设置温度P155〖b8〗5组合定时/循环定时选择P201:循环定时(每24小时循环运行)0:组合定时(24小时内一次有效)下循环水设置温度P340热水设置温度-〖bE〗5下循环回差温度P4582②.管理级参数设置□按“设置”键达10秒以上,进入管理级参数设置菜单(密码进入)□按“查询”键,可选择[系统功能设置菜单][保护温度时间菜单][除霜参数菜单]或[密码菜单]□按“时间△”或“时间▽”键可选择具体菜单中的设置项,□按“温度△”或“温度▽”键可调整具体的参数,□按“设置”键,存储数据并退出。系统功能设置表1参数名称单元序号出厂设置01O0液位选择(b1)1(0-1)有液位无液位电加热选择(b2)1(0-1)有无下循环水泵选择(b3)1(0-1)有无模块上载停止点(b4)1(0-1)〖P1〗〖P1〗-〖bE〗防冻水流检测(b5)1(0-1)检测不检测锁定保护次数(b6)3(1-7)过流检测延时(b7)5(2-15)秒〖P1〗设置最高点(b8)55(25-80)相位保护选择(b9)1(0-1)保护不保护压缩机数量(bA)根据单双系统决定数量(1-2)模块数量(bb)1(1-8)模块上载时间(bC)1(1-8)分水温温度补偿(bd)0(-10-+10)(防冻时不补偿)压机回差温度(bE)4(2-8)室外高温时设(bF)45(25-80)第9页置温度限制保护温度时间参数表2参数名称单元序号出厂设置最大值最小值制热出水温度过高保护(C1)63℃80℃`40℃低速风室外温度(单风速风机选0)(C2)20℃35℃0℃停风机排气温度(实际温度-100℃)(C3)08℃(108℃)20℃(120℃)`-30℃(70℃)开停风机回差温度(C4)5155停压机排气温度(实际温度-100℃)(C5)10℃(110℃)25℃(125℃)0℃(100℃)压机低温限制温度(无限制选-20℃)(C6)-15℃10℃-20℃停风机室外空气温度(C7)5℃10℃-5℃进入化霜室外盘管温度条件(C8)0℃5℃-5℃压缩机启动保护(C9)3分钟15分钟3分钟压缩机运行满足时间(CA)3分钟10分钟1分钟屏蔽低压压力检测时间(Cb)60分钟60分钟0分钟保护条件持续时间(CC)3秒10秒1秒水流开关持续检测时间(Cd)10秒60秒1秒化霜参数表3参数名称单元序号出厂设置最大值最小值首次进入化霜压缩机工作累计时间(d1)36分钟99分钟5分钟化霜时间(d2)6分钟15分钟2分钟进入化霜室外温差(d3)3℃15℃2℃退出化霜室外盘管温度条件(d4)25℃30℃0℃注:在开机且主模块压机开启制热水状态下,按住“温度下降键▽”达8秒进入强制除霜,〖d7〗为除霜时长。除霜时雪花符号闪显。强制除霜中可按“温度下降键▽”退出除霜。4.机组运行说明开机运行(1)初次上电按开关键一次,指示灯显示绿灯,此时
本文标题:瑞姆DF2FR-G5循环式说明书
链接地址:https://www.777doc.com/doc-2195894 .html