您好,欢迎访问三七文档
1摘要本次设计以35KV站为主要设计对象,分为任务书、计算说明书二部分,同时附有1张电气主接线图加以说明。该变电站设有2台主变压器,站内主接线分为35kV、和10kV两个电压等级。两个电压等级均单母分段的接线方式。本次设计中进行了电气主接线图形式的论证、短路电流计算、主要电气设备选择及校验(包括断路器、隔离开关、电流互感器、电压互感器),同时介绍了防雷保护的配置、继电保护的规划等相关方面的知识。2ABSTRACTThisdesignisthen35kVtransformersubstationsisforprimarilydesigntheobjecting,andisdividedintothemissionbook,calculationbook,manualthreepart,atthesametimefish-eye1electricitythelordconnectthelinediagramtotakeintotheelucidation.Thattransformersubstationestablishestohave2maintransformerofsets,standtheinsidelordtoconnectthelinetoisdividedinto35kV,with10twoelectricvoltagegradesofkVs.Theeachelectricvoltagegradedistinguishestheconnectingofsegmentthelinemethodwithsinglemother.Proceedsinthisdesigntheelectricitylordconnectthelinesketchthetype'sargument,short-circuitelectriccurrentcalculation,mainelectricityequipments(includetobreaktheroad,insulatetheswitch,electriccurrentwitheachother,electricvoltagetowitheachother),andintroducedtodefendwhatthunderprotecttoinstallatthesametime,aftertheprogrammingetc.thattheelectricityprotectthepartiesconcerned'sknowledge.Thispaperisa35KVsubstationdesignbook,includingassignmentpaper,explanationpaper,calculationpaperand1graphs.Thesubstationhave2primarytransformerincluding2voltagedegree:35KVand10KV.Everydegreeadoptedsectionedsinglebusprimaryconnectionmodeltosupplypower.Inthispaper,wehavecomputedshort-circuitcurrent,designedandtestedthePrimaryelectricequipment(circuitbreaker,isolationswitcher,currenttransfer,voltagetransfer,busetc),atthesametime,wealsointroducedprevent-thunderprotection,primaryprotectionandotherknowledgerelevant.3目录ABSTRACT..........................................................21绪论.........................................................41.1原始资料和问题的提出.......................................41.2国内外现状.................................................41.2.1国外无人值班变电站的发展.................................41.2.1国内无人值班变电站的发展.................................51.3本文的设计内容.............................................52无人值班变电站的基础知识......................................62.1无人值班变电站的概念和功能.................................62.1.1无人值班变电站的概念.....................................62.1.1无人值班变电站的功能.....................................63主接线的选择...................................................73.1常用的主接线方案介绍及其优缺点.............................73.2本设计所选择的主接线方案及其选择理由.....................83.3变压器的选型及台数.........................................94短路电流计算..................................................104.1短路计算的目的............................................104.2变压器等值电抗计算........................................104.3短路点的确定..............................................104.435kv母线上三相短路时.....................................114.510KV母线上短路计算.......................................114.6短路电流汇总表............................................125高压电气设备的选型.............................................145.1高压电气设备选择一般规定................................145.1.1高压电气选择的一般原则..................................145.1.2母线的选择.............................................145.1.3高压断路器的选择及隔离开关的选择......................155.1.4互感器的选择............................................176高压配电装置..................................................226.1配电装置简介及其优缺点..................................226.2本设计所选择的配电装置及选择理由........................227二次设备......................................................247.1继电保护的作用........................................247.2变压器的保护..............................................247.210kV母线分段断路器的保护.................................257.2馈线保护..................................................257.3监控系统.................................................259通信系统.......................................................279.1常用通信方式介绍及其优缺点................................2749.2本站所采用通信方式........................................27第10章结论和展望参考文献致谢1绪论1.1原始资料和问题的提出本工程为满足某区域对电力的需求,经系统规划设计,论证新建一座35kV终端变电站。变电站安装两台3150VA变压器。电压分为35kV、10kV两个电压等级。35kV侧二回,一回进线,另一回供另一座远方35kV变电站。10kV最大负荷4500kVA最大一回负荷为1000KVA,最大负荷与最小负荷比为0.65,各侧功率因数COSφ及最大负荷小时数为:35KV侧Tmax=4200小时/年COSφ=0.85。查表损耗小时数T=2800小时10KV侧Tmax=4500小时/年COSφ=0.8。查表损耗小时数T=3150小时35KV侧电源近似为无限大电源系统,以100MVA为基准容量,归算到本所35KV侧母线阻抗为0.2Ω本所环境要求:本所所在地地势平坦,交通便利、空气无污染。该地区最热月平均气温为28℃,年平均气温16℃,绝对最高气温40℃,土壤最热平均月气温18℃,风速为25m/s。微风风速小于5m/s。该所位于生荒土地,便于进出线等诸多方面的考虑。且考虑有视野较宽阔,有足够的间隔。1.2国内外现状1.2.1国外无人值班变电站的发展变电站自动化和无人值班是当今电网调度自动化领域的热门课题,其发展势头正方兴未艾。国外有一种观点认为,人容易受环境、情绪、性格、疾5病等诸多因素影响,因此本身就是一个不可靠因素。确实有不少事故是由人为误操作引起的,从这个角度看,无人值班确实可以提高运行可靠性。变电站自动化是在计算机技术和网络通信技术的基础上发展起来的。国外在八十年代已有分散式变电站自动化系统问世,以西门子(SIEMENS)公司为例,该公司第1套全分散式变电站自动化系统LSA678早在1985年就在德国汉诺威投入运行,至1993年初已有300多套系统在德国及欧洲的各种电压等级的变电站运行。1.2.1国内无人值班变电站的发展我国的变电站自动化工作起步较晚,大约从九十年代开始,初始阶段主要研制和生产集中式的变电站自动化系统,例DISA-1型,BJ-1型,iES-60型,XWJK-1000A型,FD-97等。九十年代中期开始研制分散式变电站自动化系统,如DISA-2型,DISA-3型,BJ-F3,CSC-2000型,DCAP3200型,FDK型等,与国外先进水平相比,大约有十年的差距。许多高校、科研单位、制造厂家以及规划设计、基建和运行部门在学习和借鉴国外先进技术的同时,正结合我国的实际情况共同努力继续开发更加符合我国国情的变电站自动化系统。可以预计,今后其发展和推广的速度会越来越快,与国外的差距会逐步缩小。1.3本文的设计内容1.拟定主接线方案:依据原始资料,确定主变形式及规格型号,技术经济比较,确定最佳方案。选择各侧接线方式,确定所用电引接方式。2.计算短路电流:选择计算短路点,计算各点短路电流,并列出短电流计算结果表。3.选择主要电器设备:35kV、10kV主母线;选择主变10kV母线桥导体及绝缘子;
本文标题:35kV终端变电站
链接地址:https://www.777doc.com/doc-2919616 .html